An 80 gallon vertical ASME receiver stands roughly 63 to 66 inches tall and occupies about two feet by two feet of floor. That footprint is the reason to buy one. Shop sizes are normally stamped for 200 PSI, which covers anything you would put behind them.

Size storage off flow, not off the compressor's nameplate horsepower. Around 4 gallons of receiver per CFM is the working rule for a piston machine, and more if you have a big intermittent draw like a blast cabinet or a plasma table. The storage sizing article walks through the math. Storage is also the cheapest fix there is for a compressor that short cycles.

When to buy horizontal instead

Ceiling height and stability. If the receiver is going under a mezzanine, on a truck, on a skid, or anywhere a forklift can clip it, buy horizontal. A vertical tank with a pump and motor mounted on top gets tall in a hurry, and a 120 gallon vertical with a two stage pump on it will not clear a standard 8 foot door on a pallet. Measure the doorway and the ceiling before you order, not after it shows up on a truck.

The other thing people get wrong is the drain. A vertical tank funnels every bit of condensate into a few square inches at the very bottom, and that bottom is usually tucked behind the compressor where nobody can reach the petcock. Water sits, the tank rusts from the inside out, and the first warning sign is a wet floor. Put an automatic drain on it, or at minimum pipe the drain somewhere you will actually use it. Browse the full air compressor tank range for other sizes and mounting styles.