Skip to content

Collection: Duplex Two Stage Air Compressors

A duplex puts two pumps and two motors on one receiver. The point is not more air. It is that each pump is sized to carry the shop by itself, so a failed motor or a cracked valve plate costs you half your capacity instead of all of it.

Two stage pumps make 175 PSI. With an alternating control, each pump on a duplex runs about half the hours a single unit would doing the same work, which keeps both inside the 50 to 75 percent duty cycle a piston air compressor is built for. Discharge temperature stays down, the oil stays cleaner, and valve life roughly doubles.

Watch the electrical before anything else. Two 7.5 HP motors at 230V three phase draw about 22 amps each while running, and if both start at once the inrush will nuisance trip the main. The controller has to stagger the starts. Confirm the panel can carry both, because this is the detail that holds up an installation after the equipment is already on the floor.

A duplex is the wrong buy if you simply need more CFM and have no redundancy requirement. One larger compressor costs less up front, takes less floor space, and gives you half the maintenance points. Buy the duplex when downtime is the expensive thing, not when air is.

Size the receiver tank to the combined output, with 60 to 80 gallons per 5 HP pump as a starting point, and plan the drain for twice the condensate a simplex would make.