{"product_id":"champion-xchp-series-heated-purge-desiccant-air-dryer","title":"Champion XCHP Series Heated Purge Desiccant Air Dryer – External Heater Regeneration (150–1200 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion XCHP Series\u003c\/strong\u003e is an \u003cstrong\u003eX-Series twin-tower heated purge regenerative desiccant air dryer\u003c\/strong\u003e offered in ten capacities from \u003cstrong\u003e150 to 1200 SCFM\u003c\/strong\u003e, delivering a \u003cstrong\u003e-40°F (-40°C) pressure dew point\u003c\/strong\u003e at a maximum working pressure of \u003cstrong\u003e150 psig\u003c\/strong\u003e. An external heater conditions the regeneration air, so the XCHP restores its offline desiccant bed on a fraction of the compressed air a heatless dryer throws away. On a plant running two or three shifts, that reclaimed purge air is compressor horsepower you already paid to produce.\u003c\/p\u003e\u003cp\u003eEvery XCHP ships as a \u003cstrong\u003ecomplete filtered package\u003c\/strong\u003e with a coalescing prefilter and a particulate afterfilter already mounted and piped, NEMA 4 electrical enclosures, and a 460\/3\/60 power connection, so the dryer arrives ready to tie into the header without a separate filtration order.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your capacity and control package from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHeatless or Heated Purge: Where the XCHP Pays\u003c\/h2\u003e\u003cp\u003eEvery regenerative desiccant dryer has to get the water back out of the offline tower. A heatless dryer does it with pressure alone, expanding a slice of its own dried outlet air to atmosphere and sweeping it back through the bed. It is simple and dependable, and it is also why a heatless dryer consumes a meaningful percentage of its rated flow around the clock.\u003c\/p\u003e\u003cp\u003eThe XCHP puts an \u003cstrong\u003eexternal electric heater\u003c\/strong\u003e in that regeneration path. Hot purge air strips moisture out of the desiccant far more aggressively than ambient-temperature purge air, so the dryer needs much less of it to accomplish the same regeneration. You trade a modest electrical load for compressed air you stop venting, and at 150 SCFM and up that trade usually runs strongly in your favor.\u003c\/p\u003e\u003cp\u003eIf the heater ever faults, the controller drops the dryer into \u003cstrong\u003eheatless backup mode\u003c\/strong\u003e and keeps making -40°F air on pressure swing alone. You do not lose air quality waiting on a service call.\u003c\/p\u003e\u003cp\u003ePurge consumption varies by model, operating pressure and cycle, and Champion publishes it per configuration rather than as a single headline number. Send us your flow, pressure and run hours and we will put the XCHP, a heatless dryer and a blower purge dryer side by side on real numbers before you commit.\u003c\/p\u003e\n\n\u003ch2\u003eWhat Sets the XCHP Apart\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal heater regeneration\u003c\/strong\u003e: cuts the compressed air diverted to purge compared with a heatless design of the same capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatless backup mode\u003c\/strong\u003e: a heater fault does not take your dew point with it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-profile construction with operator-level valve access\u003c\/strong\u003e: the valves a technician actually services are at working height, not buried overhead or between the towers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-lubricated ball and butterfly switching valves\u003c\/strong\u003e: stainless steel internals and PTFE seats, with no lubrication to maintain and nothing to migrate downstream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital multi-function controller\u003c\/strong\u003e: backlit LCD readable in any light, continuous monitoring, stored failure codes, and Modbus communication for plant integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA 4 electrical enclosures standard\u003c\/strong\u003e: rated for indoor or outdoor installation with no enclosure upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrefilter and afterfilter mounted\u003c\/strong\u003e: the desiccant is protected from oil carryover and the downstream air from desiccant fines, out of the crate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge sound-attenuating purge mufflers\u003c\/strong\u003e with integral relief valves: the towers vent without making the mechanical room unbearable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable stainless steel desiccant screens\u003c\/strong\u003e: pull them, clean them, put them back, instead of replacing them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTower pressure gauges\u003c\/strong\u003e: confirm the dryer is cycling correctly from across the room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eChoosing Your Configuration\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eWhat You Get\u003c\/th\u003e\n\u003cth\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard -40°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed-cycle heated purge regeneration with the standard digital controller, NEMA 4 enclosures, and the mounted prefilter and afterfilter package. The dryer runs its regeneration cycle on a set schedule whether or not it is fully loaded.\u003c\/td\u003e\n\u003ctd\u003ePlants that run at or near steady compressed-air demand through the shift, where the dryer is loaded most of the hours it is powered.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Management System -40°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEverything in the standard unit plus dew point demand control with a digital display. The controller measures actual moisture loading and extends the drying cycle when the plant is light, so purge and heater energy track real demand instead of the clock.\u003c\/td\u003e\n\u003ctd\u003eAny plant with variable demand, multiple shifts or seasonal swing. The EMS premium is the single highest-leverage option on this dryer and typically pays back in energy alone.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3-Valve Bypass (with either control package)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA factory-piped bypass around the dryer and its filters, so the unit can be isolated, serviced or rebuilt without shutting the plant air header down.\u003c\/td\u003e\n\u003ctd\u003eAny system that cannot take a planned outage. Specify the bypass at time of order; retrofitting one in the field costs far more than the factory option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eRated Flow at -40°F\u003c\/th\u003e\n\u003cth\u003eInlet \/ Outlet Connection\u003c\/th\u003e\n\u003cth\u003eDimensions (W x D x H)\u003c\/th\u003e\n\u003cth\u003eShipping Weight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP150\u003c\/td\u003e\n\u003ctd\u003e150 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPT\u003c\/td\u003e\n\u003ctd\u003e44.5 x 32 x 66 in\u003c\/td\u003e\n\u003ctd\u003e758 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP200\u003c\/td\u003e\n\u003ctd\u003e200 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPT\u003c\/td\u003e\n\u003ctd\u003e48.5 x 32 x 67 in\u003c\/td\u003e\n\u003ctd\u003e913 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP250\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPT\u003c\/td\u003e\n\u003ctd\u003e52.5 x 35 x 68 in\u003c\/td\u003e\n\u003ctd\u003e1,119 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP300\u003c\/td\u003e\n\u003ctd\u003e300 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPT\u003c\/td\u003e\n\u003ctd\u003e52.5 x 35 x 68 in\u003c\/td\u003e\n\u003ctd\u003e1,191 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP400\u003c\/td\u003e\n\u003ctd\u003e400 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPT\u003c\/td\u003e\n\u003ctd\u003e56.5 x 34 x 82 in\u003c\/td\u003e\n\u003ctd\u003e1,539 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP500\u003c\/td\u003e\n\u003ctd\u003e500 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPT\u003c\/td\u003e\n\u003ctd\u003e56.5 x 34 x 82 in\u003c\/td\u003e\n\u003ctd\u003e1,707 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP600\u003c\/td\u003e\n\u003ctd\u003e600 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPT\u003c\/td\u003e\n\u003ctd\u003e64 x 47 x 86 in\u003c\/td\u003e\n\u003ctd\u003e2,369 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP800\u003c\/td\u003e\n\u003ctd\u003e800 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPT\u003c\/td\u003e\n\u003ctd\u003e64 x 47 x 86 in\u003c\/td\u003e\n\u003ctd\u003e2,681 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP1000\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPT\u003c\/td\u003e\n\u003ctd\u003e78.5 x 48 x 80 in\u003c\/td\u003e\n\u003ctd\u003e3,043 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP1200\u003c\/td\u003e\n\u003ctd\u003e1200 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPT\u003c\/td\u003e\n\u003ctd\u003e78.5 x 48 x 80 in\u003c\/td\u003e\n\u003ctd\u003e3,285 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eFlows are rated at -40°F pressure dew point at standard inlet conditions. Weights are Champion's published figures for the dryer. If you need certified general-arrangement drawings or a crated freight weight before you pour a pad or book a truck, ask us and we will pull them from the factory.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-40°F Pressure Dew Point\u003c\/strong\u003e: ISO 8573-1 humidity Class 2 on every model, with a -100°F (-73°C) factory option available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150 to 1200 SCFM\u003c\/strong\u003e: ten capacities covering a single large rotary screw through a full plant air header.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated Purge Regeneration\u003c\/strong\u003e: external heater conditions the purge air so far less compressed air leaves the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeatless Backup Mode\u003c\/strong\u003e: automatic fallback on a heater fault.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrefilter and Afterfilter Included\u003c\/strong\u003e: mounted and piped at the factory on every configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA 4 Enclosures Standard\u003c\/strong\u003e: indoor or outdoor service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Controller with Modbus\u003c\/strong\u003e: backlit LCD, continuous monitoring, stored failure codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150 PSIG Maximum Working Pressure\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e460\/3\/60 Power\u003c\/strong\u003e: 575V and CRN configurations available consult-factory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChampion Pneumatic Quality\u003c\/strong\u003e: a Gardner Denver brand with more than a century of compressed-air engineering behind it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDryer Type\u003c\/td\u003e\n\u003ctd\u003eTwin tower heated purge regenerative desiccant, externally heated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e150 to 1200 SCFM at -40°F pressure dew point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Dew Point\u003c\/td\u003e\n\u003ctd\u003e-40°F (-40°C) standard; -100°F (-73°C) factory option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e150 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e460\/3\/60 standard; 575V consult factory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 4 standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eDigital multi-function, backlit LCD, stored failure codes, Modbus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegeneration\u003c\/td\u003e\n\u003ctd\u003eExternally heated purge, with heatless backup mode on heater fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Valves\u003c\/td\u003e\n\u003ctd\u003eNon-lubricated ball and butterfly, stainless steel internals, PTFE seats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesiccant\u003c\/td\u003e\n\u003ctd\u003eActivated alumina, field replaceable, removable stainless steel support screens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltration\u003c\/td\u003e\n\u003ctd\u003eCoalescing prefilter and particulate afterfilter, factory mounted (XCHE and 4772 series elements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndication\u003c\/td\u003e\n\u003ctd\u003eTower pressure gauges; digital dew point display with the EMS option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003e1\" to 3\" NPT depending on capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Point\u003c\/td\u003e\n\u003ctd\u003eF.O.B. West Chester, PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eSpecify a heated purge desiccant dryer where you need a true -40°F dew point at a flow large enough that heatless purge air becomes an expensive habit: plant air headers at 150 SCFM and above, compressed air piping that runs outdoors or through unheated space and would otherwise freeze, spray finishing and powder coating lines, pneumatic instrumentation and control air, laser cutting assist gas, blow molding, pharmaceutical and food packaging, textile manufacturing, electronics assembly, and any breathing-air or critical process loop written to an ISO 8573-1 class. The XCHP is also the usual upgrade path for a plant that outgrew a heatless dryer and is now watching its purge air eat a compressor.\u003c\/p\u003e\n\n\u003ch2\u003eFactory Options\u003c\/h2\u003e\u003cp\u003eBeyond the control and bypass packages priced in the dropdowns above, the XCHP Series supports several factory-configured options quoted at time of order:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-100°F (-73°C) Dew Point\u003c\/strong\u003e: for ISO 8573-1 humidity Class 1 applications. Low dew point operation affects rated capacity, so let us confirm sizing with the factory rather than sizing off the model number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Tower Insulation\u003c\/strong\u003e: reduces heat loss from the regenerating tower and improves regeneration efficiency indoors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Humidity Alarm\u003c\/strong\u003e: alarms when outlet moisture rises above setpoint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Outlet Temperature Alarm\u003c\/strong\u003e: alarms on elevated outlet temperature during or after regeneration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e575V Power and CRN Registration\u003c\/strong\u003e: Canadian Registration Number and 575V configurations are consult-factory for part number, price and lead time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSend us your model and the options you need and we will quote the configured part number and current lead time.\u003c\/p\u003e\n\n\u003ch2\u003eMounted Filtration and Replacement Elements\u003c\/h2\u003e\u003cp\u003eEvery XCHP arrives with its prefilter and afterfilter installed. Change the elements annually, keep the drains working, and the desiccant bed will do its job for years. Element part numbers by dryer model:\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDryer Model\u003c\/th\u003e\n\u003cth\u003ePrefilter Element\u003c\/th\u003e\n\u003cth\u003eAfterfilter Element\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP150\u003c\/td\u003e\n\u003ctd\u003eXCHE235E\u003c\/td\u003e\n\u003ctd\u003e47723655002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP200\u003c\/td\u003e\n\u003ctd\u003eXCHE288E\u003c\/td\u003e\n\u003ctd\u003e47723656002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP250\u003c\/td\u003e\n\u003ctd\u003eXCHE288E\u003c\/td\u003e\n\u003ctd\u003e47723656002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP300\u003c\/td\u003e\n\u003ctd\u003eXCHE353E\u003c\/td\u003e\n\u003ctd\u003e47723656002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP400\u003c\/td\u003e\n\u003ctd\u003eXCHE589E\u003c\/td\u003e\n\u003ctd\u003e47723657002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP500\u003c\/td\u003e\n\u003ctd\u003eXCHE589E\u003c\/td\u003e\n\u003ctd\u003e47723657002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP600\u003c\/td\u003e\n\u003ctd\u003eXCHE1077E\u003c\/td\u003e\n\u003ctd\u003e47723658002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP800\u003c\/td\u003e\n\u003ctd\u003eXCHE1077E\u003c\/td\u003e\n\u003ctd\u003e47723658002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP1000\u003c\/td\u003e\n\u003ctd\u003eXCHE1077E\u003c\/td\u003e\n\u003ctd\u003e47723658002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHP1200\u003c\/td\u003e\n\u003ctd\u003eXCHE1354E\u003c\/td\u003e\n\u003ctd\u003e47723659002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eCall or email us with your dryer model and we will quote elements and a replacement desiccant charge, and tell you which ones are worth keeping on the shelf.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eSizing, Installation and Electrical\u003c\/h2\u003e\u003cp\u003eSize the dryer to the actual SCFM passing through it at your operating pressure, not to compressor nameplate horsepower, and size for the hottest, wettest day your compressor room sees rather than the average one. Install a properly sized \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/vertical-air-compressor-tanks\"\u003ewet receiver tank\u003c\/a\u003e ahead of the dryer with a working drain, keep inlet air temperature within specification, and leave service access on all sides for tower recharge and valve work.\u003c\/p\u003e\u003cp\u003eElectrically, the XCHP is a 460\/3\/60 machine with NEMA 4 enclosures. Heater and full-load electrical data vary by capacity and configuration, so we confirm the exact figures with the factory for your submittal before the order ships rather than having an electrician guess at the feeder. Our engineers will review your layout and your one-line at no charge.\u003c\/p\u003e\n\n\u003ch2\u003eDesiccant Life and Service\u003c\/h2\u003e\u003cp\u003eActivated alumina in a properly filtered dryer typically gives several years of service before the bed needs recharging. The fastest way to destroy a desiccant bed is oil carryover from an upstream compressor, which is exactly why the XCHP ships with a coalescing prefilter as standard equipment. Change the elements on schedule, keep the drain working, verify the tower changeover is completing, and the bed will last. Champion supports the XCHP with replacement elements, valve seal and actuator kits, mufflers and bulk activated alumina charges; we stock and quote all of it.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every XCHP Series dryer ships with full factory warranty, factory-direct freight from West Chester, and lifetime application support from our certified compressed-air engineers. We will size the dryer, quote the configured part number with the options you actually need, and stay with the job through startup.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat dew point does the XCHP deliver?\u003c\/h3\u003e\u003cp\u003e-40°F (-40°C) pressure dew point as standard, which corresponds to ISO 8573-1 humidity Class 2. A -100°F (-73°C) Class 1 configuration is available as a factory option and is quoted on request.\u003c\/p\u003e\n\u003ch3\u003eHeatless, heated purge or heated blower purge: which one do I need?\u003c\/h3\u003e\u003cp\u003eHeatless is the simplest and lowest capital cost, and below roughly 150 SCFM it is almost always the right answer. Heated purge, like this XCHP, adds an external heater so the dryer regenerates on much less compressed air, and it starts paying for itself as flow and run hours climb. Heated blower purge goes a step further by using ambient air moved by a blower instead of compressed air for most of the regeneration, at higher capital cost and more moving parts. If you are near the crossover, send us your flow, pressure, run hours and electricity rate and we will run the comparison rather than guess.\u003c\/p\u003e\n\u003ch3\u003eHow does the XCHP compare with the heatless XCHL?\u003c\/h3\u003e\u003cp\u003eBoth are X-Series twin tower dryers with mounted filtration, NEMA 4 enclosures and Modbus-capable digital controls. The \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xchl-series-heatless-desiccant-air-dryer\"\u003eXCHL Series\u003c\/a\u003e is heatless, costs less to buy, and has no heater to maintain. The XCHP costs more up front and gives most of that compressed air back. At 150 SCFM the gap is arguable; at 800 SCFM running three shifts it usually is not.\u003c\/p\u003e\n\u003ch3\u003eWhat happens if the heater fails?\u003c\/h3\u003e\u003cp\u003eThe controller switches the dryer to heatless backup mode and continues delivering -40°F air on pressure swing regeneration alone. Purge consumption rises until the heater is repaired, but your air quality does not drop.\u003c\/p\u003e\n\u003ch3\u003eDo I still need to buy filters?\u003c\/h3\u003e\u003cp\u003eNo. The prefilter and afterfilter are included and factory mounted on every configuration listed here. What you should not skip is a properly drained wet receiver upstream and diligent separator maintenance on an oil-flooded rotary screw. Oil is what kills desiccant.\u003c\/p\u003e\n\u003ch3\u003eWhat is the maximum working pressure?\u003c\/h3\u003e\u003cp\u003e150 psig. If your system runs above that, tell us and we will quote the correct platform instead.\u003c\/p\u003e\n\u003ch3\u003eWhat power does it need?\u003c\/h3\u003e\u003cp\u003e460\/3\/60 as standard, with NEMA 4 enclosures. 575V is a consult-factory configuration. We confirm heater rating and full-load amps with the factory for your electrical submittal before the unit ships.\u003c\/p\u003e\n\u003ch3\u003eShould I add the Energy Management System?\u003c\/h3\u003e\u003cp\u003eOn almost any plant with variable demand, yes. EMS measures actual moisture loading and extends the drying cycle when the dryer is lightly loaded, so purge air and heater energy follow real demand instead of a fixed timer. It is the option that most often pays for itself, and it is the one customers most often wish they had specified.\u003c\/p\u003e\n\u003ch3\u003eWhat is the warranty?\u003c\/h3\u003e\u003cp\u003eThe XCHP falls under Champion's X-Series warranty statement. Ask us for the current statement and for extended coverage pricing on your model.\u003c\/p\u003e\n\u003ch3\u003eHow long does delivery take?\u003c\/h3\u003e\u003cp\u003eLead time depends on capacity and options. Call us with your model and we will confirm the current factory schedule before you place the order.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"150 SCFM \/ Standard -40°F","offer_id":54743273439507,"sku":"XCHP1504H000A","price":22824.99,"currency_code":"USD","in_stock":true},{"title":"150 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743273472275,"sku":"XCHP1504H000H","price":24112.89,"currency_code":"USD","in_stock":true},{"title":"150 SCFM \/ Energy Management System -40°F","offer_id":54743273505043,"sku":"XCHP1504HN00A","price":29119.5,"currency_code":"USD","in_stock":true},{"title":"150 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743273537811,"sku":"XCHP1504HN00H","price":30404.16,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Standard -40°F","offer_id":54743273570579,"sku":"XCHP2004H000A","price":26460.27,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743273603347,"sku":"XCHP2004H000H","price":28716.93,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Energy Management System -40°F","offer_id":54743273636115,"sku":"XCHP2004HN00A","price":32755.59,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743273668883,"sku":"XCHP2004HN00H","price":35010.63,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Standard -40°F","offer_id":54743273701651,"sku":"XCHP2504H000A","price":27902.07,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743273734419,"sku":"XCHP2504H000H","price":30157.11,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Energy Management System -40°F","offer_id":54743273767187,"sku":"XCHP2504HN00A","price":34194.15,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743273799955,"sku":"XCHP2504HN00H","price":36449.19,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Standard -40°F","offer_id":54743273832723,"sku":"XCHP3004H000A","price":29388.42,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743273865491,"sku":"XCHP3004H000H","price":31641.03,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Energy Management System -40°F","offer_id":54743273898259,"sku":"XCHP3004HN00A","price":35679.69,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743273931027,"sku":"XCHP3004HN00H","price":37934.73,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Standard -40°F","offer_id":54743273963795,"sku":"XCHP4004H000A","price":31775.49,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743273996563,"sku":"XCHP4004H000H","price":34106.67,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Energy Management System -40°F","offer_id":54743274029331,"sku":"XCHP4004HN00A","price":40350.96,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743274062099,"sku":"XCHP4004HN00H","price":40399.56,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Standard -40°F","offer_id":54743274094867,"sku":"XCHP5004H000A","price":36690.57,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743274127635,"sku":"XCHP5004H000H","price":39023.37,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Energy Management System -40°F","offer_id":54743274160403,"sku":"XCHP5004HN00A","price":42983.46,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743274193171,"sku":"XCHP5004HN00H","price":45315.45,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Standard -40°F","offer_id":54743274225939,"sku":"XCHP6004H000A","price":41160.15,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743274258707,"sku":"XCHP6004H000H","price":44045.37,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Energy Management System -40°F","offer_id":54743274291475,"sku":"XCHP6004HN00A","price":47451.42,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743274324243,"sku":"XCHP6004HN00H","price":49409.19,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Standard -40°F","offer_id":54743274357011,"sku":"XCHP8004H000A","price":50174.64,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743274389779,"sku":"XCHP8004H000H","price":55863.27,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Energy Management System -40°F","offer_id":54743274422547,"sku":"XCHP8004HN00A","price":56469.15,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743274455315,"sku":"XCHP8004HN00H","price":62159.4,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Standard -40°F","offer_id":54743274488083,"sku":"XCHP10004H000A","price":56887.92,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743274520851,"sku":"XCHP10004H000H","price":62578.17,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Energy Management System -40°F","offer_id":54743274553619,"sku":"XCHP10004HN00A","price":63180.81,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743274586387,"sku":"XCHP10004HN00H","price":68869.44,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Standard -40°F","offer_id":54743274619155,"sku":"XCHP12004H000A","price":61560.81,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54743274651923,"sku":"XCHP12004H000H","price":67251.87,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Energy Management System -40°F","offer_id":54743274684691,"sku":"XCHP12004HN00A","price":67854.51,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54743274717459,"sku":"XCHP12004HN00H","price":73545.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/champion-xchp-heated-purge-desiccant-dryer.jpg?v=1789730227","url":"https:\/\/aircompressorstore.com\/products\/champion-xchp-series-heated-purge-desiccant-air-dryer","provider":"Warthog Air Compressor Store","version":"1.0","type":"link"}