{"product_id":"champion-xchl-series-heatless-desiccant-air-dryer","title":"Champion XCHL Series Heatless Desiccant Air Dryer – Low-Profile Twin Tower with Filtration (90–1200 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion XCHL Series\u003c\/strong\u003e is an \u003cstrong\u003eX-Series twin-tower heatless regenerative desiccant air dryer\u003c\/strong\u003e offered in twelve capacities from \u003cstrong\u003e90 to 1200 SCFM\u003c\/strong\u003e, delivering a \u003cstrong\u003e-40°F pressure dew point\u003c\/strong\u003e as standard and \u003cstrong\u003e-100°F\u003c\/strong\u003e as a factory option. Where a \u003ca href='\"https:\/\/aircompressorstore.com\/collections\/refrigerated-air-dryers\"'\u003erefrigerated air dryer\u003c\/a\u003e stops around a 35°F to 40°F dew point, the XCHL strips water vapor out of the air stream entirely, which is what outdoor piping, paint booths, instrument air loops and ISO 8573-1 process specifications actually require.\u003c\/p\u003e\u003cp\u003eEvery XCHL ships as a \u003cstrong\u003ecomplete filtered package\u003c\/strong\u003e with a high-efficiency coalescing prefilter and a particulate afterfilter already mounted and piped, so the dryer arrives ready to tie into the header without a separate filtration order.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your capacity and control package from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhat Sets the XCHL Apart\u003c\/h2\u003e\u003cp\u003eThe XCHL is Champion's low-profile heatless platform, and the design decisions all point the same direction: fit it in a real mechanical room and make it easy to service.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-profile cabinet\u003c\/strong\u003e: the towers are proportioned so the dryer drops into spaces with restricted overhead clearance, from 63 inches tall at 90 SCFM to 87.6 inches at 1200 SCFM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear-mounted inlet and outlet manifolds\u003c\/strong\u003e: the switching and purge valves sit where a technician can actually reach them instead of buried between the towers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-life switching and purge valves\u003c\/strong\u003e: extended service intervals on the parts that do the cycling work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA 4 electrical enclosure standard\u003c\/strong\u003e: rated for indoor or outdoor installation with no enclosure upgrade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital controller with backlit LCD\u003c\/strong\u003e: precise pneumatic valve sequencing, maintenance reminders at the preventive service intervals, and Modbus communication through the controller's RS-485 port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor-change moisture indicator and tower pressure gauges\u003c\/strong\u003e: you can confirm the dryer is doing its job from across the room.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow Heatless Regenerative Drying Works\u003c\/h2\u003e\u003cp\u003eA heatless desiccant dryer runs two towers packed with high-strength activated alumina. Wet compressed air flows up through the online tower, where the desiccant bed adsorbs water vapor and releases air at a -40°F pressure dew point. A small fraction of that dried air is then expanded to atmosphere and swept back down through the offline tower, stripping moisture out of the spent desiccant and regenerating the bed. The towers alternate, so one is always drying while the other recovers.\u003c\/p\u003e\u003cp\u003eThere is no heater, no blower and no moving part in the air path beyond the switching valves. That is why heatless designs remain the most reliable and lowest-maintenance route to a -40°F dew point. The trade-off is purge air, and reclaiming that purge air is exactly what the Energy Management System option exists to do.\u003c\/p\u003e\u003ch2\u003eChoosing Your Configuration\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eWhat You Get\u003c\/th\u003e\n\u003cth\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard -40°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed-cycle timed tower changeover with the standard digital controller, NEMA 4 enclosure, and the mounted prefilter and afterfilter package. Purge air is consumed on a set cycle whether or not the dryer is loaded.\u003c\/td\u003e\n\u003ctd\u003ePlants that run at or near full compressed-air demand through the shift, where the dryer is loaded most of the hours it is powered.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Management System -40°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEverything in the standard unit plus dew point demand control with a digital dew point display. The controller measures actual moisture loading and extends the drying cycle when the plant is light, cutting purge air to match real demand.\u003c\/td\u003e\n\u003ctd\u003eAny plant with variable demand, multiple shifts or seasonal swing. Purge air a timed dryer throws away is compressor horsepower you already paid for, and the EMS premium typically pays back in energy alone.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Management System -100°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe EMS unit built for a \u003cstrong\u003e-100°F (-73°C) pressure dew point\u003c\/strong\u003e, ISO 8573-1 humidity Class 1. Note that -100°F operation derates rated flow by 20 percent, so size from the -100°F column in the chart below.\u003c\/td\u003e\n\u003ctd\u003eBreathing air, laser assist gas, critical instrumentation, pharmaceutical and electronics processes written to a Class 1 specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3-Valve Bypass (any of the above)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA factory-piped bypass around the dryer and filters, so the dryer can be isolated, serviced or rebuilt without shutting the plant air header down.\u003c\/td\u003e\n\u003ctd\u003eAny system that cannot take a planned outage. Specify the bypass at time of order; retrofitting it in the field costs far more.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eRated Flow at -40°F\u003c\/th\u003e\n\u003cth\u003eRated Flow at -100°F\u003c\/th\u003e\n\u003cth\u003eInlet Connection\u003c\/th\u003e\n\u003cth\u003eDimensions (H x W x D)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL90\u003c\/td\u003e\n\u003ctd\u003e90 SCFM\u003c\/td\u003e\n\u003ctd\u003e72 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPT\u003c\/td\u003e\n\u003ctd\u003e63.1 x 40.5 x 30.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL120\u003c\/td\u003e\n\u003ctd\u003e120 SCFM\u003c\/td\u003e\n\u003ctd\u003e96 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPT\u003c\/td\u003e\n\u003ctd\u003e63.1 x 40.6 x 30.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL160\u003c\/td\u003e\n\u003ctd\u003e160 SCFM\u003c\/td\u003e\n\u003ctd\u003e128 SCFM\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\" NPT\u003c\/td\u003e\n\u003ctd\u003e66.1 x 44.5 x 32.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL200\u003c\/td\u003e\n\u003ctd\u003e200 SCFM\u003c\/td\u003e\n\u003ctd\u003e160 SCFM\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\" NPT\u003c\/td\u003e\n\u003ctd\u003e66.1 x 44.5 x 32.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL250\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e200 SCFM\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\" NPT\u003c\/td\u003e\n\u003ctd\u003e66.8 x 48.5 x 32.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL300\u003c\/td\u003e\n\u003ctd\u003e300 SCFM\u003c\/td\u003e\n\u003ctd\u003e240 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPT\u003c\/td\u003e\n\u003ctd\u003e66.8 x 48.5 x 33.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL400\u003c\/td\u003e\n\u003ctd\u003e400 SCFM\u003c\/td\u003e\n\u003ctd\u003e320 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPT\u003c\/td\u003e\n\u003ctd\u003e67.8 x 52.5 x 35.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL500\u003c\/td\u003e\n\u003ctd\u003e500 SCFM\u003c\/td\u003e\n\u003ctd\u003e400 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPT\u003c\/td\u003e\n\u003ctd\u003e82.5 x 56.5 x 38.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL600\u003c\/td\u003e\n\u003ctd\u003e600 SCFM\u003c\/td\u003e\n\u003ctd\u003e480 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPT\u003c\/td\u003e\n\u003ctd\u003e82.5 x 56.5 x 38.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL800\u003c\/td\u003e\n\u003ctd\u003e800 SCFM\u003c\/td\u003e\n\u003ctd\u003e640 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPT\u003c\/td\u003e\n\u003ctd\u003e87.6 x 64.0 x 51.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL1000\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e800 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPT\u003c\/td\u003e\n\u003ctd\u003e87.6 x 64.0 x 51.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL1200\u003c\/td\u003e\n\u003ctd\u003e1200 SCFM\u003c\/td\u003e\n\u003ctd\u003e960 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPT\u003c\/td\u003e\n\u003ctd\u003e87.6 x 64.0 x 51.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eThe -100°F column is the 20 percent flow derate Champion applies to low dew point operation, so nobody sizes a dryer off the model number alone. Champion does not publish a shipping weight for the XCHL Series in the current price list; ask us and we will confirm crated weight and a certified general-arrangement drawing with the factory before you pour a pad or book freight.\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eThe 200 SCFM unit in standard timed-control trim, part number XCHL2001H00AA, is quoted on request rather than listed here because of a printing conflict in the current price list. Call or email us for that one configuration and we will confirm list price with the factory the same day. All other 200 SCFM configurations are priced above.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-40°F Pressure Dew Point Standard\u003c\/strong\u003e: ISO 8573-1 humidity Class 2 on every model, with -100°F Class 1 available as a factory option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e90 to 1200 SCFM\u003c\/strong\u003e: twelve capacities spanning a single 20 HP rotary screw through a full plant air header.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrefilter and Afterfilter Included\u003c\/strong\u003e: high-efficiency coalescing prefilter and particulate afterfilter mounted and piped at the factory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Profile Design\u003c\/strong\u003e: fits installations with limited overhead clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA 4 Enclosure Standard\u003c\/strong\u003e: suitable for indoor and outdoor service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Digital Controller\u003c\/strong\u003e: backlit LCD, precise valve sequencing, maintenance reminders, Modbus over RS-485.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Life Valves\u003c\/strong\u003e: switching and purge valves designed for extended service intervals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDownstream Purge Standard\u003c\/strong\u003e: the standard purge arrangement on every listed configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Strength Activated Alumina\u003c\/strong\u003e: field-replaceable desiccant with a color-change moisture indicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChampion Pneumatic Quality\u003c\/strong\u003e: a Gardner Denver brand with more than a century of compressed-air engineering behind it.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDryer Type\u003c\/td\u003e\n\u003ctd\u003eTwin tower heatless regenerative desiccant, pressure swing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e90 to 1200 SCFM at -40°F; 72 to 960 SCFM at -100°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Dew Point\u003c\/td\u003e\n\u003ctd\u003e-40°F (-40°C) standard; -100°F (-73°C) optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesiccant\u003c\/td\u003e\n\u003ctd\u003eHigh-strength activated alumina, field replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e115\/1\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 4 standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController\u003c\/td\u003e\n\u003ctd\u003eDigital with backlit LCD display, maintenance reminders, valve sequencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus via RS-485 standard; Ethernet optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurge Arrangement\u003c\/td\u003e\n\u003ctd\u003eDownstream purge (standard on all listed configurations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltration\u003c\/td\u003e\n\u003ctd\u003eHigh-efficiency prefilter and afterfilter, factory mounted (XCHE and XCGP elements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndication\u003c\/td\u003e\n\u003ctd\u003eTower pressure gauges and color-change moisture indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Connections\u003c\/td\u003e\n\u003ctd\u003e1\" to 3\" NPT depending on capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Point\u003c\/td\u003e\n\u003ctd\u003eF.O.B. West Chester, PA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eSpecify a heatless desiccant dryer anywhere a 35°F refrigerated dew point is not good enough: compressed air piping that runs outdoors or through unheated space and would otherwise freeze, spray finishing and powder coating, pneumatic instrumentation and control air, laser cutting assist gas, dental and laboratory air, blow molding, pharmaceutical and food packaging, textile manufacturing, electronics assembly, and any breathing-air or critical process loop written to an ISO 8573-1 class. The XCHL is also the usual answer for a plant that already installed a refrigerated dryer and is still finding water at the tool.\u003c\/p\u003e\u003ch2\u003eFactory Options\u003c\/h2\u003e\u003cp\u003eBeyond the control, dew point and bypass packages priced above, the XCHL Series supports several factory-configured options quoted at time of order:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-to-Shift Alarm\u003c\/strong\u003e: electronic pressure monitoring that alarms if a tower does not complete its changeover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Connectivity\u003c\/strong\u003e: adds Ethernet to the standard Modbus RS-485 for plant monitoring integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Control Air Tubing\u003c\/strong\u003e: for corrosive or wash-down environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Tower Insulation\u003c\/strong\u003e and \u003cstrong\u003ehigh humidity or high outlet alarms\u003c\/strong\u003e: available on the heated Champion platforms and quoted case by case on the XCHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCRN Registration\u003c\/strong\u003e: Canadian Registration Number configurations are consult-factory for part number, price and lead time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSend us your model and the options you need and we will quote the configured part number and current lead time.\u003c\/p\u003e\u003ch2\u003eSizing, Purge and Installation\u003c\/h2\u003e\u003cp\u003eSize the dryer to the actual SCFM passing through it at your operating pressure, not to compressor nameplate horsepower, and remember that a heatless dryer consumes purge air from the system it is drying. Plan for roughly 15 percent of rated flow on a timed unit at full cycle, which is precisely the number the Energy Management System exists to reduce when the plant is running light. If your compressor has no headroom, either step the dryer up a size or specify EMS.\u003c\/p\u003e\u003cp\u003eIf you are specifying a -100°F unit, size from the -100°F column: an XCHL500 at -100°F is a 400 SCFM dryer.\u003c\/p\u003e\u003cp\u003eInstall a properly sized \u003ca href='\"https:\/\/aircompressorstore.com\/collections\/vertical-air-compressor-tanks\"'\u003ewet receiver tank\u003c\/a\u003e upstream of the dryer, keep inlet air temperature within specification, and leave service access on all sides for tower recharge and valve work. Our engineers will review your layout at no charge.\u003c\/p\u003e\u003ch2\u003eService Kits and Desiccant Life\u003c\/h2\u003e\u003cp\u003eActivated alumina in a properly filtered heatless dryer typically gives three to five years before the bed needs recharging. The fastest way to destroy a desiccant bed is oil carryover from an upstream compressor, which is why the XCHL ships with a coalescing prefilter as standard equipment. Change the XCHE and XCGP elements annually, keep the drain working, and the bed will last.\u003c\/p\u003e\u003cp\u003eChampion publishes a scheduled service kit program for the XCHL. Kit contents by year:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYear 1 and Year 3\u003c\/strong\u003e: XCHE and XCGP elements, control air element, float drain, muffler, desiccant test kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYear 2 and Year 4\u003c\/strong\u003e: all Year 1 and 3 contents plus valve inlet seal kit, valve inlet actuator, valve purge seal kit, valve purge actuator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYear 5\u003c\/strong\u003e: all Year 1 and 3 contents plus BMI and a full desiccant charge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eYear 1 and 3 Kit\u003c\/th\u003e\n\u003cth\u003eYear 2 and 4 Kit\u003c\/th\u003e\n\u003cth\u003eYear 5 Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL90\u003c\/td\u003e\n\u003ctd\u003e47738304001\u003c\/td\u003e\n\u003ctd\u003e47738304002\u003c\/td\u003e\n\u003ctd\u003e47738304003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL120\u003c\/td\u003e\n\u003ctd\u003e47738304004\u003c\/td\u003e\n\u003ctd\u003e47738304005\u003c\/td\u003e\n\u003ctd\u003e47738304006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL160\u003c\/td\u003e\n\u003ctd\u003e47738304007\u003c\/td\u003e\n\u003ctd\u003e47738304008\u003c\/td\u003e\n\u003ctd\u003e47738304009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL200\u003c\/td\u003e\n\u003ctd\u003e47738304010\u003c\/td\u003e\n\u003ctd\u003e47738304011\u003c\/td\u003e\n\u003ctd\u003e47738304012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL250\u003c\/td\u003e\n\u003ctd\u003e47738304013\u003c\/td\u003e\n\u003ctd\u003e47738304014\u003c\/td\u003e\n\u003ctd\u003e47738304015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL300\u003c\/td\u003e\n\u003ctd\u003e47738304016\u003c\/td\u003e\n\u003ctd\u003e47738304017\u003c\/td\u003e\n\u003ctd\u003e47738304018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL400\u003c\/td\u003e\n\u003ctd\u003e47738304019\u003c\/td\u003e\n\u003ctd\u003e47738304020\u003c\/td\u003e\n\u003ctd\u003e47738304021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL500\u003c\/td\u003e\n\u003ctd\u003e47738304022\u003c\/td\u003e\n\u003ctd\u003e47738304023\u003c\/td\u003e\n\u003ctd\u003e47738304024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL600\u003c\/td\u003e\n\u003ctd\u003e47738304025\u003c\/td\u003e\n\u003ctd\u003e47738304026\u003c\/td\u003e\n\u003ctd\u003e47738304027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL800\u003c\/td\u003e\n\u003ctd\u003e47738304028\u003c\/td\u003e\n\u003ctd\u003e47738304029\u003c\/td\u003e\n\u003ctd\u003e47738304030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL1000\u003c\/td\u003e\n\u003ctd\u003e47738304031\u003c\/td\u003e\n\u003ctd\u003e47738304032\u003c\/td\u003e\n\u003ctd\u003e47738304033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCHL1200\u003c\/td\u003e\n\u003ctd\u003e47738304034\u003c\/td\u003e\n\u003ctd\u003e47738304035\u003c\/td\u003e\n\u003ctd\u003e47738304036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eChampion quotes the XCHL service kits factory-direct rather than publishing a list price. Send us your model and the kit year and we will price it and confirm availability.\u003c\/em\u003e\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every XCHL Series dryer ships with full factory warranty, factory-direct freight from West Chester, and lifetime application support from our certified compressed-air engineers. We will size the dryer, quote the configured part number with the options you need, and stay with the job through startup.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat dew point does the XCHL deliver?\u003c\/h3\u003e\u003cp\u003e-40°F pressure dew point as standard, which corresponds to ISO 8573-1 humidity Class 2. The -100°F (-73°C) configurations reach Class 1 and are priced in the dropdown above.\u003c\/p\u003e\u003ch3\u003eWhy does the -100°F version have less capacity?\u003c\/h3\u003e\u003cp\u003eReaching a -100°F dew point requires a longer contact time with the desiccant bed, so Champion derates rated flow by 20 percent. An XCHL1000 rated 1000 SCFM at -40°F is an 800 SCFM dryer at -100°F. The model selection chart above lists both numbers side by side.\u003c\/p\u003e\u003ch3\u003eXCHL or CDT: which heatless dryer should I buy?\u003c\/h3\u003e\u003cp\u003eBoth are twin-tower heatless dryers with filtration included. The \u003ca href='\"https:\/\/aircompressorstore.com\/products\/champion-cdt-series-heatless-desiccant-air-dryer\"'\u003eCDT Series\u003c\/a\u003e starts lower at 40 SCFM and tops out at 1350 SCFM, ships F.O.B. Ocala, and offers a 250 PSIG high-pressure package. The XCHL is the low-profile X-Series platform with rear-mounted manifolds, a -100°F factory option, and Modbus communication standard. If overhead clearance is tight or you need a Class 1 dew point, the XCHL is the better fit. Send us your flow, pressure and room layout and we will tell you straight.\u003c\/p\u003e\u003ch3\u003eHeatless, heated purge or blower purge?\u003c\/h3\u003e\u003cp\u003eHeatless is the simplest, most reliable and lowest capital cost, and it is the right answer for the large majority of industrial systems in this flow range. Heated purge and heated blower designs cut purge air consumption further and start to make economic sense at larger flows or where compressed air is unusually expensive to produce. If you are near the crossover, send us your flow, pressure and run hours and we will run the numbers.\u003c\/p\u003e\u003ch3\u003eDo I still need to buy filters?\u003c\/h3\u003e\u003cp\u003eNo. The prefilter and afterfilter are included and factory mounted on every configuration listed here. What you should not skip is a properly drained wet receiver upstream and diligent separator maintenance on an oil-flooded rotary screw. Oil is what kills desiccant.\u003c\/p\u003e\u003ch3\u003eHow much purge air does it use?\u003c\/h3\u003e\u003cp\u003ePlan on approximately 15 percent of rated flow at full cycle on a timed unit. The Energy Management System reduces that in proportion to how lightly loaded the dryer actually is.\u003c\/p\u003e\u003ch3\u003eWhat maximum working pressure is the XCHL rated for?\u003c\/h3\u003e\u003cp\u003eChampion does not publish a maximum working pressure figure for the XCHL Series in the current price list. Send us your operating pressure and we will confirm the correct configuration with the factory before you order.\u003c\/p\u003e\u003ch3\u003eWhat is the warranty?\u003c\/h3\u003e\u003cp\u003eThe XCHL falls under Champion's X-Series warranty statement: one year standard, with extended coverage available out to five years total including parts and labor. Ask us for the current statement and the extended coverage pricing for your model.\u003c\/p\u003e\u003ch3\u003eHow long does delivery take?\u003c\/h3\u003e\u003cp\u003eLead time depends on capacity and options. Call us with your model and we will confirm the current factory schedule before you place the order.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"90 SCFM \/ Standard -40°F","offer_id":54728760361235,"sku":"XCHL901H00AA","price":11692.35,"currency_code":"USD","in_stock":true},{"title":"90 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728760394003,"sku":"XCHL901H00AH","price":12904.92,"currency_code":"USD","in_stock":true},{"title":"90 SCFM \/ Energy Management System -40°F","offer_id":54728760426771,"sku":"XCHL901HE0AA","price":17407.71,"currency_code":"USD","in_stock":true},{"title":"90 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728760459539,"sku":"XCHL901HE0AH","price":18619.47,"currency_code":"USD","in_stock":true},{"title":"90 SCFM \/ Energy Management System -100°F","offer_id":54728760492307,"sku":"XCHL90BHE0AA","price":18688.32,"currency_code":"USD","in_stock":true},{"title":"90 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728760525075,"sku":"XCHL90BHE0AH","price":19899.27,"currency_code":"USD","in_stock":true},{"title":"120 SCFM \/ Standard -40°F","offer_id":54728760557843,"sku":"XCHL1201H00AA","price":12402.72,"currency_code":"USD","in_stock":true},{"title":"120 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728760590611,"sku":"XCHL1201H00AH","price":13613.67,"currency_code":"USD","in_stock":true},{"title":"120 SCFM \/ Energy Management System -40°F","offer_id":54728760623379,"sku":"XCHL1201HE0AA","price":18119.7,"currency_code":"USD","in_stock":true},{"title":"120 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728760656147,"sku":"XCHL1201HE0AH","price":19330.65,"currency_code":"USD","in_stock":true},{"title":"120 SCFM \/ Energy Management System -100°F","offer_id":54728760688915,"sku":"XCHL120BHE0AA","price":19397.07,"currency_code":"USD","in_stock":true},{"title":"120 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728760721683,"sku":"XCHL120BHE0AH","price":20693.07,"currency_code":"USD","in_stock":true},{"title":"160 SCFM \/ Standard -40°F","offer_id":54728760754451,"sku":"XCHL1601H00AA","price":13817.79,"currency_code":"USD","in_stock":true},{"title":"160 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728760787219,"sku":"XCHL1601H00AH","price":15849.27,"currency_code":"USD","in_stock":true},{"title":"160 SCFM \/ Energy Management System -40°F","offer_id":54728760819987,"sku":"XCHL1601HE0AA","price":19533.96,"currency_code":"USD","in_stock":true},{"title":"160 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728760852755,"sku":"XCHL1601HE0AH","price":21076.2,"currency_code":"USD","in_stock":true},{"title":"160 SCFM \/ Energy Management System -100°F","offer_id":54728760885523,"sku":"XCHL160BHE0AA","price":20813.76,"currency_code":"USD","in_stock":true},{"title":"160 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728760918291,"sku":"XCHL160BHE0AH","price":23083.38,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728760951059,"sku":"XCHL2001H00AH","price":16698.15,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Energy Management System -40°F","offer_id":54728760983827,"sku":"XCHL2001HE0AA","price":20382.03,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728761016595,"sku":"XCHL2001HE0AH","price":21925.89,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Energy Management System -100°F","offer_id":54728761049363,"sku":"XCHL200BHE0AA","price":21662.64,"currency_code":"USD","in_stock":true},{"title":"200 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728761082131,"sku":"XCHL200BHE0AH","price":24086.16,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Standard -40°F","offer_id":54728761114899,"sku":"XCHL2501H00AA","price":16023.42,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728761147667,"sku":"XCHL2501H00AH","price":18055.71,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Energy Management System -40°F","offer_id":54728761180435,"sku":"XCHL2501HE0AA","price":21737.97,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728761213203,"sku":"XCHL2501HE0AH","price":23282.64,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Energy Management System -100°F","offer_id":54728761245971,"sku":"XCHL250BHE0AA","price":23016.96,"currency_code":"USD","in_stock":true},{"title":"250 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728761278739,"sku":"XCHL250BHE0AH","price":25455.06,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Standard -40°F","offer_id":54728761311507,"sku":"XCHL3001H00AA","price":17608.59,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728761344275,"sku":"XCHL3001H00AH","price":20544.84,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Energy Management System -40°F","offer_id":54728761377043,"sku":"XCHL3001HE0AA","price":23323.14,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728761409811,"sku":"XCHL3001HE0AH","price":24867.81,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Energy Management System -100°F","offer_id":54728761442579,"sku":"XCHL300BHE0AA","price":24602.94,"currency_code":"USD","in_stock":true},{"title":"300 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728761475347,"sku":"XCHL300BHE0AH","price":28151.55,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Standard -40°F","offer_id":54728761508115,"sku":"XCHL4001H00AA","price":20438.73,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728761540883,"sku":"XCHL4001H00AH","price":23374.98,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Energy Management System -40°F","offer_id":54728761573651,"sku":"XCHL4001HE0AA","price":26154.9,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728761606419,"sku":"XCHL4001HE0AH","price":27695.52,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Energy Management System -100°F","offer_id":54728761639187,"sku":"XCHL400BHE0AA","price":27435.51,"currency_code":"USD","in_stock":true},{"title":"400 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728761671955,"sku":"XCHL400BHE0AH","price":30582.36,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Standard -40°F","offer_id":54728761704723,"sku":"XCHL5001H00AA","price":23549.94,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728761737491,"sku":"XCHL5001H00AH","price":26487.0,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Energy Management System -40°F","offer_id":54728761770259,"sku":"XCHL5001HE0AA","price":29266.92,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728761803027,"sku":"XCHL5001HE0AH","price":30809.97,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Energy Management System -100°F","offer_id":54728761835795,"sku":"XCHL500BHE0AA","price":30545.91,"currency_code":"USD","in_stock":true},{"title":"500 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728761868563,"sku":"XCHL500BHE0AH","price":34893.99,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Standard -40°F","offer_id":54728761901331,"sku":"XCHL6001H00AA","price":26851.5,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728761934099,"sku":"XCHL6001H00AH","price":29788.56,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Energy Management System -40°F","offer_id":54728761966867,"sku":"XCHL6001HE0AA","price":32568.48,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728761999635,"sku":"XCHL6001HE0AH","price":34110.72,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Energy Management System -100°F","offer_id":54728762032403,"sku":"XCHL600BHE0AA","price":33846.66,"currency_code":"USD","in_stock":true},{"title":"600 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728762065171,"sku":"XCHL600BHE0AH","price":38501.73,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Standard -40°F","offer_id":54728762097939,"sku":"XCHL8001H00AA","price":31300.83,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728762130707,"sku":"XCHL8001H00AH","price":36567.45,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Energy Management System -40°F","offer_id":54728762163475,"sku":"XCHL8001HE0AA","price":37014.57,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728762196243,"sku":"XCHL8001HE0AH","price":40101.48,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Energy Management System -100°F","offer_id":54728762229011,"sku":"XCHL800BHE0AA","price":38990.97,"currency_code":"USD","in_stock":true},{"title":"800 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728762261779,"sku":"XCHL800BHE0AH","price":46195.92,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Standard -40°F","offer_id":54728762294547,"sku":"XCHL10001H00AA","price":37085.04,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728762327315,"sku":"XCHL10001H00AH","price":42351.66,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Energy Management System -40°F","offer_id":54728762360083,"sku":"XCHL10001HE0AA","price":42798.78,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728762392851,"sku":"XCHL10001HE0AH","price":45884.07,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Energy Management System -100°F","offer_id":54728762425619,"sku":"XCHL1000BHE0AA","price":44776.8,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728762458387,"sku":"XCHL1000BHE0AH","price":52512.3,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Standard -40°F","offer_id":54728762491155,"sku":"XCHL12001H00AA","price":41943.42,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Standard -40°F with 3-Valve Bypass","offer_id":54728762523923,"sku":"XCHL12001H00AH","price":47210.04,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Energy Management System -40°F","offer_id":54728762556691,"sku":"XCHL12001HE0AA","price":47658.78,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Energy Management System -40°F with 3-Valve Bypass","offer_id":54728762589459,"sku":"XCHL12001HE0AH","price":50743.26,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Energy Management System -100°F","offer_id":54728762622227,"sku":"XCHL1200BHE0AA","price":49634.37,"currency_code":"USD","in_stock":true},{"title":"1200 SCFM \/ Energy Management System -100°F with 3-Valve Bypass","offer_id":54728762654995,"sku":"XCHL1200BHE0AH","price":57825.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/XCHL-Series.jpg?v=1789643891","url":"https:\/\/aircompressorstore.com\/products\/champion-xchl-series-heatless-desiccant-air-dryer","provider":"Warthog Air Compressor Store","version":"1.0","type":"link"}