{"product_id":"champion-dri-series-point-of-use-drop-assembly","title":"Champion DRI Series Point-of-Use Drop Assembly – Water Remover, Lockable Valve and 4-Port Manifold","description":"\u003cp\u003eA proper point of use is three things at once: air that is dry where the tool is, a way to lock the drop out before anyone puts a wrench on it, and enough outlets that the next person does not tee into your line with a hose barb. The \u003cstrong\u003eChampion DRI drop assembly\u003c\/strong\u003e is all three, pre-built on one bracket. \u003cstrong\u003eDistribute. Remove. Isolate.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the configuration and port size from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eThe Four Configurations\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eWater Remover\u003c\/th\u003e\n\u003cth\u003eLockable Valve\u003c\/th\u003e\n\u003cth\u003e4-Port Manifold\u003c\/th\u003e\n\u003cth\u003eSizes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete Point of Use\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4, 1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation \u0026amp; Distribution\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation \u0026amp; Removal\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4, 1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemoval \u0026amp; Distribution\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eThread\u003c\/th\u003e\n\u003cth\u003eFlow\u003c\/th\u003e\n\u003cth\u003eManifold In \u0026amp; Base\u003c\/th\u003e\n\u003cth\u003eManifold Ports\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRVM-50\u003c\/td\u003e\n\u003ctd\u003eComplete point of use\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e53 CFM\u003c\/td\u003e\n\u003ctd\u003e1\/2 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRVM-75\u003c\/td\u003e\n\u003ctd\u003eComplete point of use\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003e78 CFM\u003c\/td\u003e\n\u003ctd\u003e3\/4 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRVM-100\u003c\/td\u003e\n\u003ctd\u003eComplete point of use\u003c\/td\u003e\n\u003ctd\u003e1 in\u003c\/td\u003e\n\u003ctd\u003e131 CFM\u003c\/td\u003e\n\u003ctd\u003e3\/4 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-VM-50\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; distribution\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e168 CFM\u003c\/td\u003e\n\u003ctd\u003e1\/2 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-VM-75\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; distribution\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003e236 CFM\u003c\/td\u003e\n\u003ctd\u003e3\/4 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRV-50\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; removal\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e53 CFM\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRV-75\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; removal\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003e78 CFM\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRV-100\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; removal\u003c\/td\u003e\n\u003ctd\u003e1 in\u003c\/td\u003e\n\u003ctd\u003e131 CFM\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRM-50\u003c\/td\u003e\n\u003ctd\u003eRemoval \u0026amp; distribution\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e53 CFM\u003c\/td\u003e\n\u003ctd\u003e1\/2 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRM-75\u003c\/td\u003e\n\u003ctd\u003eRemoval \u0026amp; distribution\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003e78 CFM\u003c\/td\u003e\n\u003ctd\u003e3\/4 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the isolation and distribution units flow so much more.\u003c\/strong\u003e XCDI-VM-50 is rated 168 CFM against 53 CFM for the same thread size on the other three. That is not a misprint. The VM units have no water remover element in the path, so nothing is restricting them; the 53 and 78 CFM figures are the element's rating, not the pipe's.\u003c\/p\u003e\n\u003ch2\u003eWhat Each Part Does\u003c\/h2\u003e\n\u003ch3\u003eDistribute: Ultra-Flex Manifold\u003c\/h3\u003e\n\u003cp\u003eFour separate outlet points off one block, with threaded inlet and base ports so the manifold can be fed from either end and daisy-chained. Extruded aluminum body, mounting bracket with position grooves. Supplied with three 1\/2 in NPT plugs so you open only the ports you need and the rest stay sealed.\u003c\/p\u003e\n\u003ch3\u003eRemove: Water Remover\u003c\/h3\u003e\n\u003cp\u003eThe DRI element captures water droplets mid-flow and achieves a \u003cstrong\u003e99% water removal rate\u003c\/strong\u003e. A tempered sight glass shows water being caught without opening the housing. This is the same unit sold on its own as the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-water-remover\"\u003eDRI water remover\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eIsolate: Lockable Exhausting Valve\u003c\/h3\u003e\n\u003cp\u003eAn \u003cstrong\u003eOSHA-compliant lockable isolation valve\u003c\/strong\u003e that shuts the drop and exhausts the trapped air downstream of it. Residual pressure in a hose is what fires a fitting across a shop when someone cracks a line they thought was dead, and a plain ball valve does not solve it because the air stays trapped on the tool side. This valve vents it. The same valve is sold on its own as the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-lockable-exhausting-safety-valve\"\u003elockable exhausting safety valve\u003c\/a\u003e, and mufflers are available for it.\u003c\/p\u003e\n\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Sizes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4 and 1 in NPT depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e53 to 236 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold Outlets\u003c\/td\u003e\n\u003ctd\u003eFour, 1\/2 in NPT, with threaded inlet and base ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eExtruded aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Removal Efficiency\u003c\/td\u003e\n\u003ctd\u003e99% of inline water droplets, on water remover configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOSHA-compliant lockable exhausting valve, on isolation configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied With\u003c\/td\u003e\n\u003ctd\u003eThree 1\/2 in NPT manifold plugs on manifold configurations; mounting brackets per configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification note.\u003c\/strong\u003e Champion's August 2026 price list and the DRI Products performance sheet publish thread, flow, manifold porting and list price only. Neither gives a maximum working pressure, a temperature range, dimensions or a shipping weight, so none is stated here and no catalog weight is carried on these variants. We will not borrow figures from a comparable assembly and present them as Champion's. Ask us and we will get a rating or a drawing from the factory before you order, which matters here because DRI products cannot be returned.\u003c\/p\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp\u003eWorkstation and bench drops, paint and finishing booths, maintenance bays, weld cells, assembly lines where several tools share one drop, mobile service rigs, and any drop that will be locked out for routine tool changes. The isolation and distribution units suit clean, dry air mains where water is already handled upstream and what you actually need is four outlets and a lockout point.\u003c\/p\u003e\n\u003ch2\u003eBuilding the Rest of the Drop\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-series-aluminum-compressed-air-pipe\"\u003eQuick-Lock aluminum compressed air pipe, 14mm to 63mm\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-saddle-clamp-outlet\"\u003eSaddle clamp outlets\u003c\/a\u003e to take the drop off a live main without cutting it\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-npt-adapter-plug-and-gauge\"\u003eNPT adapters, bushings, plugs and gauges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-quick-coupler\"\u003eQuick couplers and plugs\u003c\/a\u003e for the manifold outlets\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/collections\/condensate-drains\"\u003eCondensate drains\u003c\/a\u003e for the water the remover collects\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-dryers\"\u003eAir dryers\u003c\/a\u003e, which is where the water problem is actually solved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLegacy Part Numbers\u003c\/h2\u003e\n\u003cp\u003eChampion's 2015 DRI literature numbered these units differently and customers still quote from it. Same products, new numbers.\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLegacy Number\u003c\/th\u003e\n\u003cth\u003eCurrent Number\u003c\/th\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDRI-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRVM-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eComplete point of use solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIVM-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-VM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eIsolation and distribution unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIVWR-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRV-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eIsolation and removal unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCWRM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eRemoval and distribution unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSIL-03 \/ CSIL-04\u003c\/td\u003e\n\u003ctd\u003eXCQL-MF-08M \/ XCQL-MF-12M\u003c\/td\u003e\n\u003ctd\u003eMufflers for the exhausting valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAlso Available by Quote\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eXCDI-VM-100\u003c\/strong\u003e (legacy CIVM-100), the 1 in isolation and distribution unit rated 383 CFM. It appears in Champion's DRI performance sheet but carries no list price in the August 2026 price book, so it is not sold from this page. We can quote it from the factory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC1-AST\u003c\/strong\u003e, the DRI Condensate Catcher Kit, same situation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll DRI products and accessories are NO CANCEL \/ NO RETURN\u003c\/strong\u003e, stated in bold on Champion's own price list page. Confirm configuration and thread before ordering; we are glad to check it with you.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManifold plugs:\u003c\/strong\u003e manifold configurations ship with three 1\/2 in NPT plugs so unused outlets stay sealed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e complete point-of-use units include mounting brackets; isolation and distribution units include a bracket on the manifold; isolation and removal and removal and distribution units include a single bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weights:\u003c\/strong\u003e Champion publishes no weight for the DRI range, so no catalog weight is carried on these variants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\n\u003cp\u003eWe are an authorized Champion Pneumatic distributor and we sell compressed air as a system. Tell us what the drop feeds, how far it is from the dryer and whether it gets locked out, and we will tell you which of these four configurations you actually need rather than selling you the biggest one. On a no-return line that is worth five minutes.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the difference between the complete unit and the isolation and removal unit?\u003c\/h3\u003e\n\u003cp\u003eThe manifold. Both have the water remover and the lockable valve; the complete unit adds the four-port Ultra-Flex manifold and the three plugs. If the drop feeds one tool through one coupler, the isolation and removal unit is enough and saves about $60 at list.\u003c\/p\u003e\n\u003ch3\u003eWhy would I buy the isolation and distribution unit with no water remover?\u003c\/h3\u003e\n\u003cp\u003eBecause the water is already handled upstream and what you need at the wall is four outlets and a lockout. It also flows far more air for the same thread, 168 CFM on the 1\/2 in against 53 CFM, because nothing is restricting it.\u003c\/p\u003e\n\u003ch3\u003eIs the lockable valve really an OSHA lockout device?\u003c\/h3\u003e\n\u003cp\u003eChampion publishes it as an OSHA-compliant lockable isolation valve, and it accepts a padlock in the closed position. Whether a given device satisfies your site's energy control procedure is a call for your safety program, not for us; what we can tell you is that it isolates and exhausts rather than just isolating.\u003c\/p\u003e\n\u003ch3\u003eDo I need the muffler?\u003c\/h3\u003e\n\u003cp\u003eOnly for noise. The valve exhausts the trapped downstream air to atmosphere when it closes, and in a quiet bay that is a sharp crack. The mufflers are XCQL-MF-08M for 1\/2 in and XCQL-MF-12M for 3\/4 in and 1 in, listed with our \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-npt-adapter-plug-and-gauge\"\u003eQuick-Lock NPT adapters and accessories\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eCan I add a water remover to a VM unit later?\u003c\/h3\u003e\n\u003cp\u003eYou can plumb one in ahead of it, yes. Our \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-water-remover\"\u003estandalone DRI water remover\u003c\/a\u003e in the matching thread size does exactly that. It will not bolt into the VM assembly as a module, so you are building the drop rather than converting the unit.\u003c\/p\u003e\n\u003ch3\u003eCan I return it if I pick the wrong configuration?\u003c\/h3\u003e\n\u003cp\u003eNo. Champion marks the entire DRI range NO CANCEL \/ NO RETURN. Call or email us first and we will confirm it with you.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"Complete Point of Use – Remover + Valve + Manifold \/ 1\/2 in NPT","offer_id":67614872305939,"sku":"XCDI-WRVM-50","price":439.02,"currency_code":"USD","in_stock":true},{"title":"Complete Point of Use – Remover + Valve + Manifold \/ 3\/4 in NPT","offer_id":67614872338707,"sku":"XCDI-WRVM-75","price":528.93,"currency_code":"USD","in_stock":true},{"title":"Complete Point of Use – Remover + Valve + Manifold \/ 1 in NPT","offer_id":67614872371475,"sku":"XCDI-WRVM-100","price":740.34,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Distribution – Valve + Manifold \/ 1\/2 in NPT","offer_id":67614872404243,"sku":"XCDI-VM-50","price":213.84,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Distribution – Valve + Manifold \/ 3\/4 in NPT","offer_id":67614872437011,"sku":"XCDI-VM-75","price":219.51,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Removal – Valve + Remover \/ 1\/2 in NPT","offer_id":67614872469779,"sku":"XCDI-WRV-50","price":390.42,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Removal – Valve + Remover \/ 3\/4 in NPT","offer_id":67614872502547,"sku":"XCDI-WRV-75","price":483.57,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Removal – Valve + Remover \/ 1 in NPT","offer_id":67614872535315,"sku":"XCDI-WRV-100","price":638.28,"currency_code":"USD","in_stock":true},{"title":"Removal \u0026 Distribution – Remover + Manifold \/ 1\/2 in NPT","offer_id":67614872568083,"sku":"XCDI-WRM-50","price":358.02,"currency_code":"USD","in_stock":true},{"title":"Removal \u0026 Distribution – Remover + Manifold \/ 3\/4 in NPT","offer_id":67614872600851,"sku":"XCDI-WRM-75","price":452.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/DRI.jpg?v=1791199767","url":"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-drop-assembly","provider":"Warthog Air Compressor Store","version":"1.0","type":"link"}