{"product_id":"champion-cfl-series-pressure-vessel-air-filter","title":"Champion CFL Series Pressure Vessel Compressed Air Filter – Grades A–G, 3\" NPTM (625–1,250 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series pressure vessel filters\u003c\/strong\u003e are the large-capacity end of the CFL family, covering \u003cstrong\u003e625, 1,000 and 1,250 SCFM\u003c\/strong\u003e on \u003cstrong\u003e3\" NPTM\u003c\/strong\u003e connections. Where the modular CFL housings from 20 to 780 SCFM use a bayonet head and bowl, these are welded pressure vessels built to major pressure vessel directives in the Americas, Europe and Asia, with a large-diameter element chamber that keeps pressure drop low at plant-air flow rates.\u003c\/p\u003e\u003cp\u003eEvery one of the seven Champion filter grades is available in all three vessel sizes, so a single housing platform can be configured as a mechanical water separator, a general purpose particulate filter, a desiccant afterfilter, a high efficiency coalescer or an activated carbon oil vapor filter.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and filter grade from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhy a Pressure Vessel Housing Instead of a Modular Housing\u003c\/h2\u003e\u003cp\u003eAbove roughly 600 SCFM the physics change. A modular housing sized for 780 SCFM is already running a high face velocity through the element, and pushing more air through it costs real energy in differential pressure. The CFL pressure vessels put a much larger element in a much larger chamber, which drops the face velocity, holds the clean-condition pressure drop down, and stretches the interval between element changes. Because roughly one percent of compressor horsepower is consumed for every PSID of pressure drop in the system, that lower differential pressure pays for itself on a plant-air system running continuously.\u003c\/p\u003e\u003cp\u003eThe vessels also take a 3\" NPTM male pipe connection rather than the female modular ports, which is the natural tie-in size for headers feeding \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-dryers\"\u003elarge refrigerated and desiccant dryers\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003cp\u003eAll models are supplied with a differential pressure gauge and use 3\" NPTM connections. The 1,000 and 1,250 SCFM vessels ship with drain plugs as standard; externally mounted automatic drains are available.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eDimensions H x W\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003cth\u003eReplacement Element\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000A27YTW\u003c\/td\u003e\n\u003ctd\u003eA Mechanical Separator\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250A27YTW\u003c\/td\u003e\n\u003ctd\u003eA Mechanical Separator\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPAE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625B27GYTW\u003c\/td\u003e\n\u003ctd\u003eB Separator\/Filter\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000B27GYTW\u003c\/td\u003e\n\u003ctd\u003eB Separator\/Filter\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250B27GYTW\u003c\/td\u003e\n\u003ctd\u003eB Separator\/Filter\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625C27AGYTW\u003c\/td\u003e\n\u003ctd\u003eC Air Line Filter\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000C27GYTW\u003c\/td\u003e\n\u003ctd\u003eC Air Line Filter\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250C27GYTW\u003c\/td\u003e\n\u003ctd\u003eC Air Line Filter\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625D27GYTW\u003c\/td\u003e\n\u003ctd\u003eD Dry Particulate\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000D27GYTW\u003c\/td\u003e\n\u003ctd\u003eD Dry Particulate\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250D27GYTW\u003c\/td\u003e\n\u003ctd\u003eD Dry Particulate\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625E27AYTW\u003c\/td\u003e\n\u003ctd\u003eE High Efficiency\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000E27GYTW\u003c\/td\u003e\n\u003ctd\u003eE High Efficiency\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000EE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250E27GYTW\u003c\/td\u003e\n\u003ctd\u003eE High Efficiency\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625F27AYTW\u003c\/td\u003e\n\u003ctd\u003eF Max Efficiency\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000F27GYTW\u003c\/td\u003e\n\u003ctd\u003eF Max Efficiency\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250F27GYTW\u003c\/td\u003e\n\u003ctd\u003eF Max Efficiency\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625G27YTW\u003c\/td\u003e\n\u003ctd\u003eG Oil Vapor Carbon\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000G27YTW\u003c\/td\u003e\n\u003ctd\u003eG Oil Vapor Carbon\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250G27YTW\u003c\/td\u003e\n\u003ctd\u003eG Oil Vapor Carbon\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe 625 SCFM Grade A mechanical separator vessel is not listed above. The August 2026 Champion price list prints it at the same figure as the smaller modular CFL625A25 housing, which does not agree with the pricing of the other six grades on the same vessel, so it has been held back pending factory confirmation. Call us and we will quote it from the factory.\u003c\/p\u003e\u003ch2\u003eFilter Grade Selection Guide\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003ePerformance\u003c\/th\u003e\n\u003cth\u003eTypical Position\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eMechanical water separator\u003c\/td\u003e\n\u003ctd\u003eCentrifugal bulk liquid removal, no element to replace on the separator principle\u003c\/td\u003e\n\u003ctd\u003eDirectly at the compressor or aftercooler discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose separator\/filter\u003c\/td\u003e\n\u003ctd\u003e3 micron, 5 ppm remaining oil\u003c\/td\u003e\n\u003ctd\u003eFirst stage bulk protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eAir line particulate filter\u003c\/td\u003e\n\u003ctd\u003e1 micron, 1 ppm remaining oil\u003c\/td\u003e\n\u003ctd\u003ePrefilter ahead of a dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003eDry particulate afterfilter\u003c\/td\u003e\n\u003ctd\u003e1 micron, outside-to-inside flow\u003c\/td\u003e\n\u003ctd\u003eAfterfilter on a heatless desiccant dryer to catch desiccant fines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eHigh efficiency oil removal coalescer\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.008 ppm remaining oil\u003c\/td\u003e\n\u003ctd\u003eAfter the dryer for instrument quality air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eMaximum efficiency oil removal coalescer\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.0008 ppm remaining oil\u003c\/td\u003e\n\u003ctd\u003eCritical process, food and pharmaceutical duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eActivated carbon oil vapor and odor removal\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.003 ppm remaining oil vapor\u003c\/td\u003e\n\u003ctd\u003eFinal polish downstream of a Grade E or F coalescer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e625, 1,000 and 1,250 SCFM\u003c\/strong\u003e: three vessel sizes covering large plant air headers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll Seven Champion Filter Grades\u003c\/strong\u003e: one housing platform, separator through activated carbon.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\" NPTM Connections\u003c\/strong\u003e: male pipe thread sized for main header tie-ins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e: full rating on all three 3-inch NPTM vessels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e: handles hot air off an aftercooler.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Gauge Standard\u003c\/strong\u003e: dual gauge face reads in either flow direction and tells you exactly when to change the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Element Chamber\u003c\/strong\u003e: low face velocity, low clean pressure drop, long element life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Element Cores\u003c\/strong\u003e: corrosion resistant, silicone free, rated to 150°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Vessel Directive Compliant\u003c\/strong\u003e: housings conform to most major pressure vessel directives worldwide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChampion Pneumatic Quality\u003c\/strong\u003e: backed by over a century of compressed air engineering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eWelded pressure vessel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e625 – 1,250 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet \/ Outlet Connection\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM (male)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG (21 kgf\/cm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grades Available\u003c\/td\u003e\n\u003ctd\u003eA, B, C, D, E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Pressure Indication\u003c\/td\u003e\n\u003ctd\u003eGauge, dual face, remote mounting available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain, 625 SCFM\u003c\/td\u003e\n\u003ctd\u003eInternal automatic drain available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain, 1,000 and 1,250 SCFM\u003c\/td\u003e\n\u003ctd\u003eDrain plugs standard, external automatic drains available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, 625 SCFM\u003c\/td\u003e\n\u003ctd\u003e40.88\" H x 10.25\" W (1,038 x 260 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, 1,000 and 1,250 SCFM\u003c\/td\u003e\n\u003ctd\u003e48.00\" H x 16.00\" W (1,219 x 406 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e37 lb (625), 93 lb (1,000 and 1,250)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement Core\u003c\/td\u003e\n\u003ctd\u003eCorrosion resistant stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF.O.B. Shipping Point\u003c\/td\u003e\n\u003ctd\u003eOcala, FL 34474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eThese vessels belong on plant air systems in the 150 to 300 HP range and on any header carrying 600 SCFM or more: automotive assembly and paint shops, food and beverage plants, pharmaceutical and cleanroom utilities, plastics and injection molding, foundries, textile mills, glass plants, pulp and paper, and central compressor rooms feeding an entire facility. They are also the correct filtration to pair with the large end of the Champion dryer range, including \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xcnca-series-non-cycling-refrigerated-air-dryer\"\u003eXCNCA non-cycling refrigerated dryers\u003c\/a\u003e, \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xccya-series-cycling-refrigerated-air-dryer\"\u003eXCCYA cycling refrigerated dryers\u003c\/a\u003e, \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cdt-series-heatless-desiccant-air-dryer\"\u003eCDT heatless desiccant dryers\u003c\/a\u003e and \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xchl-series-heatless-desiccant-air-dryer\"\u003eXCHL heatless desiccant dryers\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eBuild Your Filtration Train\u003c\/h2\u003e\u003cp\u003eA properly staged treatment train on a large system looks like this: a \u003cstrong\u003eGrade A mechanical separator\u003c\/strong\u003e or \u003cstrong\u003eGrade C particulate filter\u003c\/strong\u003e at the aftercooler discharge to knock out bulk water and pipe scale, then the \u003cstrong\u003edryer\u003c\/strong\u003e, then a \u003cstrong\u003eGrade E or Grade F coalescing filter\u003c\/strong\u003e to bring oil carryover down to instrument levels, and finally a \u003cstrong\u003eGrade G activated carbon filter\u003c\/strong\u003e where odor or oil vapor matters. On a heatless desiccant dryer, add a \u003cstrong\u003eGrade D afterfilter\u003c\/strong\u003e to capture desiccant fines. Never install a coalescing filter upstream of bulk water removal, because flooding a coalescer shortens its life dramatically.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually, or sooner if the differential pressure gauge shows a rise of 5 PSID above the clean reading. A clogged element wastes compressed air energy and eventually risks element collapse. The 625 and 1,250 SCFM vessels share a common element, the \u003cstrong\u003eCP\u003c\/strong\u003e series, while the 1,000 SCFM vessel uses the \u003cstrong\u003eC1000\u003c\/strong\u003e series. Both are stocked as \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-pressure-vessel-replacement-filter-element\"\u003egenuine Champion replacement elements\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series filter ships with the full factory warranty, lifetime application support, and access to our compressed air engineers for sizing and system design. If you are not sure whether your header calls for the 1,000 or the 1,250 SCFM vessel, send us your actual flow and pressure and we will size it for you.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow do these differ from the modular CFL housings?\u003c\/h3\u003e\u003cp\u003eThe modular housings, 20 through 780 SCFM, use a quarter-turn bayonet head and bowl with female NPTF ports. These are welded pressure vessels with 3\" NPTM male connections, a much larger element chamber, and a full 300 PSIG rating regardless of drain configuration.\u003c\/p\u003e\u003ch3\u003eCan I get an ASME U stamped vessel?\u003c\/h3\u003e\u003cp\u003eYes. The CFL configurator offers a U stamped vessel option in place of the standard non-coded construction. The models listed here are the standard non-coded build. Call us for an ASME coded quotation.\u003c\/p\u003e\u003ch3\u003eWhich element fits my vessel?\u003c\/h3\u003e\u003cp\u003eThe 625 and 1,250 SCFM vessels take the CP element for your grade, for example CPCE for Grade C. The 1,000 SCFM vessel takes the C1000 element, for example C1000CE. Both are listed on our pressure vessel element page.\u003c\/p\u003e\u003ch3\u003eDo I size by pipe size or by flow?\u003c\/h3\u003e\u003cp\u003eAlways by flow and operating pressure, never by pipe size. Champion publishes sizing correction factors for pressures other than 100 PSIG. If you are running at 125 PSIG your vessel will pass more air than the nameplate rating; at 80 PSIG it will pass less.\u003c\/p\u003e\u003ch3\u003eHow often does the drain need attention?\u003c\/h3\u003e\u003cp\u003eThe 625 SCFM vessel can be supplied with an internal automatic drain. The 1,000 and 1,250 SCFM vessels ship with drain plugs, so most installations add an external automatic or demand drain. We stock Champion CDV1 demand drains and timed electric drains.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"1000 SCFM (3\" NPTM) \/ Grade A: Mechanical Separator","offer_id":54788518478099,"sku":"CFL1000A27YTW","price":2673.0,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade A: Mechanical Separator","offer_id":54788518510867,"sku":"CFL1250A27YTW","price":2770.2,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade B: Separator\/Filter 3 Micron","offer_id":54788518543635,"sku":"CFL625B27GYTW","price":3264.3,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade B: Separator\/Filter 3 Micron","offer_id":54788518576403,"sku":"CFL1000B27GYTW","price":3142.8,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade B: Separator\/Filter 3 Micron","offer_id":54788518609171,"sku":"CFL1250B27GYTW","price":3272.4,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade C: Air Line Filter 1 Micron","offer_id":54788518641939,"sku":"CFL625C27AGYTW","price":2948.4,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade C: Air Line Filter 1 Micron","offer_id":54788518674707,"sku":"CFL1000C27GYTW","price":2664.9,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade C: Air Line Filter 1 Micron","offer_id":54788518707475,"sku":"CFL1250C27GYTW","price":2754.0,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade D: Dry Particulate Afterfilter","offer_id":54788518740243,"sku":"CFL625D27GYTW","price":2972.7,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade D: Dry Particulate Afterfilter","offer_id":54788518773011,"sku":"CFL1000D27GYTW","price":2754.0,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade D: Dry Particulate Afterfilter","offer_id":54788518805779,"sku":"CFL1250D27GYTW","price":2835.0,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade E: High Efficiency Oil Removal","offer_id":54788518838547,"sku":"CFL625E27AYTW","price":3159.0,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade E: High Efficiency Oil Removal","offer_id":54788518871315,"sku":"CFL1000E27GYTW","price":3013.2,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade E: High Efficiency Oil Removal","offer_id":54788518904083,"sku":"CFL1250E27GYTW","price":3094.2,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade F: Maximum Efficiency Oil Removal","offer_id":54788518936851,"sku":"CFL625F27AYTW","price":3191.4,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade F: Maximum Efficiency Oil Removal","offer_id":54788518969619,"sku":"CFL1000F27GYTW","price":3110.4,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade F: Maximum Efficiency Oil Removal","offer_id":54788519002387,"sku":"CFL1250F27GYTW","price":3159.0,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade G: Oil Vapor Removal Carbon","offer_id":54788519035155,"sku":"CFL625G27YTW","price":2600.1,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade G: Oil Vapor Removal Carbon","offer_id":54788519067923,"sku":"CFL1000G27YTW","price":3061.8,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade G: Oil Vapor Removal Carbon","offer_id":54788519100691,"sku":"CFL1250G27YTW","price":3110.4,"currency_code":"USD","in_stock":true}],"url":"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-pressure-vessel-air-filter","provider":"Warthog Air Compressor Store","version":"1.0","type":"link"}