{"title":"Filtration","description":"\u003ch2\u003eCompressed Air Filtration\u003c\/h2\u003e\n\u003cp\u003eEffective filtration removes particulates, oil aerosols, and other contaminants from compressed air, protecting your tools, equipment, and finished products. The right combination of filters keeps your air clean and your system running efficiently.\u003c\/p\u003e\n\u003cp\u003eBuild your filtration train from our \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filters\"\u003eair filters\u003c\/a\u003e, \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/coalescing-air-filters\"\u003ecoalescing air filters\u003c\/a\u003e, and \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/particulate-removal-filters\"\u003eparticulate removal filters\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"ghtn-high-temperature-dust-filter-by-nano","title":"GHTN High-Temperature Dust Filter By Nano","description":"\u003cp\u003eThe nano GHTN high-temperature particulate filters, formerly sold as the NHT range, are engineered to protect compressed air systems operating at elevated temperatures up to 450 F. Custom-engineered filter media handles the heat while delivering high-efficiency 1 micron dry particulate removal with minimal pressure drop, and the machined and die-cast aluminum housing stands up to demanding industrial duty. The range spans eleven models from 15 to 1600 SCFM with 1\/4\" to 3\" NPT connections, making the GHTN the ideal particulate guard downstream of externally heated or blower purge desiccant air dryers, where discharge temperatures are too high for standard aluminum filters.\u003c\/p\u003e\n\u003ch3\u003eHow to select your GHTN filter\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMatch the model to your flow and pipe size. Choose the GHTN rated at or above your actual SCFM at 100 psig, from GHTN 0015 (15 SCFM, 1\/4\" NPT) up to GHTN 1600 (1600 SCFM, 3\" NPT).\u003c\/li\u003e\n\u003cli\u003eConfirm your inlet temperature. The GHTN is built for high-inlet-temperature air with a design operating temperature range of 35 to 450 F.\u003c\/li\u003e\n\u003cli\u003eConfirm your operating pressure. The design operating pressure range is 0 to 150 psig.\u003c\/li\u003e\n\u003cli\u003ePlan element service. Each filter uses a 1 micron GEHT M1 dry particulate element with a maximum life of 12 months or 4000 hours, and a recommended change-out at 5.0 psid.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHandles high inlet air temperatures up to 450 F.\u003c\/li\u003e\n\u003cli\u003e1 micron dry particulate removal from a custom-engineered high-temperature media.\u003c\/li\u003e\n\u003cli\u003ePush-fit element design with dual O-ring seals for optimum sealing and mechanical strength.\u003c\/li\u003e\n\u003cli\u003eMachined and die-cast aluminum housing for durability in demanding environments.\u003c\/li\u003e\n\u003cli\u003eManual ball-valve condensate drain included.\u003c\/li\u003e\n\u003cli\u003eLow clean pressure drop of 1.2 psid keeps energy costs down.\u003c\/li\u003e\n\u003cli\u003eIdeal downstream of externally heated and blower purge desiccant dryers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated flow: 15 to 1600 SCFM at 100 psig.\u003c\/li\u003e\n\u003cli\u003eConnections: 1\/4\", 3\/8\", 1\/2\", 3\/4\", 1\", 1-1\/2\", 2\" and 3\" NPT depending on model.\u003c\/li\u003e\n\u003cli\u003eDesign operating pressure range: 0 to 150 psig.\u003c\/li\u003e\n\u003cli\u003eDesign operating temperature range: 35 to 450 F.\u003c\/li\u003e\n\u003cli\u003eFiltration grade: M1, 1 micron dry particulate.\u003c\/li\u003e\n\u003cli\u003eReplacement element: GEHT M1 series (outside-to-inside flow).\u003c\/li\u003e\n\u003cli\u003ePressure drop: 1.2 psid clean, 5.0 psid recommended replacement.\u003c\/li\u003e\n\u003cli\u003eMaximum element life: 12 months or 4000 hours.\u003c\/li\u003e\n\u003cli\u003eHousing material: machined and die-cast aluminum. Manual ball-valve drain included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIdeal applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eParticulate protection downstream of externally heated desiccant dryers.\u003c\/li\u003e\n\u003cli\u003eParticulate protection downstream of blower purge desiccant dryers.\u003c\/li\u003e\n\u003cli\u003eHigh-temperature process and instrument air.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial compressed air where discharge temperatures exceed standard filter ratings.\u003c\/li\u003e\n\u003cli\u003eApplications requiring durable, low pressure drop dust removal in hot air streams.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the GHTN the same as the older NHT filter?\u003c\/strong\u003e Yes. The nano NHT high-temperature particulate filter range has been superseded by the GHTN range. The GHTN is the current model with the same size lineup and the GEHT replacement elements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat temperature can the GHTN handle?\u003c\/strong\u003e The GHTN has a design operating temperature range of 35 to 450 F, which is why it is used on hot air downstream of heated desiccant dryers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the filtration grade?\u003c\/strong\u003e Every GHTN uses a 1 micron M1 dry particulate element. It is a particulate filter, not a coalescing or oil vapor filter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich model do I need?\u003c\/strong\u003e Select the model whose SCFM rating at 100 psig meets or exceeds your actual flow, and confirm the NPT connection matches your piping, from 15 SCFM (1\/4\" NPT) to 1600 SCFM (3\" NPT).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the element be replaced?\u003c\/strong\u003e The GEHT element has a maximum life of 12 months or 4000 hours, with recommended replacement once pressure drop reaches 5.0 psid.\u003c\/p\u003e\n\u003cp\u003eSpecifications are drawn from the nano GHTN datasheet and are for general reference only. Confirm final selection against the current nano product brochure and user guide.\u003c\/p\u003e","brand":"Nano","offers":[{"title":"300 CFM \/ 1.5\"","offer_id":51811923689747,"sku":"8102374705","price":2117.0,"currency_code":"USD","in_stock":true},{"title":"450 CFM \/ 2\"","offer_id":51811923722515,"sku":"8102374706","price":2250.0,"currency_code":"USD","in_stock":true},{"title":"650 CFM \/ 2\"","offer_id":51811923755283,"sku":"8102374707","price":2632.0,"currency_code":"USD","in_stock":true},{"title":"1000 CFM \/ 3\"","offer_id":51811923788051,"sku":"8102374708","price":3069.0,"currency_code":"USD","in_stock":true},{"title":"1250 CFM \/ 3\"","offer_id":51811923820819,"sku":"8102374709","price":3292.0,"currency_code":"USD","in_stock":true},{"title":"1600 CFM \/ 3\"","offer_id":51811923853587,"sku":"8102374710","price":3573.0,"currency_code":"USD","in_stock":true},{"title":"150 CFM \/ 1\"","offer_id":51811923886355,"sku":"8102374704","price":1378.0,"currency_code":"USD","in_stock":true},{"title":"75 CFM \/ .75\"","offer_id":51811923919123,"sku":"8102374703","price":1131.0,"currency_code":"USD","in_stock":true},{"title":"65 CFM \/ .5\"","offer_id":51811923951891,"sku":"8102374702","price":908.0,"currency_code":"USD","in_stock":true},{"title":"30 CFM \/ .375","offer_id":51811923984659,"sku":"8102374701","price":694.0,"currency_code":"USD","in_stock":true},{"title":"15 CFM \/ .25\"","offer_id":51811924017427,"sku":"8102374700","price":577.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/F3-High-Temperature-Dust-Filter-Nano_d5b2b944-f824-45c2-9f1c-3f2de5179be5.jpg?v=1772136078"},{"product_id":"forged-brass-y-strainers-by-kingston","title":"Forged Brass Y-Strainers by Kingston","description":"\u003cp\u003eThe Kingston forged brass Y-strainer protects pumps, valves, meters, and downstream equipment by trapping rust, scale, sediment, and debris before it can cause damage. Built from a single heavy-duty forged brass body with a 20-mesh stainless steel screen, it delivers reliable inline filtration for water, air, oil, and gas service in a compact, easy-to-maintain package.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy-duty forged brass body\u003c\/li\u003e\n\u003cli\u003e20-mesh 304 stainless steel wire screen\u003c\/li\u003e\n\u003cli\u003eTapped cap with removable plug for fast blowdown and screen cleaning\u003c\/li\u003e\n\u003cli\u003eFNPT female threaded inlet and outlet\u003c\/li\u003e\n\u003cli\u003eRated up to 200 PSI WOG (water, oil, gas)\u003c\/li\u003e\n\u003cli\u003eAvailable sizes: 1\/2\", 3\/4\", 1\", 1-1\/4\", 1-1\/2\", and 2\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cp\u003eIdeal for compressed air lines, water supply and irrigation, pump and meter protection, steam and condensate systems, hydronic heating, and general industrial process piping. The angled Y body installs in horizontal or vertical (downward-flow) runs, and the tapped clean-out plug lets you flush the screen without removing the strainer from the line.\u003c\/p\u003e\n\u003cp\u003eEngineered for dependable, low-maintenance service, the Kingston forged brass Y-strainer combines a durable brass body, 20-mesh stainless screen, and 200 PSI WOG rating to keep your system clean and running across 1\/2\" through 2\" FNPT connections.\u003c\/p\u003e","brand":"Warthog Air Compressor Store","offers":[{"title":"1 1\/2\" NPT","offer_id":51817028550931,"sku":"BYS150","price":60.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/4\" NPT","offer_id":51817028583699,"sku":"BYS125","price":50.0,"currency_code":"USD","in_stock":true},{"title":"1\" NPT","offer_id":51817028616467,"sku":"BYS100","price":33.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" NPT","offer_id":51817028649235,"sku":"BYS075","price":22.0,"currency_code":"USD","in_stock":true},{"title":"2\" NPT","offer_id":51817028682003,"sku":"BYS200","price":107.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" NPT","offer_id":51817028714771,"sku":"BYS050","price":17.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/Forged-Brass-Y-Strainer.jpg?v=1772197638"},{"product_id":"nvr-oil-vapor-removal-system-by-nano","title":"NVR Oil Vapor Removal System By Nano","description":"\u003cp\u003e\u003cstrong\u003eThe nano NVR oil vapor removal system\u003c\/strong\u003e uses activated carbon adsorption to strip oil vapor and odor from compressed air, delivering technically oil-free air with a maximum outlet oil content of \u003cstrong\u003e0.003 ppm\u003c\/strong\u003e. Rated 40 to 1500 SCFM, its compact extruded-aluminum design is far smaller than traditional carbon towers and runs at low pressure drop for economical point-of-use or compressor-room installation.\u003c\/p\u003e\n\u003ch3\u003eHow the NVR works\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCompressed air enters a cartridge packed with activated carbon and fitted with an integral diffuser.\u003c\/li\u003e\n\u003cli\u003eThe carbon adsorbs oil vapor and associated odors as the air passes through.\u003c\/li\u003e\n\u003cli\u003eA built-in 1-micron dust filter cleans the air on the way out, so no separate downstream filter is needed.\u003c\/li\u003e\n\u003cli\u003eClean, technically oil-free air leaves the modular aluminum housing at low pressure drop.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 8573.1 Class 1 for oil\u003c\/strong\u003e, outlet oil content as low as 0.003 ppm at 95°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActivated carbon cartridge\u003c\/strong\u003e with integral diffuser and built-in 1-micron dust filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtruded-aluminum, modular design\u003c\/strong\u003e that is compact and lightweight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow pressure drop\u003c\/strong\u003e for efficient, economical operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoughly 12-month cartridge life\u003c\/strong\u003e under recommended conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow rate:\u003c\/strong\u003e 40 – 1500 SCFM at 100 psig\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e ½\" to 2½\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir quality:\u003c\/strong\u003e ISO 8573.1:2010 Class 1 (oil)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum outlet oil content:\u003c\/strong\u003e 0.003 ppm at 95°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum working pressure:\u003c\/strong\u003e 232 psig\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 36 – 95°F (122°F max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCartridge life:\u003c\/strong\u003e approximately 12 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRequired inlet air quality\u003c\/h3\u003e\n\u003cp\u003eThe NVR is a finishing (polishing) stage and needs suitably pre-treated air upstream. Provide air that is already dried and filtered to at least: maximum particulate 0.01 micron, maximum pressure dew point −40°F, and maximum oil content 0.05 ppm. Pair it with a desiccant dryer and coalescing filtration for best results and cartridge life.\u003c\/p\u003e\n\u003ch3\u003eIdeal applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFood, beverage, and packaging\u003c\/li\u003e\n\u003cli\u003ePharmaceutical and laboratory air\u003c\/li\u003e\n\u003cli\u003eElectronics and critical manufacturing\u003c\/li\u003e\n\u003cli\u003eAny process needing oil-free air without the cost of an oil-free compressor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow clean is the outlet air?\u003c\/strong\u003e\u003cbr\u003eDown to 0.003 ppm oil at 95°F, meeting ISO 8573.1 Class 1 for oil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a separate downstream filter?\u003c\/strong\u003e\u003cbr\u003eNo. A 1-micron dust filter is built into the cartridge, eliminating the need for external downstream filtration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need anything upstream?\u003c\/strong\u003e\u003cbr\u003eYes. Supply dried, filtered air (particulate to 0.01 micron, dew point to −40°F, oil to 0.05 ppm). It polishes pre-treated air rather than replacing a dryer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often are cartridges replaced?\u003c\/strong\u003e\u003cbr\u003eAbout every 12 months under recommended operating conditions.\u003c\/p\u003e","brand":"Nano","offers":[{"title":"40 SCFM \/ .5\" NPT","offer_id":54504174354707,"sku":"8102077144","price":2429.0,"currency_code":"USD","in_stock":true},{"title":"185 SCFM \/ 1\" NPT","offer_id":54504174387475,"sku":"8102076901","price":3119.0,"currency_code":"USD","in_stock":true},{"title":"370 SCFM \/ 1\" NPT","offer_id":54504174420243,"sku":"8102076904","price":3690.0,"currency_code":"USD","in_stock":true},{"title":"750 SCFM \/ 2.5\" NPT","offer_id":54504174453011,"sku":"8095090338","price":6974.0,"currency_code":"USD","in_stock":true},{"title":"1100 SCFM \/ 2.5\" NPT","offer_id":54504174485779,"sku":"8095090339","price":6934.0,"currency_code":"USD","in_stock":true},{"title":"1500 SCFM \/ 2.5\" NPT","offer_id":54504174518547,"sku":"NVR1500","price":7935.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/nvr_square_1200.png?v=1785259042"},{"product_id":"akc-activated-carbon-adsorber-tower-oil-vapor-removal-by-nano","title":"AKC Activated Carbon Adsorber Tower for Oil Vapor Removal By Nano","description":"\u003cp\u003eThe \u003cstrong\u003enano AKC Activated Carbon Adsorber Tower\u003c\/strong\u003e is the definitive solution for eliminating oil vapor, hydrocarbons, and odors from compressed air. Each tower holds a large bed of loose activated carbon that captures oil molecules as air passes through, delivering clean, oil-free air with a maximum outlet oil content of just 0.003 ppm. Available in 25 flow ratings from 30 to 5000 SCFM, the AKC series protects downstream equipment and critical processes in food and beverage, pharmaceutical, and microprocessor manufacturing. A built-in residual oil indicator shows the remaining life of the carbon, so you always know when a recharge is due.\u003c\/p\u003e\n\n\u003ch3\u003eHow to select your AKC tower\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatch the flow rating.\u003c\/strong\u003e Choose the model whose SCFM rating meets or exceeds your system flow at 100 psig and 100°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply correction factors if needed.\u003c\/strong\u003e Ratings are stated at 100 psig and 100°F. Lower inlet pressure or higher inlet temperature reduces capacity, so contact nano to confirm sizing for other conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify inlet air quality.\u003c\/strong\u003e The AKC requires upstream filtration to 0.01 micron, a pressure dew point of -40°F or better, and inlet oil content at or below 0.05 ppm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the connection.\u003c\/strong\u003e Models use 1\/2\" to 2\" NPT threaded connections up to 600 SCFM, and 3\", 4\", or 6\" flanged connections on the larger towers.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves oil vapor, hydrocarbons, and odors to a 0.003 ppm outlet oil content\u003c\/li\u003e\n\u003cli\u003eLarge bed of loose activated carbon for maximum adsorption capacity and long service life\u003c\/li\u003e\n\u003cli\u003eBuilt-in residual oil indicator to gauge remaining activated carbon life\u003c\/li\u003e\n\u003cli\u003eBroad range: 25 models from 30 to 5000 SCFM\u003c\/li\u003e\n\u003cli\u003eSkid-mounted vessel design with integral support stand\u003c\/li\u003e\n\u003cli\u003eNPT or flanged connections to suit the flow rating\u003c\/li\u003e\n\u003cli\u003eProtects downstream dryers, instruments, and processes from oil contamination\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated flow:\u003c\/strong\u003e 30 to 5000 SCFM (at 100 psig, 100°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum working pressure:\u003c\/strong\u003e 232 psig\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended operating temperature:\u003c\/strong\u003e 36 to 95°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum operating temperature:\u003c\/strong\u003e 122°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum outlet oil content (at 95°F):\u003c\/strong\u003e 0.003 ppm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet air quality required:\u003c\/strong\u003e 0.01 micron particulate, -40°F pressure dew point, 0.05 ppm max oil content\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e 1\/2\" to 2\" NPT (30 to 600 SCFM); 3\", 4\", or 6\" flanged (750 SCFM and up)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstimated cartridge life:\u003c\/strong\u003e approximately 12 months (application dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eConnection reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\/2\" NPT:\u003c\/strong\u003e AKC-30, AKC-40, AKC-50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\/4\" NPT:\u003c\/strong\u003e AKC-60, AKC-80\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\" NPT:\u003c\/strong\u003e AKC-100, AKC-150\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-1\/2\" NPT:\u003c\/strong\u003e AKC-200, AKC-250, AKC-300, AKC-350\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\" NPT:\u003c\/strong\u003e AKC-450, AKC-500, AKC-600\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\" flanged:\u003c\/strong\u003e AKC-750, AKC-1000, AKC-1250\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\" flanged:\u003c\/strong\u003e AKC-1500, AKC-2000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6\" flanged:\u003c\/strong\u003e AKC-2500, AKC-3000, AKC-3500, AKC-4000, AKC-4500, AKC-5000\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIdeal applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFood and beverage processing and packaging\u003c\/li\u003e\n\u003cli\u003ePharmaceutical and life-science manufacturing\u003c\/li\u003e\n\u003cli\u003eMicroprocessor and electronics manufacturing\u003c\/li\u003e\n\u003cli\u003eOdor and hydrocarbon removal from compressed air\u003c\/li\u003e\n\u003cli\u003eProtection of downstream dryers, membranes, and instrumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow clean is the outlet air?\u003c\/strong\u003e The AKC delivers a maximum outlet oil content of 0.003 ppm at 95°F, effectively producing oil-vapor-free compressed air.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I still need coalescing prefilters?\u003c\/strong\u003e Yes. The AKC removes oil vapor, not bulk liquid or particulate. Upstream filtration to 0.01 micron with a -40°F dew point and inlet oil content at or below 0.05 ppm is required for rated performance and carbon life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know when to replace the activated carbon?\u003c\/strong\u003e Each tower has a built-in residual oil indicator that shows the remaining life of the carbon bed. Estimated life is roughly 12 months depending on inlet conditions and duty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if my pressure or temperature differs from the ratings?\u003c\/strong\u003e Ratings are based on 100 psig and 100°F. Lower pressure or higher temperature reduces effective capacity; apply nano's correction factors or contact nano to confirm the right model for your conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat connection will my tower have?\u003c\/strong\u003e Models from 30 to 600 SCFM use 1\/2\" to 2\" NPT threaded connections, while 750 SCFM and larger towers use 3\", 4\", or 6\" flanged connections.\u003c\/p\u003e","brand":"Nano","offers":[{"title":"30 SCFM","offer_id":54510293188883,"sku":"8102453000","price":1452.0,"currency_code":"USD","in_stock":true},{"title":"40 SCFM","offer_id":54510293221651,"sku":"8102453001","price":1924.0,"currency_code":"USD","in_stock":true},{"title":"50 SCFM","offer_id":54510293254419,"sku":"8102453002","price":2006.0,"currency_code":"USD","in_stock":true},{"title":"60 SCFM","offer_id":54510293287187,"sku":"8102453003","price":2025.0,"currency_code":"USD","in_stock":true},{"title":"80 SCFM","offer_id":54510293319955,"sku":"8102453004","price":2255.0,"currency_code":"USD","in_stock":true},{"title":"100 SCFM","offer_id":54510293352723,"sku":"8102453005","price":2820.0,"currency_code":"USD","in_stock":true},{"title":"150 SCFM","offer_id":54510293385491,"sku":"8102453006","price":3146.0,"currency_code":"USD","in_stock":true},{"title":"200 SCFM","offer_id":54510293418259,"sku":"8102453007","price":3274.0,"currency_code":"USD","in_stock":true},{"title":"250 SCFM","offer_id":54510293451027,"sku":"8102453008","price":3565.0,"currency_code":"USD","in_stock":true},{"title":"300 SCFM","offer_id":54510293483795,"sku":"8102453009","price":3749.0,"currency_code":"USD","in_stock":true},{"title":"350 SCFM","offer_id":54510293516563,"sku":"8102453010","price":3994.0,"currency_code":"USD","in_stock":true},{"title":"450 SCFM","offer_id":54510293549331,"sku":"8102453011","price":4336.0,"currency_code":"USD","in_stock":true},{"title":"500 SCFM","offer_id":54510293582099,"sku":"8102453012","price":4549.0,"currency_code":"USD","in_stock":true},{"title":"600 SCFM","offer_id":54510293614867,"sku":"8102453013","price":5114.0,"currency_code":"USD","in_stock":true},{"title":"750 SCFM","offer_id":54510293647635,"sku":"8102453014","price":6248.0,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM","offer_id":54510293680403,"sku":"8102453015","price":7195.0,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM","offer_id":54510293713171,"sku":"8102453016","price":8465.0,"currency_code":"USD","in_stock":true},{"title":"1500 SCFM","offer_id":54510293745939,"sku":"8102453017","price":9584.0,"currency_code":"USD","in_stock":true},{"title":"2000 SCFM","offer_id":54510293778707,"sku":"8102453018","price":12279.0,"currency_code":"USD","in_stock":true},{"title":"2500 SCFM","offer_id":54510293811475,"sku":"8102453019","price":16048.0,"currency_code":"USD","in_stock":true},{"title":"3000 SCFM","offer_id":54510293844243,"sku":"8102453020","price":16048.0,"currency_code":"USD","in_stock":true},{"title":"3500 SCFM","offer_id":54510293877011,"sku":"8102453021","price":17171.0,"currency_code":"USD","in_stock":true},{"title":"4000 SCFM","offer_id":54510293909779,"sku":"8102453022","price":28720.0,"currency_code":"USD","in_stock":true},{"title":"4500 SCFM","offer_id":54510293942547,"sku":"8102453023","price":36923.0,"currency_code":"USD","in_stock":true},{"title":"5000 SCFM","offer_id":54510293975315,"sku":"8102453024","price":38307.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/akc-activated-carbon-adsorber-tower-by-nano.png?v=1785344317"},{"product_id":"gmv-medical-vacuum-filter-by-nano","title":"GMV Medical Vacuum Filter By Nano","description":"\u003cp\u003eThe \u003cstrong\u003enano GMV Medical Vacuum Filter\u003c\/strong\u003e protects vacuum pumps and staff by removing solid, liquid, and bacterial contamination from medical vacuum systems before it can reach the pump or be exhausted into the surrounding environment. Built to the highest industry standards, including ISO 7396-1, HTM 02-01, and the 2018 revision of NFPA (5.1.3.7.4), the GMV range is the go-to choice for medical, dental, and veterinary vacuum applications. Each filter includes an easy-to-remove sterilizable drain flask and manual valve as standard, and the cast aluminum housing carries a 10-year warranty and is designed in accordance with ASME pressure vessel standards.\u003c\/p\u003e\n\n\u003ch3\u003eHow to select your GMV filter\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize to your vacuum flow.\u003c\/strong\u003e Choose the model whose free aspirated air rating (1 to 125 SCFM) meets or exceeds your medical vacuum system demand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatch the connection.\u003c\/strong\u003e GMV housings use 1\/4\" to 3\" NPT (F) connections that scale with the flow rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the standard required.\u003c\/strong\u003e All models exceed HTM 02-01 (\u0026gt;99.995%) with \u0026gt;99.9999% efficiency at 0.01 micron and meet ISO 7396-1 and NFPA 2018.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan for element service.\u003c\/strong\u003e Replace the filter element every 6 months or 1000 hours to maintain performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves airborne particles, bacteria, viruses, dust, oil vapors, and moisture from vacuum air\u003c\/li\u003e\n\u003cli\u003e\u0026gt;99.9999% filtration efficiency at 0.01 micron, exceeding HTM 02-01\u003c\/li\u003e\n\u003cli\u003eMeets ISO 7396-1, HTM 02-01, and NFPA 2018 (5.1.3.7.4)\u003c\/li\u003e\n\u003cli\u003eOleophobic borosilicate microfiber media with open-cell reticulated foam prefilter\u003c\/li\u003e\n\u003cli\u003eSterilizable, easy-to-remove drain flask and manual valve included as standard\u003c\/li\u003e\n\u003cli\u003e\"Dead Stop\" bowl feature for full closure without over-tightening\u003c\/li\u003e\n\u003cli\u003eCast aluminum alloy housing with internal and external E-Coat finish for corrosion protection\u003c\/li\u003e\n\u003cli\u003eASME-standard housing design with a 10-year housing warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree aspirated air flow:\u003c\/strong\u003e 1 to 125 SCFM (at 9.2 psia)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e 1\/4\" to 3\" NPT (F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltration:\u003c\/strong\u003e 0.01 micron, \u0026gt;99.9999% efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign operating pressure:\u003c\/strong\u003e full vacuum to 7 psig\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDesign operating temperature:\u003c\/strong\u003e 35 to 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElement life:\u003c\/strong\u003e 6 months or 1000 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e ISO 7396-1, HTM 02-01, NFPA 2018 (5.1.3.7.4), ASME pressure vessel design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e housing 10 years; other components 18 months from shipment or 12 months from installation, whichever is first (100% parts)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eModel reference (free aspirated air, connection)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0025:\u003c\/strong\u003e 1 SCFM, 1\/4\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0032:\u003c\/strong\u003e 2 SCFM, 3\/8\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0050:\u003c\/strong\u003e 4 SCFM, 1\/2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0070:\u003c\/strong\u003e 7 SCFM, 1\/2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0085:\u003c\/strong\u003e 8 SCFM, 3\/4\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0105:\u003c\/strong\u003e 10 SCFM, 1\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0175:\u003c\/strong\u003e 17 SCFM, 1\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0280:\u003c\/strong\u003e 34 SCFM, 1-1\/4\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0325:\u003c\/strong\u003e 37 SCFM, 1-1\/2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0450:\u003c\/strong\u003e 39 SCFM, 2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0700:\u003c\/strong\u003e 55 SCFM, 2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0850:\u003c\/strong\u003e 93 SCFM, 2-1\/2\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 0900:\u003c\/strong\u003e 106 SCFM, 3\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 1250:\u003c\/strong\u003e 118 SCFM, 3\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGMV 1500:\u003c\/strong\u003e 125 SCFM, 3\" NPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIdeal applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHospital and surgical medical vacuum systems\u003c\/li\u003e\n\u003cli\u003eOperating rooms and intensive care units\u003c\/li\u003e\n\u003cli\u003eDental vacuum and suction systems\u003c\/li\u003e\n\u003cli\u003eVeterinary hospitals and clinics\u003c\/li\u003e\n\u003cli\u003eLaboratory and analytical vacuum systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a medical vacuum filter do?\u003c\/strong\u003e It removes dust, bacteria, viruses, and particulate from the vacuum system so contaminated air is not drawn into the pump or exhausted into the facility, protecting both patients and staff.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the filtration rating?\u003c\/strong\u003e The GMV range filters to 0.01 micron with greater than 99.9999% efficiency, exceeding the HTM 02-01 requirement of greater than 99.995%.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often is the element replaced?\u003c\/strong\u003e Replace the filter element every 6 months or 1000 hours, whichever comes first.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the drain flask reusable?\u003c\/strong\u003e Yes. The drain flask is easily removable and can be sterilized for repeated use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat standards does it meet?\u003c\/strong\u003e The GMV range meets ISO 7396-1, HTM 02-01, and the 2018 revision of NFPA (5.1.3.7.4), and the housing is designed to ASME pressure vessel standards.\u003c\/p\u003e","brand":"Nano","offers":[{"title":"GMV 0025 (1 SCFM)","offer_id":54510545666323,"sku":"8095170492","price":308.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0032 (2 SCFM)","offer_id":54510545699091,"sku":"8095170493","price":333.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0050 (4 SCFM)","offer_id":54510545731859,"sku":"8095170494","price":378.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0070 (7 SCFM)","offer_id":54510545764627,"sku":"8095170495","price":401.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0085 (8 SCFM)","offer_id":54510545797395,"sku":"8095170496","price":446.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0105 (10 SCFM)","offer_id":54510545830163,"sku":"8095170497","price":550.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0175 (17 SCFM)","offer_id":54510545862931,"sku":"8095170498","price":629.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0280 (34 SCFM)","offer_id":54510545895699,"sku":"8095170499","price":789.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0325 (37 SCFM)","offer_id":54510545928467,"sku":"8095170500","price":837.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0450 (39 SCFM)","offer_id":54510545961235,"sku":"8095170501","price":1315.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0700 (55 SCFM)","offer_id":54510545994003,"sku":"8095170502","price":1487.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0850 (93 SCFM)","offer_id":54510546026771,"sku":"8095170503","price":1832.0,"currency_code":"USD","in_stock":true},{"title":"GMV 0900 (106 SCFM)","offer_id":54510546059539,"sku":"8095170504","price":2079.0,"currency_code":"USD","in_stock":true},{"title":"GMV 1250 (118 SCFM)","offer_id":54510546092307,"sku":"8095170505","price":2542.0,"currency_code":"USD","in_stock":true},{"title":"GMV 1500 (125 SCFM)","offer_id":54510546125075,"sku":"8095170506","price":3004.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/gmv-medical-vacuum-filter-by-nano.png?v=1785344706"},{"product_id":"g50n-mid-pressure-aluminum-compressed-air-filter-by-nano","title":"G50N Mid-Pressure Aluminum Compressed Air Filter By Nano","description":"\u003cp\u003eThe nano G50N mid-pressure aluminum compressed air and gas filters deliver dependable, high-efficiency filtration at working pressures up to 725 psig. Machined and die-cast aluminum housings pair with proprietary hydrophobic and oleophobic borosilicate glass microfiber media to strip water, particulate, oil aerosol and oil vapor from demanding air systems while holding pressure drop low. The range spans nine housing sizes from 95 to 1885 SCFM with 1\/4\" to 2\" NPT connections, and every housing is offered in the full grade lineup so you can build the exact air quality your process requires. Designed to ASME standards and tested to ISO 8573-1:2010, the G50N is the modern replacement for the legacy N50A mid-pressure aluminum filter range.\u003c\/p\u003e\n\u003ch3\u003eHow to select your G50N filter\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMatch the housing to your flow and pipe size. Choose the model rated at or above your actual SCFM at 725 psig, from 0095 (95 SCFM, 1\/4\" NPT) up to 1885 (1885 SCFM, 2\" NPT).\u003c\/li\u003e\n\u003cli\u003eChoose the grade for the air quality you need. Coarse liquid and dust removal uses WS, M25 or M5; fine coalescing uses M1 (1 micron) then M01 (0.01 micron); oil vapor and odor removal uses AC activated carbon.\u003c\/li\u003e\n\u003cli\u003eStage filters in series for critical air. A typical train is a water separator or M1 pre-filter, an M01 high-efficiency coalescer, then an AC carbon filter for vapor-free, technically oil-free air.\u003c\/li\u003e\n\u003cli\u003eConfirm your operating temperature. WS, M1 and M01 grades run 35 to 212 F; AC carbon grade is rated 35 to 77 F.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWorking pressure to 725 psig for mid and high-pressure compressed air and gas duty.\u003c\/li\u003e\n\u003cli\u003eProprietary hydrophobic and oleophobic borosilicate glass microfiber media repels oil and water for high efficiency with minimal pressure drop.\u003c\/li\u003e\n\u003cli\u003ePush-fit element design with dual O-ring seals for optimum sealing and mechanical strength.\u003c\/li\u003e\n\u003cli\u003eRobust elements with internal and external stainless steel support cores and glass-filled nylon end caps.\u003c\/li\u003e\n\u003cli\u003eMachined and die-cast aluminum housing built to ASME design standards in an ISO 9001 facility.\u003c\/li\u003e\n\u003cli\u003eManual ball-valve condensate drain included on WS, M1 and M01 grades (1\/4\" connection).\u003c\/li\u003e\n\u003cli\u003eSix interchangeable element grades across all nine housing sizes for tailored air quality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated flow: 95 to 1885 SCFM at 725 psig.\u003c\/li\u003e\n\u003cli\u003eConnections: 1\/4\", 3\/8\", 1\/2\", 3\/4\", 1\", 1-1\/2\" and 2\" NPT depending on model.\u003c\/li\u003e\n\u003cli\u003eDesign operating pressure range: 0 to 725 psig.\u003c\/li\u003e\n\u003cli\u003eDesign operating temperature range: 35 to 248 F (recommended 35 to 212 F; AC grade 35 to 77 F).\u003c\/li\u003e\n\u003cli\u003eGrade WS water separator: bulk liquid removal, max oil carryover 25 ppm.\u003c\/li\u003e\n\u003cli\u003eGrade M25 \/ M5: 25 micron and 5 micron particulate removal.\u003c\/li\u003e\n\u003cli\u003eGrade M1: 1 micron particulate and coalescing, max oil carryover 0.1 ppm.\u003c\/li\u003e\n\u003cli\u003eGrade M01: 0.01 micron coalescing, max oil carryover 0.01 ppm.\u003c\/li\u003e\n\u003cli\u003eGrade AC: activated carbon, oil vapor removal to 0.003 ppm at 68 F.\u003c\/li\u003e\n\u003cli\u003eHousing material: machined and die-cast aluminum. Tested to ISO 8573-1:2010.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIdeal applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePET bottle blowing and high-pressure packaging air.\u003c\/li\u003e\n\u003cli\u003eOffshore and instrumentation air where reliability is critical.\u003c\/li\u003e\n\u003cli\u003eMedical, laboratory and pharmaceutical compressed air.\u003c\/li\u003e\n\u003cli\u003eLaser cutting, metal fabrication and CNC machining.\u003c\/li\u003e\n\u003cli\u003eGeneral heavy industrial and process air requiring clean, dry, oil-free air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the M1, M01 and AC grades?\u003c\/strong\u003e M1 is a 1 micron coalescing grade for general oil and particulate removal, M01 is a finer 0.01 micron high-efficiency coalescer used downstream of an M1, and AC is an activated carbon grade that removes oil vapor and odors downstream of coalescing filters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much pressure can the G50N handle?\u003c\/strong\u003e The G50N range is rated for working pressure up to 725 psig, which is why it is called a mid-pressure aluminum filter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich housing size do I need?\u003c\/strong\u003e Select the housing whose SCFM rating at 725 psig meets or exceeds your actual flow, and confirm the NPT connection matches your piping. Sizes run from 95 SCFM (1\/4\" NPT) to 1885 SCFM (2\" NPT).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the filter include a drain?\u003c\/strong\u003e WS, M1 and M01 grades include a manual ball-valve condensate drain with a 1\/4\" connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the G50N replace the older N50A filters?\u003c\/strong\u003e Yes. The G50N mid-pressure aluminum filter range supersedes the legacy N50A range.\u003c\/p\u003e\n\u003cp\u003eSpecifications are drawn from the nano G50N datasheet and are for general reference only. Confirm final selection against the current nano product brochure and user guide.\u003c\/p\u003e","brand":"Nano","offers":[{"title":"95 SCFM (1\/4\" NPT) \/ WS (Water Separator)","offer_id":54513255547155,"sku":"8102374663","price":525.0,"currency_code":"USD","in_stock":true},{"title":"95 SCFM (1\/4\" NPT) \/ M25 (25 Micron)","offer_id":54513255579923,"sku":"G50N0095M25","price":525.0,"currency_code":"USD","in_stock":true},{"title":"95 SCFM (1\/4\" NPT) \/ M5 (5 Micron)","offer_id":54513255612691,"sku":"G50N0095M5","price":525.0,"currency_code":"USD","in_stock":true},{"title":"95 SCFM (1\/4\" NPT) \/ M1 (1 Micron)","offer_id":54513255645459,"sku":"8102374636","price":525.0,"currency_code":"USD","in_stock":true},{"title":"95 SCFM (1\/4\" NPT) \/ M01 (0.01 Micron)","offer_id":54513255678227,"sku":"8102374645","price":525.0,"currency_code":"USD","in_stock":true},{"title":"95 SCFM (1\/4\" NPT) \/ AC (Activated Carbon)","offer_id":54513255710995,"sku":"8102374654","price":525.0,"currency_code":"USD","in_stock":true},{"title":"150 SCFM (3\/8\" NPT) \/ WS (Water Separator)","offer_id":54513255743763,"sku":"8102374664","price":588.0,"currency_code":"USD","in_stock":true},{"title":"150 SCFM (3\/8\" NPT) \/ M25 (25 Micron)","offer_id":54513255776531,"sku":"G50N0150M25","price":588.0,"currency_code":"USD","in_stock":true},{"title":"150 SCFM (3\/8\" NPT) \/ M5 (5 Micron)","offer_id":54513255809299,"sku":"G50N0150M5","price":588.0,"currency_code":"USD","in_stock":true},{"title":"150 SCFM (3\/8\" NPT) \/ M1 (1 Micron)","offer_id":54513255842067,"sku":"8102374637","price":588.0,"currency_code":"USD","in_stock":true},{"title":"150 SCFM (3\/8\" NPT) \/ M01 (0.01 Micron)","offer_id":54513255874835,"sku":"8102374646","price":588.0,"currency_code":"USD","in_stock":true},{"title":"150 SCFM (3\/8\" NPT) \/ AC (Activated Carbon)","offer_id":54513255907603,"sku":"8102374655","price":588.0,"currency_code":"USD","in_stock":true},{"title":"265 SCFM (1\/2\" NPT) \/ WS (Water Separator)","offer_id":54513255940371,"sku":"8102374665","price":686.0,"currency_code":"USD","in_stock":true},{"title":"265 SCFM (1\/2\" NPT) \/ M25 (25 Micron)","offer_id":54513255973139,"sku":"G50N0265M25","price":686.0,"currency_code":"USD","in_stock":true},{"title":"265 SCFM (1\/2\" NPT) \/ M5 (5 Micron)","offer_id":54513256005907,"sku":"G50N0265M5","price":686.0,"currency_code":"USD","in_stock":true},{"title":"265 SCFM (1\/2\" NPT) \/ M1 (1 Micron)","offer_id":54513256038675,"sku":"8102374638","price":686.0,"currency_code":"USD","in_stock":true},{"title":"265 SCFM (1\/2\" NPT) \/ M01 (0.01 Micron)","offer_id":54513256071443,"sku":"8102374647","price":686.0,"currency_code":"USD","in_stock":true},{"title":"265 SCFM (1\/2\" NPT) \/ AC (Activated Carbon)","offer_id":54513256104211,"sku":"8102374656","price":686.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (3\/4\" NPT) \/ WS (Water Separator)","offer_id":54513256136979,"sku":"8102374666","price":845.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (3\/4\" NPT) \/ M25 (25 Micron)","offer_id":54513256169747,"sku":"G50N0325M25","price":845.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (3\/4\" NPT) \/ M5 (5 Micron)","offer_id":54513256202515,"sku":"G50N0325M5","price":845.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (3\/4\" NPT) \/ M1 (1 Micron)","offer_id":54513256235283,"sku":"8102374639","price":845.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (3\/4\" NPT) \/ M01 (0.01 Micron)","offer_id":54513256268051,"sku":"8102374648","price":845.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (3\/4\" NPT) \/ AC (Activated Carbon)","offer_id":54513256300819,"sku":"8102374657","price":845.0,"currency_code":"USD","in_stock":true},{"title":"490 SCFM (1\" NPT) \/ WS (Water Separator)","offer_id":54513256333587,"sku":"8102374667","price":1102.0,"currency_code":"USD","in_stock":true},{"title":"490 SCFM (1\" NPT) \/ M25 (25 Micron)","offer_id":54513256366355,"sku":"G50N0490M25","price":1102.0,"currency_code":"USD","in_stock":true},{"title":"490 SCFM (1\" NPT) \/ M5 (5 Micron)","offer_id":54513256399123,"sku":"G50N0490M5","price":1102.0,"currency_code":"USD","in_stock":true},{"title":"490 SCFM (1\" NPT) \/ M1 (1 Micron)","offer_id":54513256431891,"sku":"8102374640","price":1102.0,"currency_code":"USD","in_stock":true},{"title":"490 SCFM (1\" NPT) \/ M01 (0.01 Micron)","offer_id":54513256464659,"sku":"8102374649","price":1102.0,"currency_code":"USD","in_stock":true},{"title":"490 SCFM (1\" NPT) \/ AC (Activated Carbon)","offer_id":54513256497427,"sku":"8102374658","price":1102.0,"currency_code":"USD","in_stock":true},{"title":"735 SCFM (1-1\/2\" NPT) \/ M25 (25 Micron)","offer_id":54513256530195,"sku":"G50N0735M25","price":1433.0,"currency_code":"USD","in_stock":true},{"title":"735 SCFM (1-1\/2\" NPT) \/ M5 (5 Micron)","offer_id":54513256562963,"sku":"G50N0735M5","price":1433.0,"currency_code":"USD","in_stock":true},{"title":"735 SCFM (1-1\/2\" NPT) \/ M1 (1 Micron)","offer_id":54513256595731,"sku":"8102374641","price":1433.0,"currency_code":"USD","in_stock":true},{"title":"735 SCFM (1-1\/2\" NPT) \/ M01 (0.01 Micron)","offer_id":54513256628499,"sku":"8102374650","price":1433.0,"currency_code":"USD","in_stock":true},{"title":"735 SCFM (1-1\/2\" NPT) \/ AC (Activated Carbon)","offer_id":54513256661267,"sku":"8102374659","price":1433.0,"currency_code":"USD","in_stock":true},{"title":"1015 SCFM (1-1\/2\" NPT) \/ WS (Water Separator)","offer_id":54513256694035,"sku":"8102374669","price":1719.0,"currency_code":"USD","in_stock":true},{"title":"1015 SCFM (1-1\/2\" NPT) \/ M25 (25 Micron)","offer_id":54513256726803,"sku":"G50N1015M25","price":1719.0,"currency_code":"USD","in_stock":true},{"title":"1015 SCFM (1-1\/2\" NPT) \/ M5 (5 Micron)","offer_id":54513256759571,"sku":"G50N1015M5","price":1719.0,"currency_code":"USD","in_stock":true},{"title":"1015 SCFM (1-1\/2\" NPT) \/ M1 (1 Micron)","offer_id":54513256792339,"sku":"8102374642","price":1719.0,"currency_code":"USD","in_stock":true},{"title":"1015 SCFM (1-1\/2\" NPT) \/ M01 (0.01 Micron)","offer_id":54513256825107,"sku":"8102374651","price":1719.0,"currency_code":"USD","in_stock":true},{"title":"1015 SCFM (1-1\/2\" NPT) \/ AC (Activated Carbon)","offer_id":54513256857875,"sku":"8102374660","price":1719.0,"currency_code":"USD","in_stock":true},{"title":"1135 SCFM (2\" NPT) \/ WS (Water Separator)","offer_id":54513256890643,"sku":"8102374670","price":2067.0,"currency_code":"USD","in_stock":true},{"title":"1135 SCFM (2\" NPT) \/ M25 (25 Micron)","offer_id":54513256923411,"sku":"1280807802","price":2067.0,"currency_code":"USD","in_stock":true},{"title":"1135 SCFM (2\" NPT) \/ M5 (5 Micron)","offer_id":54513256956179,"sku":"G50N1135M5","price":2067.0,"currency_code":"USD","in_stock":true},{"title":"1135 SCFM (2\" NPT) \/ M1 (1 Micron)","offer_id":54513256988947,"sku":"8102374643","price":2067.0,"currency_code":"USD","in_stock":true},{"title":"1135 SCFM (2\" NPT) \/ M01 (0.01 Micron)","offer_id":54513257021715,"sku":"8102374652","price":2067.0,"currency_code":"USD","in_stock":true},{"title":"1135 SCFM (2\" NPT) \/ AC (Activated Carbon)","offer_id":54513257054483,"sku":"8102374661","price":2067.0,"currency_code":"USD","in_stock":true},{"title":"1885 SCFM (2\" NPT) \/ WS (Water Separator)","offer_id":54513257087251,"sku":"8102374671","price":2505.0,"currency_code":"USD","in_stock":true},{"title":"1885 SCFM (2\" NPT) \/ M25 (25 Micron)","offer_id":54513257120019,"sku":"G50N1885M25","price":2505.0,"currency_code":"USD","in_stock":true},{"title":"1885 SCFM (2\" NPT) \/ M5 (5 Micron)","offer_id":54513257152787,"sku":"G50N1885M5","price":2505.0,"currency_code":"USD","in_stock":true},{"title":"1885 SCFM (2\" NPT) \/ M1 (1 Micron)","offer_id":54513257185555,"sku":"8102374644","price":2505.0,"currency_code":"USD","in_stock":true},{"title":"1885 SCFM (2\" NPT) \/ M01 (0.01 Micron)","offer_id":54513257218323,"sku":"8102374653","price":2505.0,"currency_code":"USD","in_stock":true},{"title":"1885 SCFM (2\" NPT) \/ AC (Activated Carbon)","offer_id":54513257251091,"sku":"8102374662","price":2505.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/g50n-mid-pressure-aluminum-filter-by-nano.png?v=1785415614"},{"product_id":"nfz-high-capacity-flanged-compressed-air-filter-by-nano","title":"NFZ High-Capacity Flanged Compressed Air Filter By Nano","description":"\u003cp\u003eThe nano NFZ high-capacity flanged filters are fabricated carbon steel compressed air and gas filters engineered for reliable liquid and particulate removal at low pressure drop in high-flow industrial systems. This is the Z-flow configuration of the F2 range, covering nine models from 2500 to 10000 SCFM at 100 psig with 4\" to 10\" ANSI flanged connections. Each housing is built in accordance with ASME VIII with U-Stamp approval, manufactured in an ISO 9001 facility and tested to ISO 12500. Externally primed and powder coated for corrosion resistance, the NFZ is the workhorse filter for compressor rooms, gas treatment skids and other bulk-flow applications where high capacity and durability matter.\u003c\/p\u003e\n\u003ch3\u003eHow to select your NFZ filter\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMatch the model to your flow and flange size. Choose the NFZ rated at or above your actual SCFM at 100 psig, from NFZ 2500 (2500 SCFM, 4\" flange) up to NFZ 10000 (10000 SCFM, 10\" flange).\u003c\/li\u003e\n\u003cli\u003eChoose the element grade for the air quality you need. Use M1 (1 micron) for general particulate and coalescing duty, M01 (0.01 micron) for high-efficiency coalescing, and AC activated carbon for oil vapor and odor removal.\u003c\/li\u003e\n\u003cli\u003eStage filters in series for critical air. A common train is an M1 coalescer, then an M01 high-efficiency coalescer, then an AC carbon filter for vapor-free air.\u003c\/li\u003e\n\u003cli\u003eConfirm your operating temperature. M1 and M01 grades run 35 to 212 F recommended; AC carbon grade is rated 35 to 77 F recommended.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-capacity fabricated carbon steel housing for high-flow duty from 2500 to 10000 SCFM.\u003c\/li\u003e\n\u003cli\u003eZ-flow configuration with 4\" to 10\" ANSI flanged inlet and outlet.\u003c\/li\u003e\n\u003cli\u003eBuilt in accordance with ASME VIII with U-Stamp approval.\u003c\/li\u003e\n\u003cli\u003eManufactured in an ISO 9001 facility and tested to ISO 12500.\u003c\/li\u003e\n\u003cli\u003eExternally primed and powder coated for optimum corrosion resistance.\u003c\/li\u003e\n\u003cli\u003eElements compatible with synthetic lubricants, with an outer drainage layer that prevents carryover.\u003c\/li\u003e\n\u003cli\u003eThree interchangeable element grades (M1, M01, AC) for tailored air quality.\u003c\/li\u003e\n\u003cli\u003eHigh pressure and stainless steel options available on request.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal flow: 2500 to 10000 SCFM at 100 psig.\u003c\/li\u003e\n\u003cli\u003eConnections: 4\", 6\", 8\" and 10\" ANSI flanged depending on model.\u003c\/li\u003e\n\u003cli\u003eFlow configuration: Z-flow (F2 range).\u003c\/li\u003e\n\u003cli\u003eHousing: fabricated carbon steel, externally primed and powder coated, ASME VIII with U-Stamp.\u003c\/li\u003e\n\u003cli\u003eReplacement element: E 0853 series (aluminum end cap) by grade.\u003c\/li\u003e\n\u003cli\u003eGrade M1: 1 micron particulate and coalescing, max oil carryover 0.1 ppm, design temp 35 to 248 F.\u003c\/li\u003e\n\u003cli\u003eGrade M01: 0.01 micron coalescing, max oil carryover 0.01 ppm, design temp 35 to 248 F.\u003c\/li\u003e\n\u003cli\u003eGrade AC: activated carbon, oil vapor removal to 0.003 ppm at 68 F, design temp 35 to 122 F.\u003c\/li\u003e\n\u003cli\u003eTested in accordance with ISO 12500; ISO 8573-1 air quality classes per grade.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIdeal applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge compressor rooms and central compressed air systems.\u003c\/li\u003e\n\u003cli\u003eBiogas, landfill gas and process gas treatment skids.\u003c\/li\u003e\n\u003cli\u003eBulk water, oil aerosol and particulate removal in high-flow lines.\u003c\/li\u003e\n\u003cli\u003ePower generation, chemical, and heavy manufacturing plants.\u003c\/li\u003e\n\u003cli\u003eAny high-flow application needing durable, low pressure drop filtration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the NFZ and NFT filters?\u003c\/strong\u003e Both are F2 high-capacity flanged filters. The NFZ uses a Z-flow (offset) porting arrangement and the NFT uses a T-flow (inline) arrangement. Choose the one that best fits your piping layout; the filtration grades and elements are the same.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich grade removes oil vapor?\u003c\/strong\u003e The AC activated carbon grade removes oil vapor and odors down to 0.003 ppm and is installed downstream of coalescing filters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich model do I need?\u003c\/strong\u003e Select the model whose SCFM rating at 100 psig meets or exceeds your actual flow and whose flange matches your piping, from 2500 SCFM (4\" flange) to 10000 SCFM (10\" flange).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre these pressure vessels code stamped?\u003c\/strong\u003e Yes. NFZ housings are fabricated in accordance with ASME VIII and carry a U-Stamp.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I get a high-pressure or stainless steel version?\u003c\/strong\u003e Yes. High pressure and stainless steel options are available on request.\u003c\/p\u003e\n\u003cp\u003eSpecifications are drawn from the nano F2 NFZ\/NFT datasheet and are for general reference only. Confirm final selection against the current nano product brochure and user guide.\u003c\/p\u003e","brand":"Nano","offers":[{"title":"2500 SCFM (4\" Flange) \/ M1 (1 Micron)","offer_id":54513889706259,"sku":"8102460011","price":6700.0,"currency_code":"USD","in_stock":true},{"title":"2500 SCFM (4\" Flange) \/ M01 (0.01 Micron)","offer_id":54513889739027,"sku":"8102460000","price":6700.0,"currency_code":"USD","in_stock":true},{"title":"2500 SCFM (4\" Flange) \/ AC (Activated Carbon)","offer_id":54513889771795,"sku":"NFZ2500AC","price":6700.0,"currency_code":"USD","in_stock":true},{"title":"3000 SCFM (4\" Flange) \/ M1 (1 Micron)","offer_id":54513889804563,"sku":"8102460031","price":7138.0,"currency_code":"USD","in_stock":true},{"title":"3000 SCFM (4\" Flange) \/ M01 (0.01 Micron)","offer_id":54513889837331,"sku":"8102460020","price":7138.0,"currency_code":"USD","in_stock":true},{"title":"3000 SCFM (4\" Flange) \/ AC (Activated Carbon)","offer_id":54513889870099,"sku":"NFZ3000AC","price":7138.0,"currency_code":"USD","in_stock":true},{"title":"3500 SCFM (6\" Flange) \/ M1 (1 Micron)","offer_id":54513889902867,"sku":"8102460051","price":7138.0,"currency_code":"USD","in_stock":true},{"title":"3500 SCFM (6\" Flange) \/ M01 (0.01 Micron)","offer_id":54513889935635,"sku":"8102460040","price":7138.0,"currency_code":"USD","in_stock":true},{"title":"3500 SCFM (6\" Flange) \/ AC (Activated Carbon)","offer_id":54513889968403,"sku":"NFZ3500AC","price":7138.0,"currency_code":"USD","in_stock":true},{"title":"4000 SCFM (6\" Flange) \/ M1 (1 Micron)","offer_id":54513890001171,"sku":"8102460071","price":7803.0,"currency_code":"USD","in_stock":true},{"title":"4000 SCFM (6\" Flange) \/ M01 (0.01 Micron)","offer_id":54513890033939,"sku":"8102460060","price":7803.0,"currency_code":"USD","in_stock":true},{"title":"4000 SCFM (6\" Flange) \/ AC (Activated Carbon)","offer_id":54513890066707,"sku":"NFZ4000AC","price":7803.0,"currency_code":"USD","in_stock":true},{"title":"5000 SCFM (6\" Flange) \/ M1 (1 Micron)","offer_id":54513890099475,"sku":"8102460091","price":10664.0,"currency_code":"USD","in_stock":true},{"title":"5000 SCFM (6\" Flange) \/ M01 (0.01 Micron)","offer_id":54513890132243,"sku":"8102460080","price":10664.0,"currency_code":"USD","in_stock":true},{"title":"5000 SCFM (6\" Flange) \/ AC (Activated Carbon)","offer_id":54513890165011,"sku":"NFZ5000AC","price":10664.0,"currency_code":"USD","in_stock":true},{"title":"6000 SCFM (6\" Flange) \/ M1 (1 Micron)","offer_id":54513890197779,"sku":"8102460111","price":11104.0,"currency_code":"USD","in_stock":true},{"title":"6000 SCFM (6\" Flange) \/ M01 (0.01 Micron)","offer_id":54513890230547,"sku":"8102460100","price":11104.0,"currency_code":"USD","in_stock":true},{"title":"6000 SCFM (6\" Flange) \/ AC (Activated Carbon)","offer_id":54513890263315,"sku":"NFZ6000AC","price":11104.0,"currency_code":"USD","in_stock":true},{"title":"7500 SCFM (8\" Flange) \/ M1 (1 Micron)","offer_id":54513890296083,"sku":"8102460131","price":12699.0,"currency_code":"USD","in_stock":true},{"title":"7500 SCFM (8\" Flange) \/ M01 (0.01 Micron)","offer_id":54513890328851,"sku":"8102460120","price":12699.0,"currency_code":"USD","in_stock":true},{"title":"7500 SCFM (8\" Flange) \/ AC (Activated Carbon)","offer_id":54513890361619,"sku":"NFZ7500AC","price":12699.0,"currency_code":"USD","in_stock":true},{"title":"8500 SCFM (8\" Flange) \/ M1 (1 Micron)","offer_id":54513890394387,"sku":"8102460151","price":13145.0,"currency_code":"USD","in_stock":true},{"title":"8500 SCFM (8\" Flange) \/ M01 (0.01 Micron)","offer_id":54513890427155,"sku":"8102460140","price":13145.0,"currency_code":"USD","in_stock":true},{"title":"8500 SCFM (8\" Flange) \/ AC (Activated Carbon)","offer_id":54513890459923,"sku":"NFZ8500AC","price":13145.0,"currency_code":"USD","in_stock":true},{"title":"10000 SCFM (10\" Flange) \/ M1 (1 Micron)","offer_id":54513890492691,"sku":"8102460171","price":16765.0,"currency_code":"USD","in_stock":true},{"title":"10000 SCFM (10\" Flange) \/ M01 (0.01 Micron)","offer_id":54513890525459,"sku":"8102460160","price":16765.0,"currency_code":"USD","in_stock":true},{"title":"10000 SCFM (10\" Flange) \/ AC (Activated Carbon)","offer_id":54513890558227,"sku":"NFZ10000AC","price":16765.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/nfz-high-capacity-flanged-filter-by-nano.png?v=1785435255"},{"product_id":"super-dry-felt-pad-d-series","title":"Super-Dry Replacement Felt Filtration Pad for D Series Desiccant Air Dryers","description":"\u003cp\u003eFelt pads are one of the filtration layers inside a Super-Dry D Series single-tower desiccant dryer. They sit with the polypropylene coalescer element and the stainless steel grids in the stage that removes solid particulates before the air ever reaches the desiccant. Order by dryer model, with a single pad covering both the D2 and the D3.\u003c\/p\u003e\n\u003ch3\u003eHow it works\u003c\/h3\u003e\n\u003cp\u003eWet compressed air enters the D Series through an offset inlet that throws water droplets out by centrifugal action. The air then passes around the coalescer element, the felt pads and the stainless steel grids, which together take out solid particulates, before it flows upward through the sewed desiccant bag that absorbs the remaining moisture. Felt is a consumable layer, so fit fresh pads whenever you change the cartridge and the desiccant bag, not on their own schedule.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eFits Model\u003c\/th\u003e\n\u003cth\u003eMedia\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e280-430\u003c\/td\u003e\n\u003ctd\u003eFELTD1\u003c\/td\u003e\n\u003ctd\u003eD1\u003c\/td\u003e\n\u003ctd\u003eFelt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e280-431\u003c\/td\u003e\n\u003ctd\u003eFELTD2-D3\u003c\/td\u003e\n\u003ctd\u003eD2 or D3\u003c\/td\u003e\n\u003ctd\u003eFelt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e280-432\u003c\/td\u003e\n\u003ctd\u003eFELTD4\u003c\/td\u003e\n\u003ctd\u003eD4\u003c\/td\u003e\n\u003ctd\u003eFelt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eD Series cartridge changes, with fresh pads fitted alongside the desiccant bag\u003c\/li\u003e\n\u003cli\u003eRenewing the particulate stage together with the coalescer element and stainless steel grids\u003c\/li\u003e\n\u003cli\u003ePaint shops and spray finishing lines\u003c\/li\u003e\n\u003cli\u003eSandblasting and abrasive blasting\u003c\/li\u003e\n\u003cli\u003ePlasma cutting\u003c\/li\u003e\n\u003cli\u003eGeneral manufacturing and pneumatic tool air\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFresh felt pads keep the particulate stage of a D Series dryer doing its share of the work, which is what protects the desiccant bag and the air quality downstream. Warthog Air Compressor Store is an authorized US source for Super-Dry Systems Inc. We carry the D Series service parts range alongside the dryers.\u003c\/p\u003e","brand":"Super-Dry","offers":[{"title":"FELTD1","offer_id":54594669052179,"sku":"280-430","price":9.87,"currency_code":"USD","in_stock":true},{"title":"FELTD2-D3","offer_id":54594669084947,"sku":"280-431","price":10.77,"currency_code":"USD","in_stock":true},{"title":"FELTD4","offer_id":54594669117715,"sku":"280-432","price":14.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/super-dry-feltd1-280-430-01.jpg?v=1787264223"},{"product_id":"super-dry-osd-outlet-screen-d-series","title":"Super-Dry OSD Replacement Outlet Screen for D Series Single-Tower Air Dryers","description":"\u003cp\u003eThe OSD outlet screen is a service part for the outlet end of a Super-Dry D Series single-tower desiccant dryer. Super-Dry supplies it for the two larger models in the range, the D3 and the D4. It is the kind of part worth replacing during a cartridge change rather than after it has already caused a restriction.\u003c\/p\u003e\n\u003ch3\u003eHow it works\u003c\/h3\u003e\n\u003cp\u003eA D Series dryer finishes its cycle with a second stage of filtration that removes desiccant dust before the air leaves the housing, the last step after the coalescer element, felt pads, stainless steel grids and sewed desiccant bag have done their work. The outlet screen belongs to the hardware at that end of the dryer. Because the housing opens at the stainless steel clamp, you can inspect the screen every time you change the cartridge, and replace it if it is damaged, deformed or blocked.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eFits Model\u003c\/th\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e280-600\u003c\/td\u003e\n\u003ctd\u003eOSD3\u003c\/td\u003e\n\u003ctd\u003eD3\u003c\/td\u003e\n\u003ctd\u003eDryer outlet end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e280-601\u003c\/td\u003e\n\u003ctd\u003eOSD4\u003c\/td\u003e\n\u003ctd\u003eD4\u003c\/td\u003e\n\u003ctd\u003eDryer outlet end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eD3 and D4 cartridge changes, where the outlet hardware is inspected with the housing open\u003c\/li\u003e\n\u003cli\u003eReplacing an outlet screen that is damaged, deformed or blocked\u003c\/li\u003e\n\u003cli\u003ePaint shops and spray finishing lines\u003c\/li\u003e\n\u003cli\u003eSandblasting and abrasive blasting\u003c\/li\u003e\n\u003cli\u003ePlasma cutting\u003c\/li\u003e\n\u003cli\u003eGeneral manufacturing and pneumatic tool air\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOrdering the OSD screen with the rest of your D3 or D4 cartridge parts means one service visit instead of two when the outlet hardware needs attention. Warthog Air Compressor Store is an authorized US source for Super-Dry Systems Inc. We carry the D Series service parts range alongside the dryers.\u003c\/p\u003e","brand":"Super-Dry","offers":[{"title":"OSD3","offer_id":54594669347091,"sku":"280-600","price":53.85,"currency_code":"USD","in_stock":true},{"title":"OSD4","offer_id":54594669379859,"sku":"280-601","price":63.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/super-dry-osd3-280-600-01.jpg?v=1787264252"},{"product_id":"super-dry-fsd-series-centrifugal-water-separator","title":"Super-Dry FSD Series Centrifugal Water Separator, 45 to 515 SCFM, 1\/2\" to 2\" NPT","description":"\u003cp\u003eThe Super-Dry FSD Series is a centrifugal water separator that pulls bulk liquid water out of a compressed air line before it reaches your dryer, your filters or your tools. Five models cover 45 to 515 SCFM at 100 PSIG with 1\/2\" to 2\" NPT inlet and outlet ports, so you can size the separator to the pipe you already run. It is built for shops that see slugs of condensate coming off an aftercooler or air receiver and want that water out of the system.\u003c\/p\u003e\n\u003ch3\u003eHow it works\u003c\/h3\u003e\n\u003cp\u003eCompressed air enters the housing and passes an internal spinner that forces it into a tight rotating path. The liquid droplets are heavier than the air carrying them, so centrifugal action throws them against the vessel wall, where they run down and collect in the bowl. A built-in float drain discharges that condensate automatically, and a timer drain is offered as an option. Install an FSD separator downstream of an aftercooler or air receiver and upstream of a compressed air dryer.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eAirflow at 100 PSIG\u003c\/th\u003e\n\u003cth\u003eInlet \/ Outlet Ports\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-100\u003c\/td\u003e\n\u003ctd\u003eFSD-45-W\u003c\/td\u003e\n\u003ctd\u003e45 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-110\u003c\/td\u003e\n\u003ctd\u003eFSD-85-W\u003c\/td\u003e\n\u003ctd\u003e85 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-120\u003c\/td\u003e\n\u003ctd\u003eFSD-185-W\u003c\/td\u003e\n\u003ctd\u003e185 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-130\u003c\/td\u003e\n\u003ctd\u003eFSD-375-W\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-140\u003c\/td\u003e\n\u003ctd\u003eFSD-515-W\u003c\/td\u003e\n\u003ctd\u003e515 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe published limits shown here apply to the FSD-45-W only: a maximum inlet pressure of 232 PSIG and a maximum inlet temperature of 176°F (80°C). Super-Dry does not publish separate pressure or temperature limits for the four larger separators. Every separator in the series ships with the float drain and the internal spinner in place, and Super-Dry rates the FSD housings for excellent liquid removal efficiencies at all flow conditions.\u003c\/p\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBulk water knockout ahead of a refrigerated or desiccant air dryer\u003c\/li\u003e\n\u003cli\u003eDownstream of an aftercooler or air receiver where condensate collects\u003c\/li\u003e\n\u003cli\u003ePaint booths and spray finishing lines that cannot tolerate water carryover\u003c\/li\u003e\n\u003cli\u003eSandblasting and abrasive blast cabinets\u003c\/li\u003e\n\u003cli\u003ePlant air headers feeding pneumatic tools and air motors\u003c\/li\u003e\n\u003cli\u003ePoint of use protection for pneumatic controls, valves and cylinders\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFSD Series separator housing with internal spinner\u003c\/li\u003e\n\u003cli\u003eBuilt-in float drain (timer drain available as an option)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FSD Series gives compressed air systems a straightforward mechanical first stage of liquid removal, which keeps dryers, filters and downstream air tools working in the condition they were designed for. Warthog Air Compressor Store is an authorized US source for Super-Dry Systems Inc. We can help you match model to pipe size and flow.\u003c\/p\u003e","brand":"Super-Dry","offers":[{"title":"FSD-45-W","offer_id":54594671214867,"sku":"330-100","price":354.49,"currency_code":"USD","in_stock":true},{"title":"FSD-85-W","offer_id":54594671247635,"sku":"330-110","price":444.23,"currency_code":"USD","in_stock":true},{"title":"FSD-185-W","offer_id":54594671280403,"sku":"330-120","price":596.79,"currency_code":"USD","in_stock":true},{"title":"FSD-375-W","offer_id":54594671313171,"sku":"330-130","price":690.13,"currency_code":"USD","in_stock":true},{"title":"FSD-515-W","offer_id":54594671345939,"sku":"330-140","price":1099.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/super-dry-fsd-45-w-330-100-01.jpg?v=1787264379"},{"product_id":"super-dry-scd-stainless-steel-grid-d-series","title":"Super-Dry SCD Stainless Steel Filtration Grid for D Series Desiccant Air Dryers","description":"\u003cp\u003eThe SCD stainless steel grid is one of the filtration components inside a Super-Dry D Series single-tower desiccant dryer. It works alongside the polypropylene coalescer element and the felt pads in the stage that strips solid particulates out of the air before it reaches the desiccant. Order the grid that matches your dryer, with one part covering both the D2 and the D3.\u003c\/p\u003e\n\u003ch3\u003eHow it works\u003c\/h3\u003e\n\u003cp\u003eWet compressed air enters the D Series through an offset inlet that spins water droplets out by centrifugal action, then passes around the coalescer element, the felt pads and the stainless steel grids to remove solid particulates. From there the air flows upward through the sewed desiccant bag and out through a second stage of filtration that catches desiccant dust. Because the grid is stainless, it is the reusable part of that stack, so replace it when it is deformed, blinded or damaged during a cartridge change rather than on a fixed schedule.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eFits Model\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e280-305\u003c\/td\u003e\n\u003ctd\u003eSCD1\u003c\/td\u003e\n\u003ctd\u003eD1\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e280-306\u003c\/td\u003e\n\u003ctd\u003eSCD2-D3\u003c\/td\u003e\n\u003ctd\u003eD2 or D3\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e280-307\u003c\/td\u003e\n\u003ctd\u003eSCD4\u003c\/td\u003e\n\u003ctd\u003eD4\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eD Series cartridge service, replacing a grid that is deformed, blinded or damaged\u003c\/li\u003e\n\u003cli\u003eRebuilding the particulate stage alongside the coalescer element and felt pads\u003c\/li\u003e\n\u003cli\u003ePaint shops and spray finishing lines\u003c\/li\u003e\n\u003cli\u003eSandblasting and abrasive blasting\u003c\/li\u003e\n\u003cli\u003ePlasma cutting\u003c\/li\u003e\n\u003cli\u003eGeneral manufacturing and pneumatic tool air\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeeping an SCD grid on the shelf means a damaged one never turns a routine D Series cartridge change into downtime for a paint booth or blast room. Warthog Air Compressor Store is an authorized US source for Super-Dry Systems Inc. We stock the D Series service parts range alongside the dryers.\u003c\/p\u003e","brand":"Super-Dry","offers":[{"title":"SCD1","offer_id":54594671444243,"sku":"280-305","price":11.67,"currency_code":"USD","in_stock":true},{"title":"SCD2-D3","offer_id":54594671477011,"sku":"280-306","price":14.36,"currency_code":"USD","in_stock":true},{"title":"SCD4","offer_id":54594671509779,"sku":"280-307","price":20.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/super-dry-scd1-280-305-01.jpg?v=1787264395"},{"product_id":"super-dry-fsd-series-water-separator-replacement-element","title":"Super-Dry FSD Series Water Separator Replacement Element, Fits FSD-45-W to FSD-515-W","description":"\u003cp\u003eThis is the replacement internal deflector element for Super-Dry FSD Series centrifugal water separators. Each element is matched to one separator model, from the FSD-45-W up to the FSD-515-W, so the airflow path through the housing stays the way the separator was designed to run. Order it when you are servicing a separator or keeping a spare on the shelf for a line you cannot afford to shut down.\u003c\/p\u003e\n\u003ch3\u003eHow it works\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe deflector sets the rotating flow path inside the separator housing, which is what throws bulk liquid out of the air stream.\u003c\/li\u003e\n\u003cli\u003eRated to remove up to 99% of bulk liquids from the compressed air passing through it.\u003c\/li\u003e\n\u003cli\u003eNo moving parts, so it runs maintenance free between service intervals.\u003c\/li\u003e\n\u003cli\u003eBuilt for the operating conditions the FSD housings see in industrial plant air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003cth\u003eFits Separator\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-105\u003c\/td\u003e\n\u003ctd\u003eE-45-W\u003c\/td\u003e\n\u003ctd\u003eFSD-45-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-115\u003c\/td\u003e\n\u003ctd\u003eE-85-W\u003c\/td\u003e\n\u003ctd\u003eFSD-85-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-125\u003c\/td\u003e\n\u003ctd\u003eE-185-W\u003c\/td\u003e\n\u003ctd\u003eFSD-185-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-135\u003c\/td\u003e\n\u003ctd\u003eE-375-W\u003c\/td\u003e\n\u003ctd\u003eFSD-375-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330-145\u003c\/td\u003e\n\u003ctd\u003eE-515-W\u003c\/td\u003e\n\u003ctd\u003eFSD-515-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSelect the element by the separator model it goes into. Elements are not interchangeable between housing sizes.\u003c\/p\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eScheduled service of an installed FSD Series water separator\u003c\/li\u003e\n\u003cli\u003eRestoring separation efficiency on a line that has started passing water\u003c\/li\u003e\n\u003cli\u003eSpares stock for facilities holding tight air quality standards\u003c\/li\u003e\n\u003cli\u003ePaint and finishing systems where moisture carryover ruins the work\u003c\/li\u003e\n\u003cli\u003eProtecting dryers, filters and pneumatic tools from water damage\u003c\/li\u003e\n\u003cli\u003eSandblasting and other high demand air uses that run wet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeeping a fresh deflector in an FSD Series separator is the cheapest way to protect the dryers, filters and air tools sitting downstream of it. Warthog Air Compressor Store is an authorized US source for Super-Dry Systems Inc. We can confirm which element matches the separator you have in service.\u003c\/p\u003e","brand":"Super-Dry","offers":[{"title":"E-45-W","offer_id":54594671902995,"sku":"330-105","price":141.79,"currency_code":"USD","in_stock":true},{"title":"E-85-W","offer_id":54594671935763,"sku":"330-115","price":183.08,"currency_code":"USD","in_stock":true},{"title":"E-185-W","offer_id":54594671968531,"sku":"330-125","price":268.33,"currency_code":"USD","in_stock":true},{"title":"E-375-W","offer_id":54594672001299,"sku":"330-135","price":361.67,"currency_code":"USD","in_stock":true},{"title":"E-515-W","offer_id":54594672034067,"sku":"330-145","price":423.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/super-dry-e-45-w-330-105-01.jpg?v=1787264421"},{"product_id":"champion-cfl-series-grade-c-particulate-inline-filter","title":"Champion CFL Series Inline Air Filter – Grade C General Purpose Particulate (20–780 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series Grade C\u003c\/strong\u003e is a \u003cstrong\u003egeneral-purpose particulate inline filter\u003c\/strong\u003e available in ten flow rates from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e, engineered to remove solid contaminants from compressed air streams before they reach your dryer, downstream coalescing filters, or point-of-use tools. Built for working pressures up to \u003cstrong\u003e300 PSIG\u003c\/strong\u003e, the Grade C is the workhorse pre-filter in the Champion CFL family and a critical first line of defense in any compressed-air treatment train.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and connection size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhy Compressed Air Filtration Matters\u003c\/h2\u003e\u003cp\u003eAtmospheric air pulled into a compressor carries dust, pollen, rust scale, pipe debris, and microscopic abrasive particles. The compression process concentrates those contaminants by a factor of 7× to 10×. Left unfiltered, that grit erodes valves, scores cylinder walls in pneumatic actuators, blinds dryer heat exchangers, contaminates paint finishes, and shortens the service life of every \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/coalescing-filters-elements\"\u003edownstream coalescing element\u003c\/a\u003e. Installing a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/particulate-removal-filters\"\u003eGrade C particulate filter\u003c\/a\u003e as your first stage of treatment protects every piece of capital equipment that follows.\u003c\/p\u003e\u003ch2\u003eISO 8573-1:2010 Air Quality Performance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid Particles: ISO 8573-1 Class 2\u003c\/strong\u003e — No particle larger than 1 micron.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemaining Oil Content: ISO 8573-1 Class 4\u003c\/strong\u003e — Bulk oil and oil aerosol removal sufficient for general industrial use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis makes the Grade C an ideal pre-filter ahead of a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/refrigerated-air-dryers\"\u003erefrigerated air dryer\u003c\/a\u003e, a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/desiccant-air-dryers\"\u003edesiccant tower\u003c\/a\u003e, or a \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E high-efficiency coalescing filter\u003c\/a\u003e for applications requiring instrument-quality air.\u003c\/p\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL20C11APYTW\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e4.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL35C13APYTW\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8.1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL60C13APYTW\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL100C17AGYTW\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e6.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL170C17AGYTW\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e6.9 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL250C21AGYTW\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e10.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL375C21AGYTW\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e11.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL485C23AGYTW\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625C25AGYTW\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e33 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL780C25AGYTW\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e38 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrade C General Purpose Element\u003c\/strong\u003e — Removes particulates down to 1 micron at high efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 to 780 SCFM Rated Flow\u003c\/strong\u003e — Ten sizes covering shop compressors through large industrial plant air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e — High-pressure rating for demanding industrial systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e — Withstands hot air directly off a reciprocating compressor when paired with proper cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Cast Aluminum Housing\u003c\/strong\u003e — Corrosion-resistant, hydrostatically tested at the factory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Indicator\u003c\/strong\u003e — Tells you exactly when the element needs replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Float Drain\u003c\/strong\u003e — Continuously removes collected liquid without operator intervention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Inline Form Factor\u003c\/strong\u003e — Bolts directly into existing plant air piping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-Replaceable Element\u003c\/strong\u003e — Annual filter change keeps the housing in service for decades.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChampion Pneumatic Quality\u003c\/strong\u003e — Backed by over a century of compressed-air engineering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grade\u003c\/td\u003e\n\u003ctd\u003eC — General Purpose Particulate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e20 – 780 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO 8573-1 Solids Class\u003c\/td\u003e\n\u003ctd\u003eClass 2 (1 micron \/ 400,000 particles\/m³)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO 8573-1 Oil Class\u003c\/td\u003e\n\u003ctd\u003eClass 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eAutomatic float drain (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003ePleated borosilicate fiber, replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eCast aluminum, epoxy painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eThe Grade C is the right particulate filter for shops running compressors from 5 HP through large industrial plant air systems, point-of-use polishing on larger systems, plasma-cutter feed lines, paint-prep stations, laboratory air, dry sandblasting cabinets, automotive service bays, and any general industrial application where you need ISO Class 2 solids before the air hits a tool or instrument. Field engineers often install one ahead of a Champion CRH Series refrigerated dryer to protect the dryer heat exchanger from rust scale and pipe debris.\u003c\/p\u003e\u003ch2\u003eBuild Your Filtration Train\u003c\/h2\u003e\u003cp\u003eFor a complete compressed-air treatment system, install filters in series in the following order: (1) \u003cstrong\u003eCFL Grade C particulate filter\u003c\/strong\u003e at the compressor discharge to remove bulk solids; (2) refrigerated or desiccant \u003cstrong\u003edryer\u003c\/strong\u003e to remove moisture; (3) \u003cstrong\u003eCFL Grade E coalescing filter\u003c\/strong\u003e downstream of the dryer to deliver instrument-quality air.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually or whenever the differential-pressure indicator shows a 5 PSID rise across the filter, whichever comes first. Operating with a clogged element wastes compressed-air energy (roughly 1% of compressor horsepower per PSID of pressure drop) and risks element rupture. \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filter-elements\"\u003eChampion replacement elements\u003c\/a\u003e are stocked at Air Compressor Store with same-day shipping.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series filter ships with the full factory warranty, lifetime application support, and access to our certified compressed-air engineers for sizing and system design.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between Grade C and Grade E?\u003c\/h3\u003e\u003cp\u003eGrade C removes solid particulates (rust, dust, pipe scale) and bulk liquid water. Grade E is a high-efficiency coalescing filter that removes oil aerosols, submicron particles, and oil vapor. In a properly designed system, you install Grade C upstream and Grade E downstream.\u003c\/p\u003e\u003ch3\u003eDoes the Grade C remove oil?\u003c\/h3\u003e\u003cp\u003eIt removes bulk oil and oil aerosols to ISO 8573-1 Class 4, which is fine for general industrial work. For paint, food contact, or instrument air, follow it with a CFL Grade E coalescing filter.\u003c\/p\u003e\u003ch3\u003eHow do I choose the right size?\u003c\/h3\u003e\u003cp\u003eSize the filter to the actual SCFM flowing through that point in the system, not to compressor horsepower. When in doubt, size up — an oversized filter runs at lower pressure drop and lasts longer. Call our engineers if you need help.\u003c\/p\u003e\u003ch3\u003eHow often do I change the element?\u003c\/h3\u003e\u003cp\u003eReplace annually or when differential pressure climbs 5 PSID above clean, whichever comes first.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"20 SCFM — 3\/8\" NPTF","offer_id":54604634751251,"sku":"CFL20C11APYTW","price":324.0,"currency_code":"USD","in_stock":true},{"title":"35 SCFM — 1\/2\" NPTF","offer_id":54604634784019,"sku":"CFL35C13APYTW","price":364.5,"currency_code":"USD","in_stock":true},{"title":"60 SCFM — 1\/2\" NPTF","offer_id":54604634816787,"sku":"CFL60C13APYTW","price":453.6,"currency_code":"USD","in_stock":true},{"title":"100 SCFM — 1\" NPTF","offer_id":54604634849555,"sku":"CFL100C17AGYTW","price":550.8,"currency_code":"USD","in_stock":true},{"title":"170 SCFM — 1\" NPTF","offer_id":54604634882323,"sku":"CFL170C17AGYTW","price":777.6,"currency_code":"USD","in_stock":true},{"title":"250 SCFM — 1-1\/2\" NPTF","offer_id":54604634915091,"sku":"CFL250C21AGYTW","price":996.3,"currency_code":"USD","in_stock":true},{"title":"375 SCFM — 1-1\/2\" NPTF","offer_id":54604634947859,"sku":"CFL375C21AGYTW","price":1279.8,"currency_code":"USD","in_stock":true},{"title":"485 SCFM — 2\" NPTF","offer_id":54604634980627,"sku":"CFL485C23AGYTW","price":1563.3,"currency_code":"USD","in_stock":true},{"title":"625 SCFM — 2-1\/2\" NPTF","offer_id":54604635013395,"sku":"CFL625C25AGYTW","price":1838.7,"currency_code":"USD","in_stock":true},{"title":"780 SCFM — 2-1\/2\" NPTF","offer_id":54604635046163,"sku":"CFL780C25AGYTW","price":2097.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL1_c15f9c5f-11b4-4d2e-9c88-5f98a0db18c0.png?v=1787575061"},{"product_id":"champion-cfl-series-grade-e-coalescing-inline-filter","title":"Champion CFL Series Inline Air Filter – Grade E High Efficiency Oil Removal (20–780 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series Grade E\u003c\/strong\u003e is a \u003cstrong\u003ehigh-efficiency coalescing inline filter\u003c\/strong\u003e available in ten flow rates from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e, engineered to remove oil aerosols, oil vapors, and submicron particles from compressed air. Built for working pressures up to \u003cstrong\u003e300 PSIG\u003c\/strong\u003e, the Grade E delivers instrument-quality air to spray booths, food and beverage lines, dental offices, laboratories, and any application where oil contamination cannot be tolerated.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and connection size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhy Coalescing Filtration Matters\u003c\/h2\u003e\u003cp\u003eEven a well-maintained lubricated rotary screw compressor carries 3 to 5 milligrams of oil per cubic meter of air at discharge. \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/refrigerated-air-dryers\"\u003eRefrigerated dryers\u003c\/a\u003e and \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filters\"\u003estandard particulate filters\u003c\/a\u003e remove bulk oil, but a fine mist of submicron oil aerosols and oil vapor passes straight through to your tools, paint guns, and instruments. The result: fisheye in paint finishes, contaminated food product, sticky valves, off-spec lab tests, and rusted, gummed-up pneumatic logic. A Grade E coalescing filter is the only effective way to remove that residual oil aerosol load.\u003c\/p\u003e\u003ch2\u003eISO 8573-1:2010 Air Quality Performance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemaining Oil Aerosol Content: ISO 8573-1 Class 1\u003c\/strong\u003e — ≤ 0.01 mg\/m³ of oil aerosol at 20°C reference conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolid Particles: ISO 8573-1 Class 1\u003c\/strong\u003e — No particle larger than 0.1 micron.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil Removal Efficiency: 99.999%\u003c\/strong\u003e at 0.01 micron particles.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL20E11APYTW\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e4.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL35E13APYTW\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8.1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL60E13APYTW\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL100E17AGYTW\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e6.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL170E17AGYTW\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e6.9 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL250E21AGYTW\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e10.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL375E21AGYTW\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e11.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL485E23AGYTW\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625E25AGYTW\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e33 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL780E25AGYTW\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e38 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrade E High-Efficiency Coalescing Element\u003c\/strong\u003e — 99.999% oil aerosol removal down to 0.01 micron.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 to 780 SCFM Rated Flow\u003c\/strong\u003e — Ten sizes covering shop compressors through large industrial plant air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e — High-pressure rating for demanding industrial systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e — Suitable for installation after a refrigerated dryer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Cast Aluminum Housing\u003c\/strong\u003e — Corrosion-resistant, hydrostatically tested at the factory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Indicator\u003c\/strong\u003e — At-a-glance element replacement signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Float Drain\u003c\/strong\u003e — Continuously removes collected liquid oil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Inline Form Factor\u003c\/strong\u003e — Bolts directly into existing plant air piping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-Replaceable Element\u003c\/strong\u003e — Annual change keeps the housing in service for decades.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChampion Pneumatic Quality\u003c\/strong\u003e — Backed by over a century of compressed-air engineering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow Coalescing Filters Work\u003c\/h2\u003e\u003cp\u003eInside the filter housing, compressed air flows from inside the element outward through a graduated bed of borosilicate microfibers. Microscopic oil aerosols collide with the fibers and coalesce into larger droplets that drain by gravity to the bottom of the housing, where the automatic float drain expels them. Submicron solid particles are captured by depth filtration. The result is a continuous, energy-efficient way to deliver oil-free compressed air without the cost or complexity of an oil-free compressor.\u003c\/p\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grade\u003c\/td\u003e\n\u003ctd\u003eE — High-Efficiency Coalescing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e20 – 780 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Aerosol Removal\u003c\/td\u003e\n\u003ctd\u003e99.999% @ 0.01 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO 8573-1 Oil Class\u003c\/td\u003e\n\u003ctd\u003eClass 1 (≤ 0.01 mg\/m³)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISO 8573-1 Solids Class\u003c\/td\u003e\n\u003ctd\u003eClass 1 (0.1 micron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eAutomatic float drain (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003eBorosilicate microfiber, replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eCast aluminum, epoxy painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eInstall a Grade E wherever oil contamination would damage the product, process, or operator. Typical applications include automotive paint booths, custom finishing shops, powder coating, food and beverage packaging, dental operatories, orthodontic suites, medical and laboratory instrument air, pharmaceutical compounding, printing presses, and pneumatic conveying of food powders.\u003c\/p\u003e\u003ch2\u003eWhere to Install\u003c\/h2\u003e\u003cp\u003eA Grade E coalescing filter is installed \u003cem\u003edownstream\u003c\/em\u003e of your \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-dryers\"\u003eair dryer\u003c\/a\u003e. The recommended train is: compressor → aftercooler → \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-c-particulate-inline-filter\"\u003eCFL Grade C particulate pre-filter\u003c\/a\u003e → refrigerated or desiccant dryer → CFL Grade E coalescing filter → point of use. If your application requires Class 1 or Class 0 oil-vapor air (e.g. food-direct-contact), follow the Grade E with an activated-carbon Grade A filter as well.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually or whenever the differential-pressure indicator shows a 5–7 PSID rise across the filter, whichever comes first.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series filter ships with the full factory warranty, lifetime application support, and access to our certified compressed-air engineers for sizing and air-quality auditing.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDo I need both a Grade C and a Grade E filter?\u003c\/h3\u003e\u003cp\u003eFor best results, yes. A Grade C upstream protects the Grade E element from bulk solids and water, extending its life. The Grade E then polishes the air to ISO Class 1.\u003c\/p\u003e\u003ch3\u003eDoes the Grade E remove oil vapor?\u003c\/h3\u003e\u003cp\u003eIt removes oil aerosols and liquid oil down to 0.01 micron. Removing gaseous oil \u003cem\u003evapor\u003c\/em\u003e additionally requires an activated-carbon (Grade A) filter installed downstream of the Grade E.\u003c\/p\u003e\u003ch3\u003eHow do I choose the right size?\u003c\/h3\u003e\u003cp\u003eSize the filter to the actual SCFM flowing through that point in the system, not to compressor horsepower. When in doubt, size up — an oversized filter runs at lower pressure drop and lasts longer. Call our engineers if you need help.\u003c\/p\u003e\u003ch3\u003eHow often do I change the element?\u003c\/h3\u003e\u003cp\u003eReplace annually, or when differential pressure climbs 5–7 PSID above clean, whichever comes first.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"20 SCFM — 3\/8\" NPTF","offer_id":54604635242771,"sku":"CFL20E11APYTW","price":259.2,"currency_code":"USD","in_stock":true},{"title":"35 SCFM — 1\/2\" NPTF","offer_id":54604635275539,"sku":"CFL35E13APYTW","price":380.7,"currency_code":"USD","in_stock":true},{"title":"60 SCFM — 1\/2\" NPTF","offer_id":54604635308307,"sku":"CFL60E13APYTW","price":486.0,"currency_code":"USD","in_stock":true},{"title":"100 SCFM — 1\" NPTF","offer_id":54604635341075,"sku":"CFL100E17AGYTW","price":607.5,"currency_code":"USD","in_stock":true},{"title":"170 SCFM — 1\" NPTF","offer_id":54604635373843,"sku":"CFL170E17AGYTW","price":850.5,"currency_code":"USD","in_stock":true},{"title":"250 SCFM — 1-1\/2\" NPTF","offer_id":54604635406611,"sku":"CFL250E21AGYTW","price":1085.4,"currency_code":"USD","in_stock":true},{"title":"375 SCFM — 1-1\/2\" NPTF","offer_id":54604635439379,"sku":"CFL375E21AGYTW","price":1409.4,"currency_code":"USD","in_stock":true},{"title":"485 SCFM — 2\" NPTF","offer_id":54604635472147,"sku":"CFL485E23AGYTW","price":1725.3,"currency_code":"USD","in_stock":true},{"title":"625 SCFM — 2-1\/2\" NPTF","offer_id":54604635504915,"sku":"CFL625E25AGYTW","price":2033.1,"currency_code":"USD","in_stock":true},{"title":"780 SCFM — 2-1\/2\" NPTF","offer_id":54604635537683,"sku":"CFL780E25AGYTW","price":2365.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL1_36b8cba6-1157-4215-b847-88e6c385b4a8.png?v=1787575061"},{"product_id":"gfn-performance-validated-compressed-air-filter-by-nano","title":"GFN Performance Validated Compressed Air Filter By Nano","description":"\u003cp\u003eThe nano GFN performance validated \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filters\"\u003ecompressed air and gas filters\u003c\/a\u003e deliver clean, oil-free compressed air from a compact, energy-efficient die-cast aluminum housing. The range spans 18 housing sizes rated from 6 to 1500 SCFM at 100 psig with connections from 1\/8\" to 3\" NPT, and every grade is tested and validated in accordance with ISO 12500-1 and ISO 8573.1:2010, so the air quality you specify is the air quality you get. Deep-pleated borosilicate microfiber media captures particulate and coalesces oil aerosols with an extremely low pressure drop, cutting the energy cost of filtration, while internal and external E-Coat finishing protects the housing in demanding plant environments.\u003c\/p\u003e\n\n\u003ch3\u003eHow to select your GFN filter\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize by flow.\u003c\/strong\u003e Choose a housing whose rated flow at 100 psig meets or exceeds your system flow, from the 6 SCFM GFN 0006 up to the 1500 SCFM GFN 1500.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePick the filtration grade.\u003c\/strong\u003e M1 is the general-purpose first stage for 1 micron particulate and bulk oil removal. M01 installs after an M1 and polishes to 0.01 micron. AC installs after an M1 or M01 and adsorbs oil vapors and odors with activated carbon.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the connection.\u003c\/strong\u003e Each size uses a fixed NPT (F) port from 1\/8\" to 3\"; the port size is shown with each capacity option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStack stages for critical air.\u003c\/strong\u003e For technically oil-free air, run M1, then M01, then AC in series ahead of the point of use.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePerformance validated: tested to ISO 12500-1 and ISO 8573.1:2010 by design, not just claimed\u003c\/li\u003e\n\u003cli\u003eDeep-pleated media technology for exceptional coalescing and particulate retention with extremely low pressure drop\u003c\/li\u003e\n\u003cli\u003eDie-cast aluminum housing with powder-coated exterior and internal plus external E-Coat corrosion protection\u003c\/li\u003e\n\u003cli\u003eNo tie rod design for fast bowl removal and easy element changes\u003c\/li\u003e\n\u003cli\u003ePush-to-fit elements with color-coded end caps for quick grade identification\u003c\/li\u003e\n\u003cli\u003eAutomatic float drain standard on M1 and M01 grades; manual drain on AC grade\u003c\/li\u003e\n\u003cli\u003eDifferential pressure indication included on sizes GFN 0025 and larger\u003c\/li\u003e\n\u003cli\u003e10-year housing warranty from \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/nano-purification\"\u003enano-purification solutions\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated flow: 6 to 1500 SCFM at 100 psig (18 housing sizes)\u003c\/li\u003e\n\u003cli\u003eConnections: 1\/8\" to 3\" NPT (F)\u003c\/li\u003e\n\u003cli\u003eMaximum operating pressure: 232 psig\u003c\/li\u003e\n\u003cli\u003eOperating temperature: 32 to 176°F (M1 and M01), 32 to 122°F (AC)\u003c\/li\u003e\n\u003cli\u003eM1 grade: 1 micron particle removal, max oil carryover 0.3 ppm at 68°F\u003c\/li\u003e\n\u003cli\u003eM01 grade: 0.01 micron particle removal, max oil carryover 0.01 ppm at 68°F\u003c\/li\u003e\n\u003cli\u003eAC grade: activated carbon, max oil carryover 0.003 ppm at 68°F\u003c\/li\u003e\n\u003cli\u003eHousing: die-cast aluminum, E-Coat finished; elements: borosilicate microfiber with glass-filled nylon end caps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIdeal applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral plant compressed air ahead of refrigerated or \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/desiccant-air-dryers\"\u003edesiccant dryers\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003ePoint-of-use protection for air tools, instrumentation, and pneumatic controls\u003c\/li\u003e\n\u003cli\u003eFood and beverage, pharmaceutical, and medical air systems requiring validated air quality\u003c\/li\u003e\n\u003cli\u003ePaint spraying, powder coating, and laser cutting where oil and particulate cause rejects\u003c\/li\u003e\n\u003cli\u003eDirect upgrade or replacement for legacy filter housings, including Quincy-branded equivalents\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich grade do I need?\u003c\/strong\u003e\u003cbr\u003eStart with an M1 as the first stage. Add an M01 after it when you need 0.01 micron air, and an AC after the M01 when you need oil vapor and odor removal, such as breathing air pre-treatment or food contact air.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should elements be replaced?\u003c\/strong\u003e\u003cbr\u003enano recommends replacing M1 and M01 elements annually. AC elements should be replaced after every 1,000 hours of operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a drain included?\u003c\/strong\u003e\u003cbr\u003eYes. M1 and M01 filters ship with an automatic float drain; AC filters include a manual drain. External timed solenoid or zero air loss drains can be added.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum pressure?\u003c\/strong\u003e\u003cbr\u003eThe GFN range is rated to 232 psig. For higher pressures, see the nano G50N mid-pressure aluminum range rated to 725 psig.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre replacement elements available?\u003c\/strong\u003e\u003cbr\u003eYes. Each housing uses a push-to-fit GE series element in the matching grade, and we stock \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/coalescing-filters-elements\"\u003eGFN replacement elements\u003c\/a\u003e in M1, M01, and AC grades.\u003c\/p\u003e","brand":"Nano","offers":[{"title":"6 SCFM (1\/8\" NPT) \/ M1 (1 Micron)","offer_id":54620345893139,"sku":"8095170091","price":149.0,"currency_code":"USD","in_stock":true},{"title":"6 SCFM (1\/8\" NPT) \/ M01 (0.01 Micron)","offer_id":54620345925907,"sku":"8095170052","price":149.0,"currency_code":"USD","in_stock":true},{"title":"6 SCFM (1\/8\" NPT) \/ AC (Activated Carbon)","offer_id":54620345958675,"sku":"8095170013","price":149.0,"currency_code":"USD","in_stock":true},{"title":"15 SCFM (1\/4\" NPT) \/ M1 (1 Micron)","offer_id":54620345991443,"sku":"8095170092","price":156.0,"currency_code":"USD","in_stock":true},{"title":"15 SCFM (1\/4\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346024211,"sku":"8095170053","price":156.0,"currency_code":"USD","in_stock":true},{"title":"15 SCFM (1\/4\" NPT) \/ AC (Activated Carbon)","offer_id":54620346056979,"sku":"8095170014","price":156.0,"currency_code":"USD","in_stock":true},{"title":"25 SCFM (1\/4\" NPT) \/ M1 (1 Micron)","offer_id":54620346089747,"sku":"8095170093","price":216.0,"currency_code":"USD","in_stock":true},{"title":"25 SCFM (1\/4\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346122515,"sku":"8095170054","price":216.0,"currency_code":"USD","in_stock":true},{"title":"25 SCFM (1\/4\" NPT) \/ AC (Activated Carbon)","offer_id":54620346155283,"sku":"8095170015","price":216.0,"currency_code":"USD","in_stock":true},{"title":"32 SCFM (3\/8\" NPT) \/ M1 (1 Micron)","offer_id":54620346188051,"sku":"8095170094","price":227.0,"currency_code":"USD","in_stock":true},{"title":"32 SCFM (3\/8\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346220819,"sku":"8095170055","price":227.0,"currency_code":"USD","in_stock":true},{"title":"32 SCFM (3\/8\" NPT) \/ AC (Activated Carbon)","offer_id":54620346253587,"sku":"8095170016","price":227.0,"currency_code":"USD","in_stock":true},{"title":"50 SCFM (1\/2\" NPT) \/ M1 (1 Micron)","offer_id":54620346286355,"sku":"8095170095","price":286.0,"currency_code":"USD","in_stock":true},{"title":"50 SCFM (1\/2\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346319123,"sku":"8095170056","price":286.0,"currency_code":"USD","in_stock":true},{"title":"50 SCFM (1\/2\" NPT) \/ AC (Activated Carbon)","offer_id":54620346351891,"sku":"8095170017","price":286.0,"currency_code":"USD","in_stock":true},{"title":"70 SCFM (1\/2\" NPT) \/ M1 (1 Micron)","offer_id":54620346384659,"sku":"8095170096","price":336.0,"currency_code":"USD","in_stock":true},{"title":"70 SCFM (1\/2\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346417427,"sku":"8095170057","price":336.0,"currency_code":"USD","in_stock":true},{"title":"70 SCFM (1\/2\" NPT) \/ AC (Activated Carbon)","offer_id":54620346450195,"sku":"8095170018","price":336.0,"currency_code":"USD","in_stock":true},{"title":"85 SCFM (3\/4\" NPT) \/ M1 (1 Micron)","offer_id":54620346482963,"sku":"8095170097","price":370.0,"currency_code":"USD","in_stock":true},{"title":"85 SCFM (3\/4\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346515731,"sku":"8095170058","price":370.0,"currency_code":"USD","in_stock":true},{"title":"85 SCFM (3\/4\" NPT) \/ AC (Activated Carbon)","offer_id":54620346548499,"sku":"8095170019","price":370.0,"currency_code":"USD","in_stock":true},{"title":"105 SCFM (1\" NPT) \/ M1 (1 Micron)","offer_id":54620346581267,"sku":"8095170098","price":411.0,"currency_code":"USD","in_stock":true},{"title":"105 SCFM (1\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346614035,"sku":"8095170059","price":411.0,"currency_code":"USD","in_stock":true},{"title":"105 SCFM (1\" NPT) \/ AC (Activated Carbon)","offer_id":54620346646803,"sku":"8095170020","price":411.0,"currency_code":"USD","in_stock":true},{"title":"125 SCFM (3\/4\" NPT) \/ M1 (1 Micron)","offer_id":54620346679571,"sku":"8095170099","price":436.0,"currency_code":"USD","in_stock":true},{"title":"125 SCFM (3\/4\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346712339,"sku":"8095170060","price":436.0,"currency_code":"USD","in_stock":true},{"title":"125 SCFM (3\/4\" NPT) \/ AC (Activated Carbon)","offer_id":54620346745107,"sku":"8095170021","price":436.0,"currency_code":"USD","in_stock":true},{"title":"175 SCFM (1\" NPT) \/ M1 (1 Micron)","offer_id":54620346777875,"sku":"8095170100","price":510.0,"currency_code":"USD","in_stock":true},{"title":"175 SCFM (1\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346810643,"sku":"8095170061","price":510.0,"currency_code":"USD","in_stock":true},{"title":"175 SCFM (1\" NPT) \/ AC (Activated Carbon)","offer_id":54620346843411,"sku":"8095170022","price":510.0,"currency_code":"USD","in_stock":true},{"title":"280 SCFM (1-1\/4\" NPT) \/ M1 (1 Micron)","offer_id":54620346876179,"sku":"8095170101","price":689.0,"currency_code":"USD","in_stock":true},{"title":"280 SCFM (1-1\/4\" NPT) \/ M01 (0.01 Micron)","offer_id":54620346908947,"sku":"8095170062","price":689.0,"currency_code":"USD","in_stock":true},{"title":"280 SCFM (1-1\/4\" NPT) \/ AC (Activated Carbon)","offer_id":54620346941715,"sku":"8095170023","price":689.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (1-1\/2\" NPT) \/ M1 (1 Micron)","offer_id":54620346974483,"sku":"8095170102","price":807.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (1-1\/2\" NPT) \/ M01 (0.01 Micron)","offer_id":54620347007251,"sku":"8095170063","price":807.0,"currency_code":"USD","in_stock":true},{"title":"325 SCFM (1-1\/2\" NPT) \/ AC (Activated Carbon)","offer_id":54620347040019,"sku":"8095170024","price":807.0,"currency_code":"USD","in_stock":true},{"title":"450 SCFM (2\" NPT) \/ M1 (1 Micron)","offer_id":54620347072787,"sku":"8095170103","price":1055.0,"currency_code":"USD","in_stock":true},{"title":"450 SCFM (2\" NPT) \/ M01 (0.01 Micron)","offer_id":54620347105555,"sku":"8095170064","price":1055.0,"currency_code":"USD","in_stock":true},{"title":"450 SCFM (2\" NPT) \/ AC (Activated Carbon)","offer_id":54620347138323,"sku":"8095170025","price":1055.0,"currency_code":"USD","in_stock":true},{"title":"700 SCFM (2\" NPT) \/ M1 (1 Micron)","offer_id":54620347171091,"sku":"8095170329","price":1486.0,"currency_code":"USD","in_stock":true},{"title":"700 SCFM (2\" NPT) \/ M01 (0.01 Micron)","offer_id":54620347203859,"sku":"8095170314","price":1486.0,"currency_code":"USD","in_stock":true},{"title":"700 SCFM (2\" NPT) \/ AC (Activated Carbon)","offer_id":54620347236627,"sku":"8095170299","price":1486.0,"currency_code":"USD","in_stock":true},{"title":"850 SCFM (2-1\/2\" NPT) \/ M1 (1 Micron)","offer_id":54620347269395,"sku":"8095170330","price":1638.0,"currency_code":"USD","in_stock":true},{"title":"850 SCFM (2-1\/2\" NPT) \/ M01 (0.01 Micron)","offer_id":54620347302163,"sku":"8095170315","price":1638.0,"currency_code":"USD","in_stock":true},{"title":"850 SCFM (2-1\/2\" NPT) \/ AC (Activated Carbon)","offer_id":54620347334931,"sku":"8095170300","price":1638.0,"currency_code":"USD","in_stock":true},{"title":"900 SCFM (3\" NPT) \/ M1 (1 Micron)","offer_id":54620347367699,"sku":"8095170331","price":1669.0,"currency_code":"USD","in_stock":true},{"title":"900 SCFM (3\" NPT) \/ M01 (0.01 Micron)","offer_id":54620347400467,"sku":"8095170316","price":1669.0,"currency_code":"USD","in_stock":true},{"title":"900 SCFM (3\" NPT) \/ AC (Activated Carbon)","offer_id":54620347433235,"sku":"8095170301","price":1669.0,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPT) \/ M1 (1 Micron)","offer_id":54620347466003,"sku":"8095170332","price":1982.0,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPT) \/ M01 (0.01 Micron)","offer_id":54620347498771,"sku":"8095170317","price":1982.0,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPT) \/ AC (Activated Carbon)","offer_id":54620347531539,"sku":"8095170302","price":1982.0,"currency_code":"USD","in_stock":true},{"title":"1500 SCFM (3\" NPT) \/ M1 (1 Micron)","offer_id":54620347564307,"sku":"8095170333","price":2271.0,"currency_code":"USD","in_stock":true},{"title":"1500 SCFM (3\" NPT) \/ M01 (0.01 Micron)","offer_id":54620347597075,"sku":"8095170318","price":2271.0,"currency_code":"USD","in_stock":true},{"title":"1500 SCFM (3\" NPT) \/ AC (Activated Carbon)","offer_id":54620347629843,"sku":"8095170303","price":2271.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/gfn-performance-validated-compressed-air-filter-by-nano.png?v=1787835902"},{"product_id":"champion-cfl-series-grade-c-replacement-filter-element","title":"Champion CFL Series Replacement Filter Element – Grade C General Purpose Particulate (20–780 SCFM)","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion CFL Series Grade C replacement elements\u003c\/strong\u003e for the CFL general-purpose \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/particulate-removal-filters\"\u003eparticulate inline filter\u003c\/a\u003e line, in all ten sizes from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e. The housing is cast aluminum and stays in service for decades; the element is the wear part you replace.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your element by the flow rating of the housing it goes into.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhen to Replace\u003c\/h2\u003e\u003cp\u003eReplace the element \u003cstrong\u003eannually, or whenever differential pressure climbs 5 PSID above clean\u003c\/strong\u003e, whichever comes first. Running a clogged element wastes compressed-air energy at roughly 1% of compressor horsepower for every PSID of pressure drop, and a badly loaded element can rupture and dump collected debris downstream into the dryer or the tools it was installed to protect.\u003c\/p\u003e\u003ch2\u003eFits Both Indicator Styles\u003c\/h2\u003e\u003cp\u003eThe element is keyed to the housing size, not to the differential-pressure indicator. A CF100CE fits any 100 SCFM Grade C housing, whether the housing carries the \u003cstrong\u003eP\u003c\/strong\u003e differential-pressure slide (for example CFL100C17APTYW) or the \u003cstrong\u003eG\u003c\/strong\u003e differential-pressure gauge (CFL100C17AGYTW). The same holds at every size in the range, so a failed indicator never obsoletes your element stock.\u003c\/p\u003e\u003ch2\u003eElement Cross-Reference\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement P\/N\u003c\/th\u003e\n\u003cth\u003eHousing Flow\u003c\/th\u003e\n\u003cth\u003eFits Housing Models\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF20CE\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL20C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF35CE\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL35C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF60CE\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL60C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF100CE\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL100C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF170CE\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL170C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF250CE\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL250C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF375CE\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL375C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF485CE\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL485C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF625CE\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL625C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF780CE\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL780C series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eElement Performance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrade C — General Purpose Particulate\u003c\/strong\u003e, 1 micron at 1 ppm remaining oil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 8573-1 Class 2 solids\u003c\/strong\u003e — no particle larger than 1 micron passes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 8573-1 Class 4 oil\u003c\/strong\u003e — bulk oil and oil aerosol removal for general industrial service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePleated borosilicate fiber media\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG maximum working pressure\u003c\/strong\u003e, 150°F (66°C) maximum inlet temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eBuying Spares\u003c\/h2\u003e\u003cp\u003eMost plants stock two to six elements per housing so a change-out never waits on freight. If you run a Grade C ahead of a dryer and a \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E coalescing filter\u003c\/a\u003e downstream, keep spares for both; the Grade C loads first and protects the more expensive Grade E element behind it.\u003c\/p\u003e\u003ch2\u003eNeed the Complete Filter?\u003c\/h2\u003e\u003cp\u003eIf your housing itself is damaged rather than just loaded, the complete \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-c-particulate-inline-filter\"\u003eChampion CFL Series Grade C inline filter\u003c\/a\u003e is available in all ten sizes with automatic float drain and your choice of differential-pressure indicator.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/champion\"\u003eChampion Pneumatic\u003c\/a\u003e distributor. These are genuine Champion elements, not aftermarket equivalents, and they ship with full factory warranty and application support from our compressed-air engineers.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"CF20CE — 20 SCFM","offer_id":54698242474259,"sku":"CF20CE","price":59.13,"currency_code":"USD","in_stock":true},{"title":"CF35CE — 35 SCFM","offer_id":54698242507027,"sku":"CF35CE","price":70.47,"currency_code":"USD","in_stock":true},{"title":"CF60CE — 60 SCFM","offer_id":54698242539795,"sku":"CF60CE","price":102.87,"currency_code":"USD","in_stock":true},{"title":"CF100CE — 100 SCFM","offer_id":54698242572563,"sku":"CF100CE","price":127.17,"currency_code":"USD","in_stock":true},{"title":"CF170CE — 170 SCFM","offer_id":54698242605331,"sku":"CF170CE","price":166.05,"currency_code":"USD","in_stock":true},{"title":"CF250CE — 250 SCFM","offer_id":54698242638099,"sku":"CF250CE","price":183.06,"currency_code":"USD","in_stock":true},{"title":"CF375CE — 375 SCFM","offer_id":54698242670867,"sku":"CF375CE","price":235.71,"currency_code":"USD","in_stock":true},{"title":"CF485CE — 485 SCFM","offer_id":54698242703635,"sku":"CF485CE","price":244.62,"currency_code":"USD","in_stock":true},{"title":"CF625CE — 625 SCFM","offer_id":54698242736403,"sku":"CF625CE","price":255.15,"currency_code":"USD","in_stock":true},{"title":"CF780CE — 780 SCFM","offer_id":54698242769171,"sku":"CF780CE","price":295.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFLElement-GradesC_D_417f2897-f99c-43c7-b5e6-d7002d06921c.jpg?v=1789142188"},{"product_id":"champion-cfl-series-grade-e-replacement-filter-element","title":"Champion CFL Series Replacement Filter Element – Grade E High Efficiency Oil Removal (20–780 SCFM)","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion CFL Series Grade E replacement elements\u003c\/strong\u003e for the CFL high-efficiency \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/coalescing-filters-elements\"\u003ecoalescing oil-removal filter\u003c\/a\u003e line, in all ten sizes from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e. The cast aluminum housing stays in service for decades; the coalescing element is the wear part you replace.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your element by the flow rating of the housing it goes into.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhen to Replace\u003c\/h2\u003e\u003cp\u003eGrade E coalescing elements have a \u003cstrong\u003ehard 12-month service life regardless of differential pressure\u003c\/strong\u003e. Unlike a particulate element, a coalescer does not simply load up and show a pressure rise as it fails. The oil-wetted media degrades on a time basis, and a coalescer that looks fine on the DP gauge can already be passing oil aerosol downstream. Replace annually, or sooner if DP climbs 5 PSID above clean.\u003c\/p\u003e\u003ch2\u003eFits Both Indicator Styles\u003c\/h2\u003e\u003cp\u003eThe element is keyed to the housing size, not to the differential-pressure indicator. A CF100EE fits any 100 SCFM Grade E housing, whether the housing carries the \u003cstrong\u003eP\u003c\/strong\u003e differential-pressure slide or the \u003cstrong\u003eG\u003c\/strong\u003e differential-pressure gauge.\u003c\/p\u003e\u003ch2\u003eElement Cross-Reference\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement P\/N\u003c\/th\u003e\n\u003cth\u003eHousing Flow\u003c\/th\u003e\n\u003cth\u003eFits Housing Models\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF20EE\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL20E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF35EE\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL35E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF60EE\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL60E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF100EE\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL100E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF170EE\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL170E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF250EE\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL250E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF375EE\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL375E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF485EE\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL485E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF625EE\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL625E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF780EE\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL780E series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eElement Performance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrade E — High Efficiency Oil Removal\u003c\/strong\u003e, 0.01 micron at 0.008 ppm remaining oil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoalescing media\u003c\/strong\u003e with outside-to-inside drainage to the housing sump.\u003c\/li\u003e\n\u003cli\u003eRemoves \u003cstrong\u003eoil aerosols and submicron particles\u003c\/strong\u003e for instrument-quality air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG maximum working pressure\u003c\/strong\u003e, 150°F (66°C) maximum inlet temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eProtect the Coalescer\u003c\/h2\u003e\u003cp\u003eA Grade E element is the most expensive consumable in a typical treatment train, and it lasts far longer when a \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-c-replacement-filter-element\"\u003eGrade C particulate element\u003c\/a\u003e upstream catches the rust scale and pipe debris first. Running a coalescer as the first stage is the fastest way to waste one.\u003c\/p\u003e\u003ch2\u003eNeed the Complete Filter?\u003c\/h2\u003e\u003cp\u003eIf your housing itself is damaged rather than just loaded, the complete \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eChampion CFL Series Grade E coalescing filter\u003c\/a\u003e is available in all ten sizes.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/champion\"\u003eChampion Pneumatic\u003c\/a\u003e distributor. These are genuine Champion elements, not aftermarket equivalents, and they ship with full factory warranty and application support from our compressed-air engineers.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"CF20EE — 20 SCFM","offer_id":54698242834707,"sku":"CF20EE","price":68.85,"currency_code":"USD","in_stock":true},{"title":"CF35EE — 35 SCFM","offer_id":54698242867475,"sku":"CF35EE","price":86.67,"currency_code":"USD","in_stock":true},{"title":"CF60EE — 60 SCFM","offer_id":54698242900243,"sku":"CF60EE","price":117.45,"currency_code":"USD","in_stock":true},{"title":"CF100EE — 100 SCFM","offer_id":54698242933011,"sku":"CF100EE","price":168.48,"currency_code":"USD","in_stock":true},{"title":"CF170EE — 170 SCFM","offer_id":54698242965779,"sku":"CF170EE","price":217.89,"currency_code":"USD","in_stock":true},{"title":"CF250EE — 250 SCFM","offer_id":54698242998547,"sku":"CF250EE","price":243.81,"currency_code":"USD","in_stock":true},{"title":"CF375EE — 375 SCFM","offer_id":54698243031315,"sku":"CF375EE","price":353.97,"currency_code":"USD","in_stock":true},{"title":"CF485EE — 485 SCFM","offer_id":54698243064083,"sku":"CF485EE","price":390.42,"currency_code":"USD","in_stock":true},{"title":"CF625EE — 625 SCFM","offer_id":54698243096851,"sku":"CF625EE","price":420.39,"currency_code":"USD","in_stock":true},{"title":"CF780EE — 780 SCFM","offer_id":54698243129619,"sku":"CF780EE","price":545.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFLElement-GradesE_F_1ee14433-7eb2-4799-bfa2-72b6bdbed374.jpg?v=1789142188"},{"product_id":"champion-xc-series-compressed-air-filter","title":"Champion XC Series Compressed Air Filter - X-Series Inline Housing, Grades GP \/ HE \/ AC \/ DP (18-1,354 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion XC Series\u003c\/strong\u003e is Champion Pneumatic's X-Series inline compressed air filter line: sixteen housing sizes from \u003cstrong\u003e18 to 1,354 SCFM\u003c\/strong\u003e, each available in four filtration grades. A die-cast aluminum housing rated to \u003cstrong\u003e250 PSIG\u003c\/strong\u003e, a smooth-bore flow insert that directs air into the element and minimizes turbulence and pressure loss, and a dual indicator that reads both differential pressure and operating efficiency make the XC the filter Champion specifies on its own X-Series dryers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and filtration grade from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eFour Filtration Grades, One Housing Family\u003c\/h2\u003e\u003cp\u003eEvery XC housing of a given size shares the same body, connections and footprint. The grade determines the element inside, the ISO 8573-1 air quality you get out, and the drain that ships with it.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eWhat It Removes\u003c\/th\u003e\n\u003cth\u003eRating\u003c\/th\u003e\n\u003cth\u003eDrain\u003c\/th\u003e\n\u003cth\u003eWhere It Goes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eGP\u003c\/strong\u003e General Purpose\u003c\/td\u003e\n\u003ctd\u003eCoalesced liquid water and oil, solid particulate\u003c\/td\u003e\n\u003ctd\u003e1 micron, 0.1 ppm remaining oil aerosol @ 60°F\u003c\/td\u003e\n\u003ctd\u003eFloat drain, standard\u003c\/td\u003e\n\u003ctd\u003eCompressor discharge, dryer pre-filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eHE\u003c\/strong\u003e High Efficiency Oil Removal\u003c\/td\u003e\n\u003ctd\u003eOil aerosols, submicron particulate, water aerosol\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.01 ppm remaining oil aerosol @ 60°F\u003c\/td\u003e\n\u003ctd\u003eFloat drain, standard\u003c\/td\u003e\n\u003ctd\u003eDownstream of the dryer, instrument and paint air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAC\u003c\/strong\u003e Activated Carbon\u003c\/td\u003e\n\u003ctd\u003eOil vapor and hydrocarbon odor\u003c\/td\u003e\n\u003ctd\u003eLess than 0.003 ppm remaining oil @ 60°F\u003c\/td\u003e\n\u003ctd\u003eManual drain\u003c\/td\u003e\n\u003ctd\u003eFinal polish on odor-critical air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eDP\u003c\/strong\u003e Dust Filtration\u003c\/td\u003e\n\u003ctd\u003eDry dust and desiccant fines\u003c\/td\u003e\n\u003ctd\u003e1 micron solids\u003c\/td\u003e\n\u003ctd\u003eManual drain\u003c\/td\u003e\n\u003ctd\u003eAfter-filter on a desiccant dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eA correctly built train runs GP first, then the dryer, then HE, and AC last if the process cannot tolerate oil vapor. DP is the dust after-filter that protects the plant from desiccant carryover.\u003c\/p\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003cp\u003eDimensions are identical across all four grades. Connection is FNPT.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003ePipe Size\u003c\/th\u003e\n\u003cth\u003eDia. (A)\u003c\/th\u003e\n\u003cth\u003eHeight (B)\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC18\u003c\/td\u003e\n\u003ctd\u003e18 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e2.99\"\u003c\/td\u003e\n\u003ctd\u003e6.81\"\u003c\/td\u003e\n\u003ctd\u003e1.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC24\u003c\/td\u003e\n\u003ctd\u003e24 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e2.99\"\u003c\/td\u003e\n\u003ctd\u003e6.81\"\u003c\/td\u003e\n\u003ctd\u003e1.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC44\u003c\/td\u003e\n\u003ctd\u003e44 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e3.86\"\u003c\/td\u003e\n\u003ctd\u003e8.98\"\u003c\/td\u003e\n\u003ctd\u003e2.4 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC65\u003c\/td\u003e\n\u003ctd\u003e65 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e3.86\"\u003c\/td\u003e\n\u003ctd\u003e8.98\"\u003c\/td\u003e\n\u003ctd\u003e2.4 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC88\u003c\/td\u003e\n\u003ctd\u003e88 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e5.08\"\u003c\/td\u003e\n\u003ctd\u003e10.51\"\u003c\/td\u003e\n\u003ctd\u003e4.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC112\u003c\/td\u003e\n\u003ctd\u003e112 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e5.08\"\u003c\/td\u003e\n\u003ctd\u003e10.51\"\u003c\/td\u003e\n\u003ctd\u003e4.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC135\u003c\/td\u003e\n\u003ctd\u003e135 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e5.08\"\u003c\/td\u003e\n\u003ctd\u003e10.51\"\u003c\/td\u003e\n\u003ctd\u003e4.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC235\u003c\/td\u003e\n\u003ctd\u003e235 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\"\u003c\/td\u003e\n\u003ctd\u003e5.08\"\u003c\/td\u003e\n\u003ctd\u003e14.06\"\u003c\/td\u003e\n\u003ctd\u003e5.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC288\u003c\/td\u003e\n\u003ctd\u003e288 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\"\u003c\/td\u003e\n\u003ctd\u003e5.08\"\u003c\/td\u003e\n\u003ctd\u003e14.06\"\u003c\/td\u003e\n\u003ctd\u003e5.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC353\u003c\/td\u003e\n\u003ctd\u003e353 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003ctd\u003e6.69\"\u003c\/td\u003e\n\u003ctd\u003e18.35\"\u003c\/td\u003e\n\u003ctd\u003e11.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC471\u003c\/td\u003e\n\u003ctd\u003e471 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003ctd\u003e6.69\"\u003c\/td\u003e\n\u003ctd\u003e18.35\"\u003c\/td\u003e\n\u003ctd\u003e11.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC589\u003c\/td\u003e\n\u003ctd\u003e589 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\"\u003c\/td\u003e\n\u003ctd\u003e6.69\"\u003c\/td\u003e\n\u003ctd\u003e18.35\"\u003c\/td\u003e\n\u003ctd\u003e11.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC706\u003c\/td\u003e\n\u003ctd\u003e706 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e8.07\"\u003c\/td\u003e\n\u003ctd\u003e21.42\"\u003c\/td\u003e\n\u003ctd\u003e20.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC918\u003c\/td\u003e\n\u003ctd\u003e918 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e8.07\"\u003c\/td\u003e\n\u003ctd\u003e25.35\"\u003c\/td\u003e\n\u003ctd\u003e23.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC1077\u003c\/td\u003e\n\u003ctd\u003e1,077 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e8.07\"\u003c\/td\u003e\n\u003ctd\u003e25.35\"\u003c\/td\u003e\n\u003ctd\u003e23.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC1354\u003c\/td\u003e\n\u003ctd\u003e1,354 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e8.07\"\u003c\/td\u003e\n\u003ctd\u003e34.49\"\u003c\/td\u003e\n\u003ctd\u003e30.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eHow to Read an XC Part Number\u003c\/h2\u003e\u003cp\u003eThe part number is the grade, the flow rating, then the drain: \u003cstrong\u003eXC\u003c\/strong\u003e + \u003cstrong\u003eGP \/ HE \/ AC \/ DP\u003c\/strong\u003e + \u003cstrong\u003eflow in SCFM\u003c\/strong\u003e + \u003cstrong\u003eFD\u003c\/strong\u003e (float drain) or \u003cstrong\u003eM\u003c\/strong\u003e (manual drain). XCGP235FD is a 235 SCFM general purpose filter with a float drain. XCAC353M is a 353 SCFM activated carbon filter with a manual drain. Replacement elements drop the drain code and add \u003cstrong\u003eE\u003c\/strong\u003e, so XCGP235FD takes an \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xc-series-replacement-filter-element\"\u003eXCGP235E element\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e18 to 1,354 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Pressure\u003c\/td\u003e\n\u003ctd\u003e250 PSIG (17 bar g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Recommended Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e176°F (80°C) grades GP, HE and DP; 86°F (30°C) grade AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Recommended Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e34°F (1°C), all grades\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eDie-cast aluminum with smooth-bore flow insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicator\u003c\/td\u003e\n\u003ctd\u003eDual indicator: differential pressure and operating efficiency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eFloat drain standard on GP and HE; manual drain on AC and DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eFNPT, 3\/8\" through 3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003eField replaceable, grade specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhich XC Filter Ships With My Champion Dryer\u003c\/h2\u003e\u003cp\u003eChampion supplies XC filters ship-loose with its X-Series dryers. If you are replacing the filters that came with a dryer, this chart tells you which housing you have.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDryer\u003c\/th\u003e\n\u003cth\u003ePre-Filter\u003c\/th\u003e\n\u003cth\u003eAfter-Filter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xcnca-series-non-cycling-refrigerated-air-dryer\"\u003eXCNCA 75-100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eXCGP112FD\u003c\/td\u003e\n\u003ctd\u003eXCHE112FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCNCA 150-250\u003c\/td\u003e\n\u003ctd\u003eXCGP235FD\u003c\/td\u003e\n\u003ctd\u003eXCHE235FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCNCA 300 \/ 400\u003c\/td\u003e\n\u003ctd\u003eXCGP353FD \/ XCGP471FD\u003c\/td\u003e\n\u003ctd\u003eXCHE353FD \/ XCHE471FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCNCA 700 \/ 800-1000 \/ 1200\u003c\/td\u003e\n\u003ctd\u003eXCGP706FD \/ XCGP1077FD \/ XCGP1354FD\u003c\/td\u003e\n\u003ctd\u003eXCHE706FD \/ XCHE1077FD \/ XCHE1354FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xccya-series-cycling-refrigerated-air-dryer\"\u003eXCCYA 10-18 \/ 25-35 \/ 50\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eXCGP24FD \/ XCGP44FD \/ XCGP65FD\u003c\/td\u003e\n\u003ctd\u003eXCHE24FD \/ XCHE44FD \/ XCHE65FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCCYA 75-100 \/ 125 \/ 150-200 \/ 250\u003c\/td\u003e\n\u003ctd\u003eXCGP112FD \/ XCGP135FD \/ XCGP235FD \/ XCGP288FD\u003c\/td\u003e\n\u003ctd\u003eXCHE112FD \/ XCHE135FD \/ XCHE235FD \/ XCHE288FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xcmla-series-modular-desiccant-air-dryer\"\u003eXCMLA 3-15 \/ 24 \/ 32-41 \/ 59-88 \/ 118 \/ 147-177\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eXCHE18FD \/ XCHE24FD \/ XCHE44FD \/ XCHE88FD \/ XCHE135FD \/ XCHE235FD\u003c\/td\u003e\n\u003ctd\u003eXCGP18FD \/ XCGP24FD \/ XCGP44FD \/ XCGP88FD \/ XCGP135FD \/ XCGP235FD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eOn the heated desiccant machines, the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xchp-series-heated-purge-desiccant-air-dryer\"\u003eXCHP\u003c\/a\u003e and \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xchba-series-heated-blower-purge-desiccant-air-dryer\"\u003eXCHBA\u003c\/a\u003e, the mounted pre-filter elements are XCHE235E, XCHE288E, XCHE353E, XCHE589E, XCHE1077E and XCHE1354E by model size.\u003c\/p\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eRotary screw and reciprocating compressor discharge filtration, refrigerated and desiccant dryer protection, paint and powder coating feed lines, laser cutting assist gas, pneumatic instrumentation and control air, packaging machinery, laboratory air, plasma cutters, blow molding, and any plant where the cost of a contaminated production run exceeds the cost of an element. The AC grade is the right choice ahead of processes where hydrocarbon odor is a defect: food adjacent packaging, breathing air pre-treatment stages, and clean room support.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually, or when the dual indicator shows the differential pressure has climbed roughly 5 PSID above its clean condition, whichever comes first. A clogged element is not free: every PSID of unnecessary pressure drop costs about one half of one percent of the compressor's energy, and a saturated coalescing element will eventually re-entrain the oil it collected straight into your plant air. Activated carbon elements are the exception. They give no differential pressure warning because they adsorb vapor rather than trap particles, so they run on a strict calendar, typically every six to twelve months depending on inlet temperature.\u003c\/p\u003e\u003ch2\u003eModels Quoted on Request\u003c\/h2\u003e\u003cp\u003eThree configurations in this family are quoted rather than sold online: \u003cstrong\u003eXCGP589FD\u003c\/strong\u003e, \u003cstrong\u003eXCGP1077FD\u003c\/strong\u003e and \u003cstrong\u003eXCHE589FD\u003c\/strong\u003e. The current Champion price list prints a figure for each that is out of line with every neighboring size in the same table, so rather than publish a number we do not trust, we confirm those three with the factory before quoting. Call or email and we will have pricing back the same day. \u003cstrong\u003eXCAC706M\u003c\/strong\u003e and \u003cstrong\u003eXCDP1354M\u003c\/strong\u003e are listed at the published factory price, which is also higher than the pattern of their neighbors. If either of those is your size, call us before you order and let us check it.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Warthog Air Compressor Store\u003c\/h2\u003e\u003cp\u003eWarthog Air Compressor Store is an authorized Champion Pneumatic distributor. Every XC Series filter ships with the full factory warranty, and our compressed air engineers will size the train for you at no charge. Champion is part of Gardner Denver under Ingersoll Rand, and the XC Series is the Champion-branded equivalent of the Gardner Denver XG filter family, so XG cross-references interchange directly.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow do I size an XC filter?\u003c\/h3\u003e\u003cp\u003eSize to the actual SCFM passing that point in the piping, not to compressor horsepower, and not to the pipe size you happen to have. When you land between two sizes, go up. An oversized filter runs at a lower pressure drop, the element lasts longer, and the energy penalty disappears.\u003c\/p\u003e\u003ch3\u003eDo I need both a GP and an HE filter?\u003c\/h3\u003e\u003cp\u003eIf you have an oil-flooded rotary screw and any downstream process more sensitive than a sandblaster, yes. GP takes the bulk load so the HE element is not overwhelmed, and running HE alone means buying expensive coalescing elements far more often than you need to.\u003c\/p\u003e\u003ch3\u003eWhich grade goes after a desiccant dryer?\u003c\/h3\u003e\u003cp\u003eDP. Desiccant beds shed fines, and a 1 micron dust after-filter keeps that abrasive material out of your valves and tools. GP or HE downstream of a desiccant tower is the wrong tool and will load up quickly.\u003c\/p\u003e\u003ch3\u003eDoes the activated carbon grade remove water?\u003c\/h3\u003e\u003cp\u003eNo. AC removes oil vapor and hydrocarbon odor only. It must be installed downstream of a dryer and downstream of an HE coalescing filter, or liquid water will destroy the carbon bed in weeks.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the XC Series and the CFL Series?\u003c\/h3\u003e\u003cp\u003eBoth are Champion inline filters. The \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-c-particulate-inline-filter\"\u003eCFL Series\u003c\/a\u003e is the cast-aluminum modular and pressure-vessel line rated to 300 PSIG with slide or gauge indicators and several drain and indicator options. The XC Series is the X-Series line rated to 250 PSIG with a dual indicator standard, and it is what Champion mounts on and ships with its X-Series dryers. If you are matching an existing X-Series dryer, stay with XC.\u003c\/p\u003e\u003ch3\u003eCan I get a wall mounting kit or a different drain?\u003c\/h3\u003e\u003cp\u003eYes. Mounting hardware, electronic no-loss drains and BSP connections are available on request. Call us with the model number and we will quote the configured part.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"18 SCFM - 3\/8 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777749799187,"sku":"XCGP18FD","price":230.85,"currency_code":"USD","in_stock":true},{"title":"24 SCFM - 1\/2 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777749831955,"sku":"XCGP24FD","price":284.31,"currency_code":"USD","in_stock":true},{"title":"44 SCFM - 3\/4 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777749864723,"sku":"XCGP44FD","price":374.22,"currency_code":"USD","in_stock":true},{"title":"65 SCFM - 3\/4 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777749897491,"sku":"XCGP65FD","price":450.36,"currency_code":"USD","in_stock":true},{"title":"88 SCFM - 1 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777749930259,"sku":"XCGP88FD","price":495.72,"currency_code":"USD","in_stock":true},{"title":"112 SCFM - 1 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777749963027,"sku":"XCGP112FD","price":572.67,"currency_code":"USD","in_stock":true},{"title":"135 SCFM - 1 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777749995795,"sku":"XCGP135FD","price":609.93,"currency_code":"USD","in_stock":true},{"title":"235 SCFM - 1-1\/2 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777750028563,"sku":"XCGP235FD","price":942.84,"currency_code":"USD","in_stock":true},{"title":"288 SCFM - 1-1\/2 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777750061331,"sku":"XCGP288FD","price":1035.99,"currency_code":"USD","in_stock":true},{"title":"353 SCFM - 2 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777750094099,"sku":"XCGP353FD","price":1136.43,"currency_code":"USD","in_stock":true},{"title":"471 SCFM - 2 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777750126867,"sku":"XCGP471FD","price":1429.65,"currency_code":"USD","in_stock":true},{"title":"706 SCFM - 3 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777750159635,"sku":"XCGP706FD","price":2065.5,"currency_code":"USD","in_stock":true},{"title":"918 SCFM - 3 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777750192403,"sku":"XCGP918FD","price":2521.53,"currency_code":"USD","in_stock":true},{"title":"1354 SCFM - 3 in NPT \/ GP General Purpose 0.1 ppm (Float Drain)","offer_id":54777750225171,"sku":"XCGP1354FD","price":3521.07,"currency_code":"USD","in_stock":true},{"title":"18 SCFM - 3\/8 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750257939,"sku":"XCHE18FD","price":230.85,"currency_code":"USD","in_stock":true},{"title":"24 SCFM - 1\/2 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750290707,"sku":"XCHE24FD","price":294.03,"currency_code":"USD","in_stock":true},{"title":"44 SCFM - 3\/4 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750323475,"sku":"XCHE44FD","price":386.37,"currency_code":"USD","in_stock":true},{"title":"65 SCFM - 3\/4 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750356243,"sku":"XCHE65FD","price":480.33,"currency_code":"USD","in_stock":true},{"title":"88 SCFM - 1 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750389011,"sku":"XCHE88FD","price":510.3,"currency_code":"USD","in_stock":true},{"title":"112 SCFM - 1 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750421779,"sku":"XCHE112FD","price":588.87,"currency_code":"USD","in_stock":true},{"title":"135 SCFM - 1 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750454547,"sku":"XCHE135FD","price":609.93,"currency_code":"USD","in_stock":true},{"title":"235 SCFM - 1-1\/2 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750487315,"sku":"XCHE235FD","price":942.84,"currency_code":"USD","in_stock":true},{"title":"288 SCFM - 1-1\/2 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750520083,"sku":"XCHE288FD","price":1006.02,"currency_code":"USD","in_stock":true},{"title":"353 SCFM - 2 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750552851,"sku":"XCHE353FD","price":1102.41,"currency_code":"USD","in_stock":true},{"title":"471 SCFM - 2 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750585619,"sku":"XCHE471FD","price":1471.77,"currency_code":"USD","in_stock":true},{"title":"706 SCFM - 3 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750618387,"sku":"XCHE706FD","price":2065.5,"currency_code":"USD","in_stock":true},{"title":"918 SCFM - 3 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750651155,"sku":"XCHE918FD","price":2521.53,"currency_code":"USD","in_stock":true},{"title":"1077 SCFM - 3 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750683923,"sku":"XCHE1077FD","price":2986.47,"currency_code":"USD","in_stock":true},{"title":"1354 SCFM - 3 in NPT \/ HE High Efficiency Oil Removal 0.01 ppm (Float Drain)","offer_id":54777750716691,"sku":"XCHE1354FD","price":3521.07,"currency_code":"USD","in_stock":true},{"title":"18 SCFM - 3\/8 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777750749459,"sku":"XCAC18M","price":156.33,"currency_code":"USD","in_stock":true},{"title":"24 SCFM - 1\/2 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777750782227,"sku":"XCAC24M","price":183.06,"currency_code":"USD","in_stock":true},{"title":"44 SCFM - 3\/4 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777750814995,"sku":"XCAC44M","price":378.27,"currency_code":"USD","in_stock":true},{"title":"65 SCFM - 3\/4 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777750847763,"sku":"XCAC65M","price":440.64,"currency_code":"USD","in_stock":true},{"title":"88 SCFM - 1 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777750880531,"sku":"XCAC88M","price":499.77,"currency_code":"USD","in_stock":true},{"title":"112 SCFM - 1 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777750913299,"sku":"XCAC112M","price":561.33,"currency_code":"USD","in_stock":true},{"title":"135 SCFM - 1 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777750946067,"sku":"XCAC135M","price":597.78,"currency_code":"USD","in_stock":true},{"title":"235 SCFM - 1-1\/2 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777750978835,"sku":"XCAC235M","price":792.18,"currency_code":"USD","in_stock":true},{"title":"288 SCFM - 1-1\/2 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777751011603,"sku":"XCAC288M","price":985.77,"currency_code":"USD","in_stock":true},{"title":"353 SCFM - 2 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777751044371,"sku":"XCAC353M","price":1082.16,"currency_code":"USD","in_stock":true},{"title":"471 SCFM - 2 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777751077139,"sku":"XCAC471M","price":1443.42,"currency_code":"USD","in_stock":true},{"title":"589 SCFM - 2 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777751109907,"sku":"XCAC589M","price":1758.51,"currency_code":"USD","in_stock":true},{"title":"706 SCFM - 3 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777751142675,"sku":"XCAC706M","price":3794.04,"currency_code":"USD","in_stock":true},{"title":"918 SCFM - 3 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777751175443,"sku":"XCAC918M","price":2472.12,"currency_code":"USD","in_stock":true},{"title":"1077 SCFM - 3 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777751208211,"sku":"XCAC1077M","price":2844.72,"currency_code":"USD","in_stock":true},{"title":"1354 SCFM - 3 in NPT \/ AC Activated Carbon Oil Vapor (Manual Drain)","offer_id":54777751240979,"sku":"XCAC1354M","price":3558.33,"currency_code":"USD","in_stock":true},{"title":"18 SCFM - 3\/8 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751273747,"sku":"XCDP18M","price":230.85,"currency_code":"USD","in_stock":true},{"title":"24 SCFM - 1\/2 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751306515,"sku":"XCDP24M","price":284.31,"currency_code":"USD","in_stock":true},{"title":"44 SCFM - 3\/4 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751339283,"sku":"XCDP44M","price":374.22,"currency_code":"USD","in_stock":true},{"title":"65 SCFM - 3\/4 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751372051,"sku":"XCDP65M","price":450.36,"currency_code":"USD","in_stock":true},{"title":"88 SCFM - 1 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751404819,"sku":"XCDP88M","price":495.72,"currency_code":"USD","in_stock":true},{"title":"112 SCFM - 1 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751437587,"sku":"XCDP112M","price":553.23,"currency_code":"USD","in_stock":true},{"title":"135 SCFM - 1 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751470355,"sku":"XCDP135M","price":609.93,"currency_code":"USD","in_stock":true},{"title":"235 SCFM - 1-1\/2 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751503123,"sku":"XCDP235M","price":942.84,"currency_code":"USD","in_stock":true},{"title":"288 SCFM - 1-1\/2 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751535891,"sku":"XCDP288M","price":1006.02,"currency_code":"USD","in_stock":true},{"title":"353 SCFM - 2 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751568659,"sku":"XCDP353M","price":1102.41,"currency_code":"USD","in_stock":true},{"title":"471 SCFM - 2 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751601427,"sku":"XCDP471M","price":1471.77,"currency_code":"USD","in_stock":true},{"title":"589 SCFM - 2 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751634195,"sku":"XCDP589M","price":1793.34,"currency_code":"USD","in_stock":true},{"title":"706 SCFM - 3 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751666963,"sku":"XCDP706M","price":2065.5,"currency_code":"USD","in_stock":true},{"title":"918 SCFM - 3 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751699731,"sku":"XCDP918M","price":2521.53,"currency_code":"USD","in_stock":true},{"title":"1077 SCFM - 3 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751732499,"sku":"XCDP1077M","price":2900.61,"currency_code":"USD","in_stock":true},{"title":"1354 SCFM - 3 in NPT \/ DP Dust Filtration 1 Micron (Manual Drain)","offer_id":54777751765267,"sku":"XCDP1354M","price":11509.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/champion-xc-series-filter.jpg?v=1790075793"},{"product_id":"champion-xc-series-replacement-filter-element","title":"Champion XC Series Replacement Filter Element - Grades GP and HE (18-1,354 SCFM)","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion XC Series replacement filter elements\u003c\/strong\u003e for the X-Series inline filter housings, sized 18 through 1,354 SCFM. These are the factory elements, not an aftermarket equivalent, so the media grade, the end cap seal and the pressure drop curve all match what the housing and its dual indicator were designed around.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your housing size and element grade from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eFinding Your Element\u003c\/h2\u003e\u003cp\u003eThe element part number is the grade, the flow rating, then the letter E. An \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xc-series-compressed-air-filter\"\u003eXCGP235FD housing\u003c\/a\u003e takes an \u003cstrong\u003eXCGP235E\u003c\/strong\u003e element. An XCHE1077FD housing takes an \u003cstrong\u003eXCHE1077E\u003c\/strong\u003e. The drain code in the housing part number (FD for float drain, M for manual) has nothing to do with the element, so ignore it when you order.\u003c\/p\u003e\u003cp\u003eIf the housing label has faded, measure the housing body height and match it to the selection chart on the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xc-series-compressed-air-filter\"\u003eXC Series filter page\u003c\/a\u003e, or send us a photo of the nameplate and we will identify it.\u003c\/p\u003e\u003ch2\u003eElement Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eGrade GP Element\u003c\/th\u003e\n\u003cth\u003eGrade HE Element\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC18\u003c\/td\u003e\n\u003ctd\u003e18 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP18E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC24\u003c\/td\u003e\n\u003ctd\u003e24 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP24E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC44\u003c\/td\u003e\n\u003ctd\u003e44 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP44E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC65\u003c\/td\u003e\n\u003ctd\u003e65 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP65E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC88\u003c\/td\u003e\n\u003ctd\u003e88 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP88E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC112\u003c\/td\u003e\n\u003ctd\u003e112 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP112E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC135\u003c\/td\u003e\n\u003ctd\u003e135 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP135E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC235\u003c\/td\u003e\n\u003ctd\u003e235 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP235E\u003c\/td\u003e\n\u003ctd\u003eXCHE235E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC288\u003c\/td\u003e\n\u003ctd\u003e288 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP288E\u003c\/td\u003e\n\u003ctd\u003eXCHE288E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC353\u003c\/td\u003e\n\u003ctd\u003e353 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP353E\u003c\/td\u003e\n\u003ctd\u003eXCHE353E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC471\u003c\/td\u003e\n\u003ctd\u003e471 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP471E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC589\u003c\/td\u003e\n\u003ctd\u003e589 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP589E\u003c\/td\u003e\n\u003ctd\u003eXCHE589E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC706\u003c\/td\u003e\n\u003ctd\u003e706 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP706E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC918\u003c\/td\u003e\n\u003ctd\u003e918 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP918E\u003c\/td\u003e\n\u003ctd\u003eQuoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC1077\u003c\/td\u003e\n\u003ctd\u003e1,077 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP1077E\u003c\/td\u003e\n\u003ctd\u003eXCHE1077E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXC1354\u003c\/td\u003e\n\u003ctd\u003e1,354 SCFM\u003c\/td\u003e\n\u003ctd\u003eXCGP1354E\u003c\/td\u003e\n\u003ctd\u003eXCHE1354E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eThe Two Grades\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrade GP, General Purpose.\u003c\/strong\u003e Particle removal down to 1 micron including coalesced liquid, water and oil, leaving a maximum remaining oil aerosol content of 0.1 ppm at 60°F. This is the workhorse pre-filter element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrade HE, High Efficiency Oil Removal.\u003c\/strong\u003e Particle removal down to 0.01 micron including water and oil aerosols, leaving a maximum remaining oil aerosol content of 0.01 ppm at 60°F. This is the coalescing element that delivers instrument-quality air downstream of a dryer.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eGrade AC activated carbon and Grade DP dust elements are supplied for the matching housings but are not published on the current Champion element price list. Call us with the housing model and we will quote them from the factory.\u003c\/p\u003e\u003ch2\u003eWhen to Change the Element\u003c\/h2\u003e\u003cp\u003eChange the element annually, or when the housing's dual indicator shows differential pressure has risen roughly 5 PSID over its clean reading, whichever happens first. Two things go wrong when you stretch the interval. First, pressure drop costs money continuously: every PSID of avoidable restriction burns roughly half a percent of the compressor's power, every hour it runs. Second, a coalescing element that has been saturated past its capacity stops coalescing and starts re-entraining, so the oil it collected leaves in the air stream and lands in whatever is downstream.\u003c\/p\u003e\u003cp\u003eKeep one spare element per housing on the shelf. An element is cheap next to an unplanned shutdown, and these are not parts a local supply house stocks.\u003c\/p\u003e\u003ch2\u003eInstallation Notes\u003c\/h2\u003e\u003col\u003e\n\u003cli\u003eIsolate and fully depressurize the housing. Verify zero pressure at the drain before you touch the bowl.\u003c\/li\u003e\n\u003cli\u003eUnthread the bowl, remove the spent element, and wipe the sealing surfaces clean.\u003c\/li\u003e\n\u003cli\u003eInspect the bowl O-ring. Replace it if it is flattened, nicked or hardened.\u003c\/li\u003e\n\u003cli\u003eFit the new element hand tight. Do not lubricate the media end caps with anything other than clean compressed air system oil.\u003c\/li\u003e\n\u003cli\u003eRe-thread the bowl, repressurize slowly, and confirm the drain is functioning.\u003c\/li\u003e\n\u003cli\u003eNote the clean differential pressure reading so the next change interval has a baseline.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eWhy Buy from Warthog Air Compressor Store\u003c\/h2\u003e\u003cp\u003eWarthog Air Compressor Store is an authorized Champion Pneumatic distributor. These are genuine Champion elements from Gardner Denver under Ingersoll Rand, covered by the factory parts warranty, and our engineers will confirm the right part number before you order if you are unsure.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan I put an HE element in a GP housing?\u003c\/h3\u003e\u003cp\u003ePhysically, in the same size, yes, and people do it to upgrade filtration. Understand what you are buying: the HE element has a higher clean pressure drop and a shorter life when it is taking the bulk contaminant load that a GP element should have caught first. The right answer is usually two housings in series rather than one over-specified element.\u003c\/p\u003e\u003ch3\u003eAre aftermarket elements a problem?\u003c\/h3\u003e\u003cp\u003eThe risk is not the media, it is the seal and the collapse rating. An element that bypasses at the end cap filters nothing while reading a perfectly healthy pressure drop, and one that collapses sends its own media downstream. We sell the factory part.\u003c\/p\u003e\u003ch3\u003eDo these fit CFL Series housings?\u003c\/h3\u003e\u003cp\u003eNo. The \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-c-replacement-filter-element\"\u003eCFL Series uses its own CF-prefix elements\u003c\/a\u003e. XC elements fit XC housings only.\u003c\/p\u003e\u003ch3\u003eWhat weight will ship?\u003c\/h3\u003e\u003cp\u003eChampion does not publish element shipping weights in the current price list, so our cart estimates freight on the housing weight class. If you are booking your own freight or shipping internationally, call us and we will weigh the exact carton before it leaves.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"18 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752092947,"sku":"XCGP18E","price":75.33,"currency_code":"USD","in_stock":true},{"title":"24 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752125715,"sku":"XCGP24E","price":75.33,"currency_code":"USD","in_stock":true},{"title":"44 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752158483,"sku":"XCGP44E","price":85.86,"currency_code":"USD","in_stock":true},{"title":"65 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752191251,"sku":"XCGP65E","price":86.67,"currency_code":"USD","in_stock":true},{"title":"88 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752224019,"sku":"XCGP88E","price":104.49,"currency_code":"USD","in_stock":true},{"title":"112 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752256787,"sku":"XCGP112E","price":104.49,"currency_code":"USD","in_stock":true},{"title":"135 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752289555,"sku":"XCGP135E","price":109.35,"currency_code":"USD","in_stock":true},{"title":"235 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752322323,"sku":"XCGP235E","price":126.36,"currency_code":"USD","in_stock":true},{"title":"288 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752355091,"sku":"XCGP288E","price":126.36,"currency_code":"USD","in_stock":true},{"title":"353 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752387859,"sku":"XCGP353E","price":170.1,"currency_code":"USD","in_stock":true},{"title":"471 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752420627,"sku":"XCGP471E","price":178.2,"currency_code":"USD","in_stock":true},{"title":"589 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752453395,"sku":"XCGP589E","price":184.68,"currency_code":"USD","in_stock":true},{"title":"706 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752486163,"sku":"XCGP706E","price":214.65,"currency_code":"USD","in_stock":true},{"title":"918 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752518931,"sku":"XCGP918E","price":247.86,"currency_code":"USD","in_stock":true},{"title":"1077 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752551699,"sku":"XCGP1077E","price":247.86,"currency_code":"USD","in_stock":true},{"title":"1354 SCFM \/ GP General Purpose 1 Micron \/ 0.1 ppm","offer_id":54777752584467,"sku":"XCGP1354E","price":322.38,"currency_code":"USD","in_stock":true},{"title":"235 SCFM \/ HE High Efficiency Oil Removal 0.01 Micron \/ 0.01 ppm","offer_id":54777752617235,"sku":"XCHE235E","price":126.36,"currency_code":"USD","in_stock":true},{"title":"288 SCFM \/ HE High Efficiency Oil Removal 0.01 Micron \/ 0.01 ppm","offer_id":54777752650003,"sku":"XCHE288E","price":126.36,"currency_code":"USD","in_stock":true},{"title":"353 SCFM \/ HE High Efficiency Oil Removal 0.01 Micron \/ 0.01 ppm","offer_id":54777752682771,"sku":"XCHE353E","price":170.1,"currency_code":"USD","in_stock":true},{"title":"589 SCFM \/ HE High Efficiency Oil Removal 0.01 Micron \/ 0.01 ppm","offer_id":54777752715539,"sku":"XCHE589E","price":184.68,"currency_code":"USD","in_stock":true},{"title":"1077 SCFM \/ HE High Efficiency Oil Removal 0.01 Micron \/ 0.01 ppm","offer_id":54777752748307,"sku":"XCHE1077E","price":247.05,"currency_code":"USD","in_stock":true},{"title":"1354 SCFM \/ HE High Efficiency Oil Removal 0.01 Micron \/ 0.01 ppm","offer_id":54777752781075,"sku":"XCHE1354E","price":321.57,"currency_code":"USD","in_stock":true}]},{"product_id":"champion-cfl-series-grade-a-mechanical-water-separator","title":"Champion CFL Series Inline Moisture Separator – Grade A Mechanical Water Separator (20–780 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series Grade A\u003c\/strong\u003e is a \u003cstrong\u003emechanical (centrifugal) moisture separator\u003c\/strong\u003e available in ten flow rates from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e. It uses a high-velocity swirl chamber rather than a filter media to fling bulk liquid water, condensate slugs, and coarse pipe scale out of the air stream, then drains them away automatically. Rated to \u003cstrong\u003e300 PSIG\u003c\/strong\u003e, the Grade A is the very first stage of a properly designed compressed-air treatment train and the cheapest insurance you can buy for the dryer and filters behind it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and connection size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhy a Mechanical Separator Comes First\u003c\/h2\u003e\u003cp\u003eA compressor aftercooler knocks the air temperature down fast, and most of the water vapor the compressor swallowed condenses right there into liquid. That liquid arrives downstream as slugs and mist. Sending it straight into a coalescing filter floods the element, collapses filter life to a matter of weeks, and drives pressure drop through the roof. A \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filters\"\u003emechanical separator\u003c\/a\u003e strips that bulk liquid out with almost no pressure loss and no consumable media, so the \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/coalescing-air-filters\"\u003ecoalescing filters\u003c\/a\u003e behind it only have to deal with aerosols and the \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/refrigerated-air-dryers\"\u003erefrigerated dryer\u003c\/a\u003e only has to deal with vapor.\u003c\/p\u003e\u003ch2\u003eSeparation Performance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulk Liquid Removal\u003c\/strong\u003e — Up to 99% of free liquid water and oil carried in the air stream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanism\u003c\/strong\u003e — Centrifugal swirl separation, no filter media to load up or replace on a schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Drop\u003c\/strong\u003e — Very low and, unlike a media filter, essentially constant over the life of the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eDimensions (H x W)\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL20A11AYTW\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8 x 4 in\u003c\/td\u003e\n\u003ctd\u003e4.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF20AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL35A13AYTW\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e11 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.1 lb\u003c\/td\u003e\n\u003ctd\u003eCF35AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL60A13AYTW\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e13 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.5 lb\u003c\/td\u003e\n\u003ctd\u003eCF60AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL100A17AYTW\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e15 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF100AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL170A17AYTW\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e20 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.9 lb\u003c\/td\u003e\n\u003ctd\u003eCF170AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL250A21YTW\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e23 x 6 in\u003c\/td\u003e\n\u003ctd\u003e10.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF250AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL375A21YTW\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e27 x 6 in\u003c\/td\u003e\n\u003ctd\u003e11.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF375AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL485A23YTW\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e31 x 8 in\u003c\/td\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003ctd\u003eCF485AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625A25YTW\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e37 x 8 in\u003c\/td\u003e\n\u003ctd\u003e33 lb\u003c\/td\u003e\n\u003ctd\u003eCF625AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL780A25YTW\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e43 x 8 in\u003c\/td\u003e\n\u003ctd\u003e38 lb\u003c\/td\u003e\n\u003ctd\u003eCF780AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eModels 20 through 170 ship with an internal automatic float drain. Models 250 through 780 ship with a manual drain as standard; an internal automatic drain or an electronic demand drain can be substituted at order entry. Connection sizes other than those listed, including BSP threads, are available on the same housings. Call us and we will configure the part number for you.\u003c\/p\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Separation\u003c\/strong\u003e — Removes up to 99% of bulk liquid with no media to blind off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 to 780 SCFM Rated Flow\u003c\/strong\u003e — Ten sizes covering a 5 HP shop compressor through large plant air headers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e — 250 PSIG when supplied with the internal automatic drain or liquid level indicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e — Handles hot discharge air directly off the aftercooler.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Cast Aluminum Housing\u003c\/strong\u003e — Corrosion resistant, factory pressure tested.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Float Drain\u003c\/strong\u003e — Standard on models 20 through 170, optional on the larger sizes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Body\u003c\/strong\u003e — Bolts directly to other CFL housings with a connector kit, so a separator plus filter stack takes almost no extra pipe length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChampion Pneumatic Quality\u003c\/strong\u003e — Backed by over a century of compressed-air engineering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grade\u003c\/td\u003e\n\u003ctd\u003eA — Mechanical (Centrifugal) Separator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e20 – 780 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG with manual drain, 250 PSIG with automatic drain or liquid level indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulk Liquid Removal\u003c\/td\u003e\n\u003ctd\u003eUp to 99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eAutomatic float drain (models 20-170), manual drain (models 250-780)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003eStainless steel separator element, field replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eCast aluminum, epoxy painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Point\u003c\/td\u003e\n\u003ctd\u003eF.O.B. Ocala, FL 34474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eInstall a Grade A immediately downstream of the aftercooler or wet receiver on any system that makes visible water: reciprocating compressors in humid climates, rotary screw packages without an integral separator, outdoor or unheated compressor rooms, plants with long uninsulated header runs, and any system where the coalescing filters are loading up far faster than they should. It is also the standard pre-treatment ahead of a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/desiccant-air-dryers\"\u003edesiccant dryer\u003c\/a\u003e, where liquid water carryover will destroy a desiccant bed outright.\u003c\/p\u003e\u003ch2\u003eBuild Your Filtration Train\u003c\/h2\u003e\u003cp\u003eFor a complete compressed-air treatment system, install in this order: (1) \u003cstrong\u003eCFL Grade A mechanical separator\u003c\/strong\u003e to knock out bulk liquid; (2) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-c-particulate-inline-filter\"\u003eCFL Grade C particulate filter\u003c\/a\u003e to remove solids; (3) refrigerated or desiccant \u003cstrong\u003edryer\u003c\/strong\u003e to remove water vapor; (4) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eCFL Grade E coalescing filter\u003c\/a\u003e for instrument-quality air.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eThe Grade A separator element is a stainless steel swirl element rather than a consumable media cartridge, so it does not need an annual change the way a coalescing element does. Inspect it at each scheduled shutdown, clean it if it has collected scale, and replace it if it is damaged or corroded. The part you need is the \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filter-elements\"\u003eCF-series element\u003c\/a\u003e matching your housing size, listed in the chart above. What does need attention is the drain: verify it is discharging and not stuck open, because a stuck drain either floods the housing or bleeds compressed air continuously.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series separator ships with the full factory warranty, lifetime application support, and access to our compressed-air engineers for sizing and system design. Need a configuration that is not in the dropdown, such as BSP threads, an electronic demand drain, or a liquid level indicator? Call us and we will build the part number.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between a Grade A separator and a Grade C filter?\u003c\/h3\u003e\u003cp\u003eA Grade A uses centrifugal force to throw bulk liquid out of the air stream. A Grade C uses a media element to trap solid particles down to 1 micron. They do different jobs and in a well-designed system you use both, with the separator first.\u003c\/p\u003e\u003ch3\u003eDo I still need a dryer if I install a separator?\u003c\/h3\u003e\u003cp\u003eYes. A separator removes liquid water that has already condensed. It cannot remove water vapor, which will condense later as the air cools in the piping. A separator protects the dryer; it does not replace it.\u003c\/p\u003e\u003ch3\u003eHow do I size one?\u003c\/h3\u003e\u003cp\u003eSize to the actual SCFM flowing through that point in the system, not to compressor horsepower. Undersizing a separator hurts twice, because separation efficiency falls off at high velocity and pressure drop climbs. When in doubt, size up.\u003c\/p\u003e\u003ch3\u003eCan I mount this to other CFL filters?\u003c\/h3\u003e\u003cp\u003eYes. Housings 20 through 170 join with modular connector kit C23428001 or C23428002, and housings 250 through 780 join with manifold kit C23436001 or C23436002, so a separator and filter share one compact assembly.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"20 SCFM — 3\/8\" NPTF","offer_id":54781541122323,"sku":"CFL20A11AYTW","price":307.8,"currency_code":"USD","in_stock":true},{"title":"35 SCFM — 1\/2\" NPTF","offer_id":54781541155091,"sku":"CFL35A13AYTW","price":332.1,"currency_code":"USD","in_stock":true},{"title":"60 SCFM — 1\/2\" NPTF","offer_id":54781541187859,"sku":"CFL60A13AYTW","price":429.3,"currency_code":"USD","in_stock":true},{"title":"100 SCFM — 1\" NPTF","offer_id":54781541220627,"sku":"CFL100A17AYTW","price":461.7,"currency_code":"USD","in_stock":true},{"title":"170 SCFM — 1\" NPTF","offer_id":54781541253395,"sku":"CFL170A17AYTW","price":696.6,"currency_code":"USD","in_stock":true},{"title":"250 SCFM — 1-1\/2\" NPTF","offer_id":54781541286163,"sku":"CFL250A21YTW","price":874.8,"currency_code":"USD","in_stock":true},{"title":"375 SCFM — 1-1\/2\" NPTF","offer_id":54781541318931,"sku":"CFL375A21YTW","price":1182.6,"currency_code":"USD","in_stock":true},{"title":"485 SCFM — 2\" NPTF","offer_id":54781541351699,"sku":"CFL485A23YTW","price":1498.5,"currency_code":"USD","in_stock":true},{"title":"625 SCFM — 2-1\/2\" NPTF","offer_id":54781541384467,"sku":"CFL625A25YTW","price":1757.7,"currency_code":"USD","in_stock":true},{"title":"780 SCFM — 2-1\/2\" NPTF","offer_id":54781541417235,"sku":"CFL780A25YTW","price":2049.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL1.png?v=1780354005"},{"product_id":"champion-cfl-series-grade-b-general-purpose-separator-filter","title":"Champion CFL Series Inline Air Filter – Grade B General Purpose Separator\/Filter, 3 Micron (20–780 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series Grade B\u003c\/strong\u003e is a \u003cstrong\u003ecombination separator and general purpose filter\u003c\/strong\u003e available in ten flow rates from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e. A single Grade B housing does two jobs at once: it separates bulk liquid out of the air stream and then filters what is left down to \u003cstrong\u003e3 micron with a residual oil carryover of 5 ppm\u003c\/strong\u003e. Rated to \u003cstrong\u003e300 PSIG\u003c\/strong\u003e, it is the one-filter answer for shops that want real protection on a general-purpose air system without stacking two separate housings.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and connection size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eTwo Stages in One Housing\u003c\/h2\u003e\u003cp\u003eAir entering a Grade B first hits a separation section that throws out condensate slugs and heavy droplets, then passes through a pleated depth element that captures solid particles and coalesces the remaining oil aerosol. That two-stage arrangement is why the Grade B lasts so much longer than a bare coalescing element installed on wet air, and why it is the standard choice ahead of pneumatic tools, cylinders, and \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/regulators\"\u003eregulators\u003c\/a\u003e in general plant service. Where you need instrument-quality air, follow it with a \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E high-efficiency coalescing filter\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eISO 8573-1:2010 Air Quality Performance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eParticle Removal\u003c\/strong\u003e — 3 micron, covering the solids that damage tool vanes, seals, and orifices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemaining Oil Content\u003c\/strong\u003e — 5 ppm by weight, suitable for general industrial and shop air service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Removal\u003c\/strong\u003e — Integral separation section removes bulk condensate before it reaches the element.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eDimensions (H x W)\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL20B11APYTW\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8 x 4 in\u003c\/td\u003e\n\u003ctd\u003e4.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF20BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL35B13APYTW\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e11 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.1 lb\u003c\/td\u003e\n\u003ctd\u003eCF35BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL60B13APYTW\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e13 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.5 lb\u003c\/td\u003e\n\u003ctd\u003eCF60BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL100B17AGYTW\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e15 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF100BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL170B17AGYTW\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e20 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.9 lb\u003c\/td\u003e\n\u003ctd\u003eCF170BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL250B21GYTW\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e23 x 6 in\u003c\/td\u003e\n\u003ctd\u003e10.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF250BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL375B21GYTW\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e27 x 6 in\u003c\/td\u003e\n\u003ctd\u003e11.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF375BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL485B23GYTW\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e31 x 8 in\u003c\/td\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003ctd\u003eCF485BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625B25GYTW\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e37 x 8 in\u003c\/td\u003e\n\u003ctd\u003e33 lb\u003c\/td\u003e\n\u003ctd\u003eCF625BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL780B25GYTW\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e43 x 8 in\u003c\/td\u003e\n\u003ctd\u003e38 lb\u003c\/td\u003e\n\u003ctd\u003eCF780BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eModels 20 through 60 ship with an internal automatic drain and a differential pressure slide indicator. Models 100 and 170 ship with an internal automatic drain and a differential pressure gauge. Models 250 through 780 ship with a gauge and a manual or plugged drain port; an internal automatic drain or an electronic demand drain can be substituted at order entry. BSP threads, alternate connection sizes, a liquid level indicator, and a 304 stainless element are all available. Call us and we will configure the part number.\u003c\/p\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparator Plus Filter in One Housing\u003c\/strong\u003e — Bulk liquid separation and 3 micron filtration without two pieces of pipe work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 Micron \/ 5 PPM Performance\u003c\/strong\u003e — The right specification for general plant air, tools, and cylinders.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 to 780 SCFM Rated Flow\u003c\/strong\u003e — Ten sizes from a small shop compressor to a large plant header.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e — 250 PSIG when supplied with the internal automatic drain or liquid level indicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e — Takes hot air straight off the aftercooler.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Indicator\u003c\/strong\u003e — Slide or gauge, so element changes happen when they are needed rather than on a guess.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Cast Aluminum Housing\u003c\/strong\u003e — Corrosion resistant and factory pressure tested.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-Replaceable Element\u003c\/strong\u003e — The housing stays in service for decades; only the cartridge is consumable.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grade\u003c\/td\u003e\n\u003ctd\u003eB — Separator \/ General Purpose Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticle Removal\u003c\/td\u003e\n\u003ctd\u003e3 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemaining Oil Content\u003c\/td\u003e\n\u003ctd\u003e5 ppm w\/w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e20 – 780 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG with manual drain, 250 PSIG with automatic drain or liquid level indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003ePleated media with 409 stainless core, 304 stainless optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eCast aluminum, epoxy painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Point\u003c\/td\u003e\n\u003ctd\u003eF.O.B. Ocala, FL 34474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eThe Grade B suits general industrial plant air, pneumatic tool and cylinder supply, automotive service bays, woodworking and fabrication shops, packaging lines, and any point-of-use drop where a single filter has to handle both liquid and particulate. It is a strong pre-filter ahead of a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/refrigerated-air-dryers\"\u003erefrigerated dryer\u003c\/a\u003e on systems that run wet, because the separation section keeps condensate out of the dryer heat exchanger.\u003c\/p\u003e\u003ch2\u003eBuild Your Filtration Train\u003c\/h2\u003e\u003cp\u003eFor a complete compressed-air treatment system: (1) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-a-mechanical-water-separator\"\u003eCFL Grade A mechanical separator\u003c\/a\u003e or a Grade B at the compressor discharge; (2) refrigerated or desiccant \u003cstrong\u003edryer\u003c\/strong\u003e; (3) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eCFL Grade E coalescing filter\u003c\/a\u003e downstream of the dryer; (4) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-g-oil-vapor-removal-carbon-filter\"\u003eCFL Grade G carbon filter\u003c\/a\u003e where oil vapor and odor must go too.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually, or whenever the differential pressure indicator shows a 5 PSID rise across the filter, whichever comes first. Running a clogged element wastes energy at roughly 1% of compressor horsepower per PSID of pressure drop and eventually risks element rupture. \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-b-replacement-filter-element\"\u003eGenuine Champion CF-series Grade B elements\u003c\/a\u003e are listed in the chart above.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series filter ships with the full factory warranty, lifetime application support, and access to our compressed-air engineers for sizing and system design.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow is a Grade B different from a Grade C?\u003c\/h3\u003e\u003cp\u003eA Grade C is a 1 micron particulate filter. A Grade B is a combination separator and filter rated at 3 micron and 5 ppm oil, so it removes bulk liquid as well as solids. Choose Grade B where the air is wet and general-purpose quality is enough; choose Grade C where the air is already dry and you want a finer particle rating.\u003c\/p\u003e\u003ch3\u003eIs a Grade B good enough for paint spraying?\u003c\/h3\u003e\u003cp\u003eNo. For paint, follow the Grade B with a \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E coalescing filter\u003c\/a\u003e, and add a \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-g-oil-vapor-removal-carbon-filter\"\u003eGrade G carbon filter\u003c\/a\u003e if you are getting fisheyes from oil vapor.\u003c\/p\u003e\u003ch3\u003eHow do I choose the right size?\u003c\/h3\u003e\u003cp\u003eSize to the actual SCFM flowing through that point in the system, not to compressor horsepower. An oversized housing runs at lower pressure drop and the element lasts longer, so when in doubt, size up.\u003c\/p\u003e\u003ch3\u003eSlide indicator or gauge?\u003c\/h3\u003e\u003cp\u003eThe slide is a simple pop-up visual telling you the element is loaded. The gauge reads the actual differential in PSID and is easier to trend over time. Either can be specified on any size; the gauge is a $120 list adder in place of the slide.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"20 SCFM — 3\/8\" NPTF","offer_id":54781541712147,"sku":"CFL20B11APYTW","price":364.5,"currency_code":"USD","in_stock":true},{"title":"35 SCFM — 1\/2\" NPTF","offer_id":54781541744915,"sku":"CFL35B13APYTW","price":388.8,"currency_code":"USD","in_stock":true},{"title":"60 SCFM — 1\/2\" NPTF","offer_id":54781541777683,"sku":"CFL60B13APYTW","price":510.3,"currency_code":"USD","in_stock":true},{"title":"100 SCFM — 1\" NPTF","offer_id":54781541810451,"sku":"CFL100B17AGYTW","price":599.4,"currency_code":"USD","in_stock":true},{"title":"170 SCFM — 1\" NPTF","offer_id":54781541843219,"sku":"CFL170B17AGYTW","price":850.5,"currency_code":"USD","in_stock":true},{"title":"250 SCFM — 1-1\/2\" NPTF","offer_id":54781541875987,"sku":"CFL250B21GYTW","price":1069.2,"currency_code":"USD","in_stock":true},{"title":"375 SCFM — 1-1\/2\" NPTF","offer_id":54781541908755,"sku":"CFL375B21GYTW","price":1401.3,"currency_code":"USD","in_stock":true},{"title":"485 SCFM — 2\" NPTF","offer_id":54781541941523,"sku":"CFL485B23GYTW","price":1757.7,"currency_code":"USD","in_stock":true},{"title":"625 SCFM — 2-1\/2\" NPTF","offer_id":54781541974291,"sku":"CFL625B25GYTW","price":2049.3,"currency_code":"USD","in_stock":true},{"title":"780 SCFM — 2-1\/2\" NPTF","offer_id":54781542007059,"sku":"CFL780B25GYTW","price":2332.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL1.png?v=1780354005"},{"product_id":"champion-cfl-series-grade-d-dry-particulate-afterfilter","title":"Champion CFL Series Inline Air Filter – Grade D Dry Particulate Desiccant Afterfilter (20–780 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series Grade D\u003c\/strong\u003e is a \u003cstrong\u003edry particulate afterfilter\u003c\/strong\u003e built specifically for the outlet of a desiccant dryer, available in ten flow rates from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e. It captures desiccant fines down to \u003cstrong\u003e1 micron\u003c\/strong\u003e before they get into the plant header. Unlike the coalescing grades, the Grade D element flows \u003cstrong\u003eoutside to inside\u003c\/strong\u003e, which is the correct direction for catching dry dust rather than draining liquid, and it is the reason a Grade D lasts in this service where a general purpose filter plugs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and connection size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhy a Desiccant Dryer Needs an Afterfilter\u003c\/h2\u003e\u003cp\u003eEvery desiccant bed abrades. Activated alumina and molecular sieve beads grind against each other on every pressurization and depressurization cycle of a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/desiccant-air-dryers\"\u003eheatless or heated regenerative dryer\u003c\/a\u003e, and the resulting dust leaves with the air. That dust is hard, abrasive, and small enough to pass straight through a coarse filter. Downstream it scores valve seats, packs into orifices and nozzles, contaminates product in food and pharmaceutical lines, and shows up as grit in finished paint. An afterfilter at the dryer outlet is not optional equipment on a desiccant system; it is part of the dryer.\u003c\/p\u003e\u003ch2\u003ePerformance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eParticle Removal\u003c\/strong\u003e — 1 micron, sized for desiccant fines and dry pipe scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Direction\u003c\/strong\u003e — Outside to inside, so dust loads on the outer surface where the media has the most area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry Service\u003c\/strong\u003e — No drain needed; the air leaving a desiccant dryer is already at a very low dew point.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eDimensions (H x W)\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL20D11PYTW\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8 x 4 in\u003c\/td\u003e\n\u003ctd\u003e4.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF20DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL35D13PYTW\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e11 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.1 lb\u003c\/td\u003e\n\u003ctd\u003eCF35DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL60D13PYTW\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e13 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.5 lb\u003c\/td\u003e\n\u003ctd\u003eCF60DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL100D17GYTW\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e15 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF100DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL170D17GYTW\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e20 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.9 lb\u003c\/td\u003e\n\u003ctd\u003eCF170DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL250D21GYTW\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e23 x 6 in\u003c\/td\u003e\n\u003ctd\u003e10.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF250DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL375D21GYTW\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e27 x 6 in\u003c\/td\u003e\n\u003ctd\u003e11.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF375DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL485D23GYTW\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e31 x 8 in\u003c\/td\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003ctd\u003eCF485DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625D25GYTW\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e37 x 8 in\u003c\/td\u003e\n\u003ctd\u003e33 lb\u003c\/td\u003e\n\u003ctd\u003eCF625DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL780D25GYTW\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e43 x 8 in\u003c\/td\u003e\n\u003ctd\u003e38 lb\u003c\/td\u003e\n\u003ctd\u003eCF780DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eModels 20 through 60 ship with a differential pressure slide indicator; models 100 through 780 ship with a differential pressure gauge. Because this is dry service, no drain is fitted as standard. Alternate connection sizes, BSP threads, and a slide in place of the gauge are available. Call us and we will configure the part number.\u003c\/p\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Micron Dry Particulate Removal\u003c\/strong\u003e — Stops desiccant dust at the dryer outlet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside-to-Inside Flow Path\u003c\/strong\u003e — Purpose-built for dust loading, not liquid drainage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 to 780 SCFM Rated Flow\u003c\/strong\u003e — Matched to the full Champion desiccant dryer range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e — Ample margin on any standard plant air system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e — Handles the warm outlet air of a heated or blower purge dryer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Indicator\u003c\/strong\u003e — Slide or gauge, so you change the element on data rather than on a calendar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Cast Aluminum Housing\u003c\/strong\u003e — Corrosion resistant, factory pressure tested.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Body\u003c\/strong\u003e — Bolts to other CFL housings with a connector kit for a compact stack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grade\u003c\/td\u003e\n\u003ctd\u003eD — Dry Particulate Afterfilter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticle Removal\u003c\/td\u003e\n\u003ctd\u003e1 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eOutside to inside\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e20 – 780 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eNone required, dry service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eCast aluminum, epoxy painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Point\u003c\/td\u003e\n\u003ctd\u003eF.O.B. Ocala, FL 34474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eInstall a Grade D at the outlet of any regenerative desiccant dryer: \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cdt-series-heatless-desiccant-air-dryer\"\u003eCDT heatless\u003c\/a\u003e, \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xchl-series-heatless-desiccant-air-dryer\"\u003eXCHL heatless\u003c\/a\u003e, \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xchp-series-heated-purge-desiccant-air-dryer\"\u003eXCHP heated purge\u003c\/a\u003e, \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xchba-series-heated-blower-purge-desiccant-air-dryer\"\u003eXCHBA blower purge\u003c\/a\u003e, or \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xcmla-series-modular-desiccant-air-dryer\"\u003eXCMLA modular\u003c\/a\u003e. It is standard practice on instrument air systems, blow molding, laser cutting assist gas, powder coating, pharmaceutical and food packaging, and any process where dry, dust-free air is a specification rather than a preference.\u003c\/p\u003e\u003ch2\u003eBuild Your Filtration Train\u003c\/h2\u003e\u003cp\u003eA properly built desiccant installation reads: (1) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-a-mechanical-water-separator\"\u003eGrade A separator\u003c\/a\u003e to remove bulk liquid; (2) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E coalescing prefilter\u003c\/a\u003e to protect the desiccant bed from oil; (3) \u003cstrong\u003edesiccant dryer\u003c\/strong\u003e; (4) \u003cstrong\u003eGrade D afterfilter\u003c\/strong\u003e to catch desiccant fines on the way out.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually, or whenever the differential pressure indicator shows a 5 PSID rise, whichever comes first. A new dryer or a dryer that has just had its desiccant recharged will shed more dust than usual for the first few weeks, so check the indicator more often during that period. \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-d-replacement-filter-element\"\u003eGenuine Champion CF-series Grade D elements\u003c\/a\u003e are listed in the chart above.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series filter ships with the full factory warranty, lifetime application support, and access to our compressed-air engineers for sizing and system design.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eCan I use a Grade C instead of a Grade D after my desiccant dryer?\u003c\/h3\u003e\u003cp\u003eIt will filter, but not as well in this service. The Grade D element is built for outside-to-inside dry dust loading; a Grade C is built for the opposite flow direction and will load its inner surface and blind off sooner.\u003c\/p\u003e\u003ch3\u003eDoes the Grade D need a drain?\u003c\/h3\u003e\u003cp\u003eNo. Air leaving a desiccant dryer is at a very low dew point, so nothing condenses in the housing. That is why the standard Grade D configuration has no drain.\u003c\/p\u003e\u003ch3\u003eWhere exactly does it go?\u003c\/h3\u003e\u003cp\u003eImmediately downstream of the dryer outlet, before the air reaches the plant header, so the fines never get into the distribution piping in the first place.\u003c\/p\u003e\u003ch3\u003eHow do I size it?\u003c\/h3\u003e\u003cp\u003eMatch it to the dryer, or to the actual SCFM at that point. Sizing up lowers pressure drop and extends element life, which matters because pressure drop on a desiccant system is already a real energy cost.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"20 SCFM — 3\/8\" NPTF","offer_id":54781542105363,"sku":"CFL20D11PYTW","price":234.9,"currency_code":"USD","in_stock":true},{"title":"35 SCFM — 1\/2\" NPTF","offer_id":54781542138131,"sku":"CFL35D13PYTW","price":259.2,"currency_code":"USD","in_stock":true},{"title":"60 SCFM — 1\/2\" NPTF","offer_id":54781542170899,"sku":"CFL60D13PYTW","price":372.6,"currency_code":"USD","in_stock":true},{"title":"100 SCFM — 1\" NPTF","offer_id":54781542203667,"sku":"CFL100D17GYTW","price":461.7,"currency_code":"USD","in_stock":true},{"title":"170 SCFM — 1\" NPTF","offer_id":54781542236435,"sku":"CFL170D17GYTW","price":696.6,"currency_code":"USD","in_stock":true},{"title":"250 SCFM — 1-1\/2\" NPTF","offer_id":54781542269203,"sku":"CFL250D21GYTW","price":923.4,"currency_code":"USD","in_stock":true},{"title":"375 SCFM — 1-1\/2\" NPTF","offer_id":54781542301971,"sku":"CFL375D21GYTW","price":1215.0,"currency_code":"USD","in_stock":true},{"title":"485 SCFM — 2\" NPTF","offer_id":54781542334739,"sku":"CFL485D23GYTW","price":1547.1,"currency_code":"USD","in_stock":true},{"title":"625 SCFM — 2-1\/2\" NPTF","offer_id":54781542367507,"sku":"CFL625D25GYTW","price":1830.6,"currency_code":"USD","in_stock":true},{"title":"780 SCFM — 2-1\/2\" NPTF","offer_id":54781542400275,"sku":"CFL780D25GYTW","price":2097.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL1.png?v=1780354005"},{"product_id":"champion-cfl-series-grade-f-maximum-efficiency-coalescing-filter","title":"Champion CFL Series Inline Air Filter – Grade F Maximum Efficiency Oil Removal (20–780 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series Grade F\u003c\/strong\u003e is a \u003cstrong\u003emaximum high efficiency oil removal coalescing filter\u003c\/strong\u003e available in ten flow rates from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e. It removes oil aerosol and submicron particulate down to \u003cstrong\u003e0.01 micron with a residual oil carryover of .0008 ppm by weight\u003c\/strong\u003e, which is one tenth the carryover of a standard high efficiency coalescer. Rated to \u003cstrong\u003e300 PSIG\u003c\/strong\u003e, the Grade F is the final polishing stage for critical air.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and connection size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhen .008 PPM Is Not Clean Enough\u003c\/h2\u003e\u003cp\u003eA \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E coalescing filter\u003c\/a\u003e at .008 ppm is the right specification for the large majority of industrial work. The Grade F exists for the jobs where it is not: breathing air packages, pharmaceutical and food-contact processes, semiconductor and electronics assembly, medical device manufacturing, critical instrumentation, and finishing lines where a single oil defect scraps an expensive part. At .0008 ppm the Grade F is the last line of defense between a lubricated compressor and a process that cannot tolerate oil.\u003c\/p\u003e\u003ch2\u003eISO 8573-1:2010 Air Quality Performance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAerosol and Particle Removal\u003c\/strong\u003e — 0.01 micron, capturing submicron oil aerosol and fine particulate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemaining Oil Content\u003c\/strong\u003e — .0008 ppm w\/w, an order of magnitude below a standard high efficiency coalescer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBest Practice\u003c\/strong\u003e — Run behind a coarser filter. A Grade F installed on raw wet air loads up in weeks; installed as a final stage it runs a full year.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eDimensions (H x W)\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL20F11APYTW\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8 x 4 in\u003c\/td\u003e\n\u003ctd\u003e4.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF20FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL35F13APYTW\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e11 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.1 lb\u003c\/td\u003e\n\u003ctd\u003eCF35FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL60F13APYTW\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e13 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.5 lb\u003c\/td\u003e\n\u003ctd\u003eCF60FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL100F17AGYTW\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e15 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF100FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL170F17AGYTW\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e20 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.9 lb\u003c\/td\u003e\n\u003ctd\u003eCF170FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL250F21AGYTW\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e23 x 6 in\u003c\/td\u003e\n\u003ctd\u003e10.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF250FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL375F21AGYTW\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e27 x 6 in\u003c\/td\u003e\n\u003ctd\u003e11.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF375FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL485F23AGYTW\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e31 x 8 in\u003c\/td\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003ctd\u003eCF485FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625F25AGYTW\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e37 x 8 in\u003c\/td\u003e\n\u003ctd\u003e33 lb\u003c\/td\u003e\n\u003ctd\u003eCF625FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL780F25AGYTW\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e43 x 8 in\u003c\/td\u003e\n\u003ctd\u003e38 lb\u003c\/td\u003e\n\u003ctd\u003eCF780FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eAll ten sizes ship with an internal automatic drain. Models 20 through 60 carry a differential pressure slide indicator, models 100 through 780 a differential pressure gauge. Alternate connection sizes, BSP threads, a liquid level indicator on models 375 and below, and an electronic demand drain are available. Call us and we will configure the part number.\u003c\/p\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e.0008 PPM Residual Oil\u003c\/strong\u003e — The highest oil removal efficiency in the CFL coalescing range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.01 Micron Aerosol Removal\u003c\/strong\u003e — Captures submicron oil mist that passes straight through a general purpose filter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 to 780 SCFM Rated Flow\u003c\/strong\u003e — Ten sizes for point-of-use polishing through full plant treatment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e — 250 PSIG when supplied with the internal automatic drain or liquid level indicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e — Wide operating envelope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Automatic Drain\u003c\/strong\u003e — Standard on every size, so coalesced oil leaves continuously instead of re-entraining.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Indicator\u003c\/strong\u003e — Slide or gauge, so element changes are driven by condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Cast Aluminum Housing\u003c\/strong\u003e — Corrosion resistant, factory pressure tested.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grade\u003c\/td\u003e\n\u003ctd\u003eF — Maximum High Efficiency Oil Removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol \/ Particle Removal\u003c\/td\u003e\n\u003ctd\u003e0.01 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemaining Oil Content\u003c\/td\u003e\n\u003ctd\u003e.0008 ppm w\/w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e20 – 780 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG with manual drain, 250 PSIG with automatic drain or liquid level indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eInternal automatic drain, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eCast aluminum, epoxy painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Point\u003c\/td\u003e\n\u003ctd\u003eF.O.B. Ocala, FL 34474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003ePharmaceutical and food processing, breathing air systems, medical device and semiconductor manufacturing, critical instrument air, laboratory air, precision paint and powder finishing, and any process where a trace of oil is a rejected batch. The Grade F is also the correct prefilter ahead of a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/desiccant-air-dryers\"\u003edesiccant dryer\u003c\/a\u003e on an oil-lubricated system, because oil that reaches a desiccant bed coats the media and permanently destroys its capacity.\u003c\/p\u003e\u003ch2\u003eBuild Your Filtration Train\u003c\/h2\u003e\u003cp\u003eFor critical air, install in this order: (1) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-a-mechanical-water-separator\"\u003eGrade A mechanical separator\u003c\/a\u003e for bulk liquid; (2) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-c-particulate-inline-filter\"\u003eGrade C particulate filter\u003c\/a\u003e for solids; (3) \u003cstrong\u003edryer\u003c\/strong\u003e; (4) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E coalescing filter\u003c\/a\u003e; (5) \u003cstrong\u003eGrade F maximum efficiency coalescing filter\u003c\/strong\u003e; (6) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-g-oil-vapor-removal-carbon-filter\"\u003eGrade G carbon filter\u003c\/a\u003e where oil vapor and odor must also be removed.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually, or whenever the differential pressure indicator shows a 5 PSID rise, whichever comes first. Do not stretch a coalescing element past its interval: a saturated coalescer does not just stop working, it begins re-entraining the oil it already captured and sends it downstream. \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-f-replacement-filter-element\"\u003eGenuine Champion CF-series Grade F elements\u003c\/a\u003e are listed in the chart above.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series filter ships with the full factory warranty, lifetime application support, and access to our compressed-air engineers for sizing and system design.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eGrade E or Grade F?\u003c\/h3\u003e\u003cp\u003eGrade E delivers .008 ppm residual oil and is right for most industrial work. Grade F delivers .0008 ppm and is right where the process specification or an auditor demands it. If you are running breathing air, food contact, or pharma, specify F.\u003c\/p\u003e\u003ch3\u003eCan I install a Grade F by itself?\u003c\/h3\u003e\u003cp\u003eYou can, but it is expensive practice. A fine coalescing element loaded with bulk liquid and pipe scale plugs quickly. Put a separator and a coarser filter in front of it and the Grade F will run a full service year.\u003c\/p\u003e\u003ch3\u003eDoes a Grade F remove oil vapor?\u003c\/h3\u003e\u003cp\u003eNo. Coalescing filters remove liquid oil aerosol, not vapor. For vapor and odor you need an activated carbon stage, which is the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-g-oil-vapor-removal-carbon-filter\"\u003eGrade G\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eHow do I size it?\u003c\/h3\u003e\u003cp\u003eSize to the actual SCFM at that point in the system rather than to compressor horsepower. Oversizing lowers pressure drop and extends element life, both of which pay for themselves in energy.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"20 SCFM — 3\/8\" NPTF","offer_id":54781542826259,"sku":"CFL20F11APYTW","price":356.4,"currency_code":"USD","in_stock":true},{"title":"35 SCFM — 1\/2\" NPTF","offer_id":54781542859027,"sku":"CFL35F13APYTW","price":380.7,"currency_code":"USD","in_stock":true},{"title":"60 SCFM — 1\/2\" NPTF","offer_id":54781542891795,"sku":"CFL60F13APYTW","price":486.0,"currency_code":"USD","in_stock":true},{"title":"100 SCFM — 1\" NPTF","offer_id":54781542924563,"sku":"CFL100F17AGYTW","price":623.7,"currency_code":"USD","in_stock":true},{"title":"170 SCFM — 1\" NPTF","offer_id":54781542957331,"sku":"CFL170F17AGYTW","price":858.6,"currency_code":"USD","in_stock":true},{"title":"250 SCFM — 1-1\/2\" NPTF","offer_id":54781542990099,"sku":"CFL250F21AGYTW","price":1101.6,"currency_code":"USD","in_stock":true},{"title":"375 SCFM — 1-1\/2\" NPTF","offer_id":54781543022867,"sku":"CFL375F21AGYTW","price":1409.4,"currency_code":"USD","in_stock":true},{"title":"485 SCFM — 2\" NPTF","offer_id":54781543055635,"sku":"CFL485F23AGYTW","price":1757.7,"currency_code":"USD","in_stock":true},{"title":"625 SCFM — 2-1\/2\" NPTF","offer_id":54781543088403,"sku":"CFL625F25AGYTW","price":2065.5,"currency_code":"USD","in_stock":true},{"title":"780 SCFM — 2-1\/2\" NPTF","offer_id":54781543121171,"sku":"CFL780F25AGYTW","price":2421.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL1.png?v=1780354005"},{"product_id":"champion-cfl-series-grade-g-oil-vapor-removal-carbon-filter","title":"Champion CFL Series Inline Air Filter – Grade G Activated Carbon Oil Vapor \u0026 Odor Removal (20–780 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series Grade G\u003c\/strong\u003e is an \u003cstrong\u003eactivated carbon oil vapor and odor removal filter\u003c\/strong\u003e available in ten flow rates from \u003cstrong\u003e20 to 780 SCFM\u003c\/strong\u003e. Where a coalescing filter captures liquid oil aerosol, the Grade G adsorbs what is left in the gas phase, taking oil vapor and hydrocarbon odor down to \u003cstrong\u003e.003 ppm\u003c\/strong\u003e at a particle rating of \u003cstrong\u003e0.01 micron\u003c\/strong\u003e. It is the last stage in a treatment train and the only one that addresses smell and taste.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and connection size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhy a Coalescing Filter Cannot Do This Job\u003c\/h2\u003e\u003cp\u003eLubricant that passes a rotary screw airend does not all leave as droplets. A measurable fraction vaporizes at compression temperature and stays a gas the whole way downstream, invisible to any mechanical filter. That vapor is what you smell at the nozzle, what taints a food product, what leaves a haze on a painted panel, and what shows up as hydrocarbon in a breathing air test. Removing it takes adsorption, not filtration, which means a bed of activated carbon. The Grade G packs that bed into the same modular CFL housing as the rest of the family, so it drops into an existing filter stack.\u003c\/p\u003e\u003ch2\u003ePerformance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil Vapor and Odor Removal\u003c\/strong\u003e — Down to .003 ppm remaining hydrocarbon content.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParticle Rating\u003c\/strong\u003e — 0.01 micron.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMandatory Prefiltration\u003c\/strong\u003e — A carbon bed must see dry, oil-free, particulate-free air. Liquid oil will blind a carbon element in days.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eDimensions (H x W)\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL20G11YTW\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e8 x 4 in\u003c\/td\u003e\n\u003ctd\u003e4.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF20GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL35G11YTW\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e11 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.1 lb\u003c\/td\u003e\n\u003ctd\u003eCF35GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL60G11YTW\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/8\" NPTF\u003c\/td\u003e\n\u003ctd\u003e13 x 4 in\u003c\/td\u003e\n\u003ctd\u003e8.5 lb\u003c\/td\u003e\n\u003ctd\u003eCF60GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL100G15YTW\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/4\" NPTF\u003c\/td\u003e\n\u003ctd\u003e15 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF100GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL170G15YTW\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\/4\" NPTF\u003c\/td\u003e\n\u003ctd\u003e20 x 5 in\u003c\/td\u003e\n\u003ctd\u003e6.9 lb\u003c\/td\u003e\n\u003ctd\u003eCF170GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL250G17YTW\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e23 x 6 in\u003c\/td\u003e\n\u003ctd\u003e10.2 lb\u003c\/td\u003e\n\u003ctd\u003eCF250GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL375G17YTW\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003e1\" NPTF\u003c\/td\u003e\n\u003ctd\u003e27 x 6 in\u003c\/td\u003e\n\u003ctd\u003e11.3 lb\u003c\/td\u003e\n\u003ctd\u003eCF375GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL485G23YTW\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003e2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e31 x 8 in\u003c\/td\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003ctd\u003eCF485GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625G25YTW\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e37 x 8 in\u003c\/td\u003e\n\u003ctd\u003e33 lb\u003c\/td\u003e\n\u003ctd\u003eCF625GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL780G25YTW\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003e2-1\/2\" NPTF\u003c\/td\u003e\n\u003ctd\u003e43 x 8 in\u003c\/td\u003e\n\u003ctd\u003e38 lb\u003c\/td\u003e\n\u003ctd\u003eCF780GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe connection sizes above are the standard Champion configurations for Grade G. Each housing also accepts the larger port sizes in its range, up to 1\/2\" on models 20 through 60, 1\" on models 100 and 170, and 1-1\/4\" or 1-1\/2\" on models 250 and 375, as well as BSP threads. A differential pressure slide or gauge, a liquid level indicator on models 375 and below, and an electronic demand drain are all order-entry options. Call us and we will configure the part number.\u003c\/p\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eActivated Carbon Adsorption\u003c\/strong\u003e — Removes what no mechanical filter can touch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e.003 PPM Remaining Oil Vapor\u003c\/strong\u003e — Eliminates hydrocarbon odor and taste.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.01 Micron Particle Rating\u003c\/strong\u003e — Also traps the carbon fines the bed itself sheds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 to 780 SCFM Rated Flow\u003c\/strong\u003e — Ten sizes from a single paint booth to a plant header.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e — 250 PSIG when supplied with an automatic drain or liquid level indicator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e — Adsorption efficiency improves as inlet temperature drops, so cooler is better.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame Modular Housing\u003c\/strong\u003e — Bolts to the rest of the CFL family with a standard connector kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Cast Aluminum Housing\u003c\/strong\u003e — Corrosion resistant, factory pressure tested.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grade\u003c\/td\u003e\n\u003ctd\u003eG — Oil Vapor and Odor Removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eActivated carbon adsorption bed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemaining Oil Vapor\u003c\/td\u003e\n\u003ctd\u003e.003 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticle Rating\u003c\/td\u003e\n\u003ctd\u003e0.01 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e20 – 780 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG with manual drain, 250 PSIG with automatic drain or liquid level indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Prefiltration\u003c\/td\u003e\n\u003ctd\u003eGrade E or Grade F coalescing filter, plus a dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Point\u003c\/td\u003e\n\u003ctd\u003eF.O.B. Ocala, FL 34474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003ePaint and powder finishing where oil vapor causes fisheyes and craters, food and beverage packaging, breathing air systems, pharmaceutical processing, laboratory and analytical air, blow molding of food-grade containers, dental and medical air, and any system where operators complain that the air smells like compressor oil. It is also standard where a plant runs oil-lubricated compressors but has to certify oil-free quality at the point of use.\u003c\/p\u003e\u003ch2\u003eBuild Your Filtration Train\u003c\/h2\u003e\u003cp\u003eThe Grade G always goes last: (1) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-a-mechanical-water-separator\"\u003eGrade A mechanical separator\u003c\/a\u003e; (2) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-c-particulate-inline-filter\"\u003eGrade C particulate filter\u003c\/a\u003e; (3) \u003cstrong\u003edryer\u003c\/strong\u003e; (4) \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E\u003c\/a\u003e or \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-f-maximum-efficiency-coalescing-filter\"\u003eGrade F coalescing filter\u003c\/a\u003e; (5) \u003cstrong\u003eGrade G activated carbon filter\u003c\/strong\u003e. Skipping step 4 is the single most common reason a carbon filter fails early.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eCarbon elements are not judged by differential pressure, because an adsorption bed saturates long before it restricts flow. Replace the Grade G element on a time basis, typically every 6 to 12 months depending on inlet oil loading and duty, or immediately if odor returns at the point of use. That is the practical test: if you can smell oil downstream, the bed is spent no matter what the gauge says. \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-g-replacement-filter-element\"\u003eGenuine Champion CF-series Grade G elements\u003c\/a\u003e are listed in the chart above.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series filter ships with the full factory warranty, lifetime application support, and access to our compressed-air engineers for sizing and system design.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eDoes a Grade G make my air breathing-air certified?\u003c\/h3\u003e\u003cp\u003eNot by itself. A carbon filter is a required component of a breathing air package, but certification also depends on the dryer, on carbon monoxide monitoring, and on the rest of the system meeting Grade D breathing air requirements. Talk to us before you build one.\u003c\/p\u003e\u003ch3\u003eWhy does my carbon filter smell like oil after only a month?\u003c\/h3\u003e\u003cp\u003eAlmost always missing or spent coalescing prefiltration. Liquid oil reaching a carbon bed blinds the adsorption sites very quickly. Check the Grade E or Grade F element ahead of it first.\u003c\/p\u003e\u003ch3\u003eIs there a differential pressure indicator?\u003c\/h3\u003e\u003cp\u003eIt is available as an order option, but it is not the right maintenance signal for carbon. Pressure drop stays low right up until the bed is exhausted. Change on time, not on differential.\u003c\/p\u003e\u003ch3\u003eHow do I size it?\u003c\/h3\u003e\u003cp\u003eSize to the actual SCFM at that point in the system. Oversizing a carbon filter is genuinely worthwhile here, because lower face velocity means longer contact time with the bed, better adsorption, and a longer element life.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"20 SCFM — 3\/8\" NPTF","offer_id":54781547381011,"sku":"CFL20G11YTW","price":226.8,"currency_code":"USD","in_stock":true},{"title":"35 SCFM — 3\/8\" NPTF","offer_id":54781547413779,"sku":"CFL35G11YTW","price":251.1,"currency_code":"USD","in_stock":true},{"title":"60 SCFM — 3\/8\" NPTF","offer_id":54781547446547,"sku":"CFL60G11YTW","price":356.4,"currency_code":"USD","in_stock":true},{"title":"100 SCFM — 3\/4\" NPTF","offer_id":54781547479315,"sku":"CFL100G15YTW","price":461.7,"currency_code":"USD","in_stock":true},{"title":"170 SCFM — 3\/4\" NPTF","offer_id":54781547512083,"sku":"CFL170G15YTW","price":712.8,"currency_code":"USD","in_stock":true},{"title":"250 SCFM — 1\" NPTF","offer_id":54781547544851,"sku":"CFL250G17YTW","price":955.8,"currency_code":"USD","in_stock":true},{"title":"375 SCFM — 1\" NPTF","offer_id":54781547577619,"sku":"CFL375G17YTW","price":1239.3,"currency_code":"USD","in_stock":true},{"title":"485 SCFM — 2\" NPTF","offer_id":54781547610387,"sku":"CFL485G23YTW","price":1652.4,"currency_code":"USD","in_stock":true},{"title":"625 SCFM — 2-1\/2\" NPTF","offer_id":54781547643155,"sku":"CFL625G25YTW","price":1944.0,"currency_code":"USD","in_stock":true},{"title":"780 SCFM — 2-1\/2\" NPTF","offer_id":54781547675923,"sku":"CFL780G25YTW","price":2365.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL1.png?v=1780354005"},{"product_id":"champion-cfl-series-grade-a-replacement-filter-element","title":"Champion CFL Series Replacement Element – Grade A Mechanical Water Separator (20–780 SCFM)","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion CFL Series Grade A replacement separator elements\u003c\/strong\u003e, part numbers \u003cstrong\u003eCF20AE through CF780AE\u003c\/strong\u003e, for the full range of \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-a-mechanical-water-separator\"\u003eChampion CFL Grade A mechanical moisture separators\u003c\/a\u003e from 20 to 780 SCFM. These are the factory elements, not aftermarket copies, and they carry the Champion warranty.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect the element that matches your housing size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhich Element Do I Need?\u003c\/h2\u003e\u003cp\u003eMatch the element to the flow number stamped in your housing part number, not to your compressor size. A CFL100A housing takes a CF100AE element regardless of which drain, indicator, or connection options were specified when it was ordered. The letters near the end of a CFL part number describe the drain and the differential pressure indicator; they never change which element goes inside.\u003c\/p\u003e\u003ch2\u003eElement Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement P\/N\u003c\/th\u003e\n\u003cth\u003eHousing Flow\u003c\/th\u003e\n\u003cth\u003eFits Housing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF20AE\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF35AE\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL35A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF60AE\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF100AE\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF170AE\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL170A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF250AE\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF375AE\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL375A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF485AE\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL485A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF625AE\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL625A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF780AE\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL780A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrade\u003c\/td\u003e\n\u003ctd\u003eA — Mechanical Separator Element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCentrifugal separation of bulk liquid water and oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulk Liquid Removal\u003c\/td\u003e\n\u003ctd\u003eUp to 99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003eMatches the housing, 300 PSIG maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eStainless steel separator element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eChampion CFL Grade A housings, 20 through 780 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eService Interval\u003c\/h2\u003e\u003cp\u003eA Grade A separator element is not a consumable media cartridge the way a coalescing element is. There is no annual replacement schedule. Inspect it at each scheduled shutdown, clean off any scale or sludge it has collected, and replace it if the element is corroded, deformed, or damaged. Far more often, the part that needs attention on a separator is the drain: a drain stuck closed floods the housing and carries liquid downstream, while a drain stuck open bleeds compressed air continuously and quietly costs real money.\u003c\/p\u003e\u003ch2\u003eWhy Genuine Champion Elements\u003c\/h2\u003e\u003cp\u003eSeparator element geometry sets the swirl velocity inside the housing, and swirl velocity is what determines separation efficiency. An element with the wrong vane geometry fits the housing and still fails to separate. Genuine Champion elements maintain the rated performance and keep your Champion warranty intact.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. We stock the CFL element range, ship same day on in-stock part numbers, and our compressed-air engineers will cross-reference your existing part number if you are not sure what you have.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow do I find my element part number?\u003c\/h3\u003e\u003cp\u003eRead the housing part number off the label. A CFL375CAG housing takes a CF375-series element; the number after CFL is the flow size and the grade letter follows it. Call us with the housing part number if the label is unreadable.\u003c\/p\u003e\u003ch3\u003eCan I use a Grade A element in a Grade C housing?\u003c\/h3\u003e\u003cp\u003eNo. The housings share a body casting but the elements are different devices. A separator element in a filter housing will not filter, and a filter element in a separator housing will load up with liquid and collapse.\u003c\/p\u003e\u003ch3\u003eDo I need to depressurize before changing an element?\u003c\/h3\u003e\u003cp\u003eAlways. Isolate the filter, bleed it to zero pressure, and confirm at the drain before opening the bowl.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"CF20AE — 20 SCFM","offer_id":54781547839763,"sku":"CF20AE","price":61.56,"currency_code":"USD","in_stock":true},{"title":"CF35AE — 35 SCFM","offer_id":54781547872531,"sku":"CF35AE","price":64.8,"currency_code":"USD","in_stock":true},{"title":"CF60AE — 60 SCFM","offer_id":54781547905299,"sku":"CF60AE","price":89.91,"currency_code":"USD","in_stock":true},{"title":"CF100AE — 100 SCFM","offer_id":54781547938067,"sku":"CF100AE","price":187.11,"currency_code":"USD","in_stock":true},{"title":"CF170AE — 170 SCFM","offer_id":54781547970835,"sku":"CF170AE","price":138.51,"currency_code":"USD","in_stock":true},{"title":"CF250AE — 250 SCFM","offer_id":54781548003603,"sku":"CF250AE","price":179.01,"currency_code":"USD","in_stock":true},{"title":"CF375AE — 375 SCFM","offer_id":54781548036371,"sku":"CF375AE","price":235.71,"currency_code":"USD","in_stock":true},{"title":"CF485AE — 485 SCFM","offer_id":54781548069139,"sku":"CF485AE","price":304.56,"currency_code":"USD","in_stock":true},{"title":"CF625AE — 625 SCFM","offer_id":54781548101907,"sku":"CF625AE","price":313.47,"currency_code":"USD","in_stock":true},{"title":"CF780AE — 780 SCFM","offer_id":54781548134675,"sku":"CF780AE","price":306.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL-cutaway.png?v=1780354006"},{"product_id":"champion-cfl-series-grade-b-replacement-filter-element","title":"Champion CFL Series Replacement Filter Element – Grade B General Purpose 3 Micron (20–780 SCFM)","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion CFL Series Grade B replacement filter elements\u003c\/strong\u003e, part numbers \u003cstrong\u003eCF20BE through CF780BE\u003c\/strong\u003e, for the full range of \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-b-general-purpose-separator-filter\"\u003eChampion CFL Grade B separator\/filters\u003c\/a\u003e from 20 to 780 SCFM. Grade B media filters to \u003cstrong\u003e3 micron with a residual oil carryover of 5 ppm\u003c\/strong\u003e, the general purpose specification for plant air, tools, and cylinders.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect the element that matches your housing size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhich Element Do I Need?\u003c\/h2\u003e\u003cp\u003eMatch the element to the flow number in your housing part number, not to your compressor size. A CFL250BG housing takes a CF250BE element regardless of which drain, indicator, or connection options were specified at order entry. The trailing letters on a CFL part number describe drain and indicator choices; they never change which element goes inside.\u003c\/p\u003e\u003ch2\u003eElement Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement P\/N\u003c\/th\u003e\n\u003cth\u003eHousing Flow\u003c\/th\u003e\n\u003cth\u003eFits Housing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF20BE\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL20B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF35BE\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL35B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF60BE\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL60B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF100BE\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL100B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF170BE\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL170B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF250BE\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL250B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF375BE\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL375B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF485BE\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL485B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF625BE\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL625B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF780BE\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL780B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrade\u003c\/td\u003e\n\u003ctd\u003eB — General Purpose Separator \/ Filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticle Removal\u003c\/td\u003e\n\u003ctd\u003e3 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemaining Oil Content\u003c\/td\u003e\n\u003ctd\u003e5 ppm w\/w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003eMatches the housing, 300 PSIG maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore\u003c\/td\u003e\n\u003ctd\u003e409 stainless steel standard, 304 stainless available on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eChampion CFL Grade B housings, 20 through 780 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eService Interval\u003c\/h2\u003e\u003cp\u003eReplace the element annually, or whenever the differential pressure indicator on the housing shows a 5 PSID rise above clean, whichever comes first. Pressure drop across a compressed-air filter is a direct energy cost at roughly 1% of compressor horsepower per PSID, so a neglected element is not a saving. It is also a rupture risk: a fully loaded element eventually collapses and dumps everything it has collected into the plant header.\u003c\/p\u003e\u003ch2\u003eWhy Genuine Champion Elements\u003c\/h2\u003e\u003cp\u003eMedia grade, pleat count, and end-cap sealing are what deliver the rated 3 micron and 5 ppm performance. A generic element that physically fits the bowl can bypass at the end cap and quietly deliver a fraction of the rated efficiency while the differential pressure gauge reads perfectly normal. Genuine Champion elements also keep the housing warranty intact.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. We stock the CFL element range, ship same day on in-stock part numbers, and our compressed-air engineers will cross-reference your existing part number if you are not sure what you have.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow do I find my element part number?\u003c\/h3\u003e\u003cp\u003eRead the housing part number off the label. A CFL375BG housing takes CF375BE. If the label is gone, measure the housing height and call us; the sizes are distinctive.\u003c\/p\u003e\u003ch3\u003eCan I upgrade to a finer element in the same housing?\u003c\/h3\u003e\u003cp\u003eThe CFL housings share a body casting across grades, but elements are matched to the grade the housing was built as, including its flow direction and drain arrangement. Do not substitute grades without checking with us first.\u003c\/p\u003e\u003ch3\u003eShould I change the element on a schedule or on differential pressure?\u003c\/h3\u003e\u003cp\u003eWhichever comes first. Annual replacement is the backstop, because filter media degrades with age even on light duty. The differential pressure indicator catches the heavy-duty case where the element loads up well before the year is out.\u003c\/p\u003e\u003ch3\u003eDo I need to depressurize before changing an element?\u003c\/h3\u003e\u003cp\u003eAlways. Isolate the filter, bleed it to zero pressure, and confirm at the drain before opening the bowl.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"CF20BE — 20 SCFM","offer_id":54781548200211,"sku":"CF20BE","price":86.67,"currency_code":"USD","in_stock":true},{"title":"CF35BE — 35 SCFM","offer_id":54781548232979,"sku":"CF35BE","price":93.15,"currency_code":"USD","in_stock":true},{"title":"CF60BE — 60 SCFM","offer_id":54781548265747,"sku":"CF60BE","price":137.7,"currency_code":"USD","in_stock":true},{"title":"CF100BE — 100 SCFM","offer_id":54781548298515,"sku":"CF100BE","price":152.28,"currency_code":"USD","in_stock":true},{"title":"CF170BE — 170 SCFM","offer_id":54781548331283,"sku":"CF170BE","price":206.55,"currency_code":"USD","in_stock":true},{"title":"CF250BE — 250 SCFM","offer_id":54781548364051,"sku":"CF250BE","price":291.6,"currency_code":"USD","in_stock":true},{"title":"CF375BE — 375 SCFM","offer_id":54781548396819,"sku":"CF375BE","price":392.04,"currency_code":"USD","in_stock":true},{"title":"CF485BE — 485 SCFM","offer_id":54781548429587,"sku":"CF485BE","price":465.75,"currency_code":"USD","in_stock":true},{"title":"CF625BE — 625 SCFM","offer_id":54781548462355,"sku":"CF625BE","price":487.62,"currency_code":"USD","in_stock":true},{"title":"CF780BE — 780 SCFM","offer_id":54781548495123,"sku":"CF780BE","price":517.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL-cutaway.png?v=1780354006"},{"product_id":"champion-cfl-series-grade-d-replacement-filter-element","title":"Champion CFL Series Replacement Filter Element – Grade D Dry Particulate Desiccant Afterfilter (20–780 SCFM)","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion CFL Series Grade D replacement filter elements\u003c\/strong\u003e, part numbers \u003cstrong\u003eCF20DE through CF780DE\u003c\/strong\u003e, for the full range of \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-d-dry-particulate-afterfilter\"\u003eChampion CFL Grade D dry particulate afterfilters\u003c\/a\u003e from 20 to 780 SCFM. Grade D media captures desiccant dust and dry particulate down to \u003cstrong\u003e1 micron\u003c\/strong\u003e and is built for \u003cstrong\u003eoutside-to-inside flow\u003c\/strong\u003e, which is what makes it the correct element for the outlet of a desiccant dryer.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect the element that matches your housing size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhich Element Do I Need?\u003c\/h2\u003e\u003cp\u003eMatch the element to the flow number in your housing part number. A CFL170DG housing takes a CF170DE element regardless of which indicator or connection options were specified at order entry.\u003c\/p\u003e\u003ch2\u003eElement Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement P\/N\u003c\/th\u003e\n\u003cth\u003eHousing Flow\u003c\/th\u003e\n\u003cth\u003eFits Housing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF20DE\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL20D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF35DE\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL35D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF60DE\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL60D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF100DE\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL100D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF170DE\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL170D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF250DE\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL250D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF375DE\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL375D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF485DE\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL485D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF625DE\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL625D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF780DE\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL780D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrade\u003c\/td\u003e\n\u003ctd\u003eD — Dry Particulate Afterfilter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticle Removal\u003c\/td\u003e\n\u003ctd\u003e1 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eOutside to inside\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003eMatches the housing, 300 PSIG maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService\u003c\/td\u003e\n\u003ctd\u003eDry air only, downstream of a desiccant dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eChampion CFL Grade D housings, 20 through 780 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eService Interval\u003c\/h2\u003e\u003cp\u003eReplace annually, or whenever the differential pressure indicator shows a 5 PSID rise above clean, whichever comes first. Check more often in the first weeks after a desiccant dryer is commissioned or recharged, because a fresh bed sheds noticeably more dust while the beads polish against each other. If the indicator is climbing fast on a mature dryer, that is a signal worth investigating: it usually means the bed is breaking down and the desiccant itself is due for replacement.\u003c\/p\u003e\u003ch2\u003eWhy Genuine Champion Elements\u003c\/h2\u003e\u003cp\u003eThe Grade D element is specifically built to load dust on its outer surface. An element intended for inside-to-outside coalescing service, installed in the same bowl, presents a fraction of the dirt-holding area to the dust and plugs in a fraction of the time. Genuine Champion elements hold the rated 1 micron performance and keep the housing warranty intact.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor and a full-line source for \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/desiccant-air-dryers\"\u003eChampion desiccant dryers\u003c\/a\u003e and their service parts. We ship same day on in-stock part numbers and our engineers will cross-reference your existing part number if you are not sure what you have.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eMy afterfilter element is grey and dusty. Is that normal?\u003c\/h3\u003e\u003cp\u003eYes, that is exactly what it is there for. Grey powder on the outer surface is abraded desiccant. Heavy caking within a few months on a dryer that is not newly commissioned suggests the desiccant bed needs attention.\u003c\/p\u003e\u003ch3\u003eCan I blow the element out and reuse it?\u003c\/h3\u003e\u003cp\u003eNo. Back-blowing drives fines deeper into the media and can rupture it. Replace it.\u003c\/p\u003e\u003ch3\u003eCan I use a Grade C element instead?\u003c\/h3\u003e\u003cp\u003eIt will fit the family but it is the wrong flow direction for dust service and will plug much sooner. Use the Grade D.\u003c\/p\u003e\u003ch3\u003eDo I need to depressurize before changing an element?\u003c\/h3\u003e\u003cp\u003eAlways. Isolate the filter and bleed it to zero pressure before opening the bowl.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"CF20DE — 20 SCFM","offer_id":54781548724499,"sku":"CF20DE","price":59.13,"currency_code":"USD","in_stock":true},{"title":"CF35DE — 35 SCFM","offer_id":54781548757267,"sku":"CF35DE","price":72.9,"currency_code":"USD","in_stock":true},{"title":"CF60DE — 60 SCFM","offer_id":54781548790035,"sku":"CF60DE","price":105.3,"currency_code":"USD","in_stock":true},{"title":"CF100DE — 100 SCFM","offer_id":54781548822803,"sku":"CF100DE","price":129.6,"currency_code":"USD","in_stock":true},{"title":"CF170DE — 170 SCFM","offer_id":54781548855571,"sku":"CF170DE","price":221.13,"currency_code":"USD","in_stock":true},{"title":"CF250DE — 250 SCFM","offer_id":54781548888339,"sku":"CF250DE","price":237.33,"currency_code":"USD","in_stock":true},{"title":"CF375DE — 375 SCFM","offer_id":54781548921107,"sku":"CF375DE","price":235.71,"currency_code":"USD","in_stock":true},{"title":"CF485DE — 485 SCFM","offer_id":54781548953875,"sku":"CF485DE","price":244.62,"currency_code":"USD","in_stock":true},{"title":"CF625DE — 625 SCFM","offer_id":54781548986643,"sku":"CF625DE","price":255.15,"currency_code":"USD","in_stock":true},{"title":"CF780DE — 780 SCFM","offer_id":54781549019411,"sku":"CF780DE","price":873.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFLElement-GradesC_D.jpg?v=1780407597"},{"product_id":"champion-cfl-series-grade-f-replacement-filter-element","title":"Champion CFL Series Replacement Filter Element – Grade F Maximum Efficiency Oil Removal (20–780 SCFM)","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion CFL Series Grade F replacement filter elements\u003c\/strong\u003e, part numbers \u003cstrong\u003eCF20FE through CF780FE\u003c\/strong\u003e, for the full range of \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-f-maximum-efficiency-coalescing-filter\"\u003eChampion CFL Grade F maximum efficiency coalescing filters\u003c\/a\u003e from 20 to 780 SCFM. Grade F media removes oil aerosol and submicron particulate at \u003cstrong\u003e0.01 micron\u003c\/strong\u003e down to a residual oil content of \u003cstrong\u003e.0008 ppm\u003c\/strong\u003e, the finest coalescing specification in the CFL range.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect the element that matches your housing size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhich Element Do I Need?\u003c\/h2\u003e\u003cp\u003eMatch the element to the flow number in your housing part number. A CFL485FAG housing takes a CF485FE element regardless of which drain, indicator, or connection options were specified at order entry.\u003c\/p\u003e\u003ch2\u003eElement Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement P\/N\u003c\/th\u003e\n\u003cth\u003eHousing Flow\u003c\/th\u003e\n\u003cth\u003eFits Housing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF20FE\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL20F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF35FE\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL35F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF60FE\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL60F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF100FE\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL100F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF170FE\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL170F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF250FE\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL250F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF375FE\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL375F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF485FE\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL485F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF625FE\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL625F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF780FE\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL780F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrade\u003c\/td\u003e\n\u003ctd\u003eF — Maximum High Efficiency Oil Removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol \/ Particle Removal\u003c\/td\u003e\n\u003ctd\u003e0.01 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemaining Oil Content\u003c\/td\u003e\n\u003ctd\u003e.0008 ppm w\/w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003eMatches the housing, 300 PSIG maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eBorosilicate coalescing media with drainage layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eChampion CFL Grade F housings, 20 through 780 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eService Interval\u003c\/h2\u003e\u003cp\u003eReplace annually, or whenever the differential pressure indicator shows a 5 PSID rise above clean, whichever comes first. A coalescing element that is run past its interval does not simply stop improving the air; a saturated coalescer re-entrains the oil it has already captured and pushes it downstream, which is worse than no filter at all on a process that is specified for .0008 ppm. On critical air, annual replacement is the minimum discipline regardless of what the gauge reads.\u003c\/p\u003e\u003ch2\u003eWhy Genuine Champion Elements\u003c\/h2\u003e\u003cp\u003eAt this efficiency, performance lives in details a generic element does not reproduce: borosilicate fiber diameter, the drainage layer that carries coalesced oil to the bottom of the element, and the end-cap seal that prevents bypass. A copy element that fits the bowl can deliver a fraction of the rated efficiency with no visible symptom at all, because pressure drop looks normal while oil passes straight through. Genuine Champion elements hold the rated performance and keep the housing warranty intact.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. We stock the CFL element range, ship same day on in-stock part numbers, and our compressed-air engineers will cross-reference your existing part number if you are not sure what you have.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow is a Grade F element different from a Grade E?\u003c\/h3\u003e\u003cp\u003eSame housing, finer media. Grade E delivers .008 ppm residual oil and Grade F delivers .0008 ppm. Grade F costs more per element and carries slightly higher pressure drop, which is the trade you make for an order of magnitude less oil.\u003c\/p\u003e\u003ch3\u003eWhy did my element load up in two months?\u003c\/h3\u003e\u003cp\u003eNearly always inadequate prefiltration. A fine coalescing element installed on raw wet air will plug fast. Put a separator and a coarser filter upstream and the Grade F will run a full year.\u003c\/p\u003e\u003ch3\u003eCan I clean and reuse a coalescing element?\u003c\/h3\u003e\u003cp\u003eNo. Coalescing media works by depth capture. Washing or blowing it out destroys the fiber matrix.\u003c\/p\u003e\u003ch3\u003eDo I need to depressurize before changing an element?\u003c\/h3\u003e\u003cp\u003eAlways. Isolate the filter, bleed it to zero pressure, and confirm at the drain before opening the bowl.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"CF20FE — 20 SCFM","offer_id":54781549052179,"sku":"CF20FE","price":76.14,"currency_code":"USD","in_stock":true},{"title":"CF35FE — 35 SCFM","offer_id":54781549084947,"sku":"CF35FE","price":89.1,"currency_code":"USD","in_stock":true},{"title":"CF60FE — 60 SCFM","offer_id":54781549117715,"sku":"CF60FE","price":115.02,"currency_code":"USD","in_stock":true},{"title":"CF100FE — 100 SCFM","offer_id":54781549150483,"sku":"CF100FE","price":187.92,"currency_code":"USD","in_stock":true},{"title":"CF170FE — 170 SCFM","offer_id":54781549183251,"sku":"CF170FE","price":231.66,"currency_code":"USD","in_stock":true},{"title":"CF250FE — 250 SCFM","offer_id":54781549216019,"sku":"CF250FE","price":271.35,"currency_code":"USD","in_stock":true},{"title":"CF375FE — 375 SCFM","offer_id":54781549248787,"sku":"CF375FE","price":338.58,"currency_code":"USD","in_stock":true},{"title":"CF485FE — 485 SCFM","offer_id":54781549281555,"sku":"CF485FE","price":1267.65,"currency_code":"USD","in_stock":true},{"title":"CF625FE — 625 SCFM","offer_id":54781549314323,"sku":"CF625FE","price":450.36,"currency_code":"USD","in_stock":true},{"title":"CF780FE — 780 SCFM","offer_id":54781549347091,"sku":"CF780FE","price":580.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFLElement-GradesE_F.jpg?v=1780354007"},{"product_id":"champion-cfl-series-grade-g-replacement-filter-element","title":"Champion CFL Series Replacement Carbon Element – Grade G Oil Vapor \u0026 Odor Removal (20–780 SCFM)","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion CFL Series Grade G replacement activated carbon elements\u003c\/strong\u003e, part numbers \u003cstrong\u003eCF20GE through CF780GE\u003c\/strong\u003e, for the full range of \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-g-oil-vapor-removal-carbon-filter\"\u003eChampion CFL Grade G oil vapor and odor removal filters\u003c\/a\u003e from 20 to 780 SCFM. Grade G elements adsorb hydrocarbon vapor and odor down to \u003cstrong\u003e.003 ppm\u003c\/strong\u003e at a particle rating of \u003cstrong\u003e0.01 micron\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect the element that matches your housing size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhich Element Do I Need?\u003c\/h2\u003e\u003cp\u003eMatch the element to the flow number in your housing part number. A CFL250G17 housing takes a CF250GE element regardless of which connection size or options were specified at order entry.\u003c\/p\u003e\u003ch2\u003eElement Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement P\/N\u003c\/th\u003e\n\u003cth\u003eHousing Flow\u003c\/th\u003e\n\u003cth\u003eFits Housing\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF20GE\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL20G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF35GE\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL35G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF60GE\u003c\/td\u003e\n\u003ctd\u003e60 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL60G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF100GE\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF170GE\u003c\/td\u003e\n\u003ctd\u003e170 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL170G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF250GE\u003c\/td\u003e\n\u003ctd\u003e250 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL250G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF375GE\u003c\/td\u003e\n\u003ctd\u003e375 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL375G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF485GE\u003c\/td\u003e\n\u003ctd\u003e485 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL485G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF625GE\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL625G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF780GE\u003c\/td\u003e\n\u003ctd\u003e780 SCFM\u003c\/td\u003e\n\u003ctd\u003eCFL780G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrade\u003c\/td\u003e\n\u003ctd\u003eG — Oil Vapor and Odor Removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eActivated carbon adsorption bed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemaining Oil Vapor\u003c\/td\u003e\n\u003ctd\u003e.003 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticle Rating\u003c\/td\u003e\n\u003ctd\u003e0.01 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003eMatches the housing, 300 PSIG maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Upstream\u003c\/td\u003e\n\u003ctd\u003eGrade E or Grade F coalescing filter, plus a dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eChampion CFL Grade G housings, 20 through 780 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eService Interval: Change on Time, Not on Pressure\u003c\/h2\u003e\u003cp\u003eAn activated carbon element is the one filter in the CFL family that you must not manage by differential pressure. An adsorption bed saturates long before it restricts flow, so the gauge stays low and steady right up to the moment the element stops working. Replace a Grade G element every 6 to 12 months depending on inlet oil loading and duty, and immediately if odor returns at the point of use. The nose is a better instrument than the gauge here: if you can smell oil downstream, the bed is spent.\u003c\/p\u003e\u003ch2\u003eProtect the Element You Just Paid For\u003c\/h2\u003e\u003cp\u003eCarbon is destroyed by liquid. Oil aerosol reaching the bed blinds the adsorption sites in days rather than months, and liquid water does the same. Every Grade G element needs a working \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-e-coalescing-inline-filter\"\u003eGrade E\u003c\/a\u003e or \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-grade-f-maximum-efficiency-coalescing-filter\"\u003eGrade F coalescing filter\u003c\/a\u003e and a dryer ahead of it. If a carbon element failed early, check the coalescing element upstream before replacing the carbon again.\u003c\/p\u003e\u003ch2\u003eWhy Genuine Champion Elements\u003c\/h2\u003e\u003cp\u003eAdsorption capacity is a function of carbon quality, bed mass, and contact time, none of which you can see by looking at an element. A lower-grade carbon fill in an identical-looking cartridge can have a fraction of the service life while giving no outward sign at all. Genuine Champion elements hold the rated .003 ppm performance and keep your housing warranty intact.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. We stock the CFL element range, ship same day on in-stock part numbers, and our compressed-air engineers will cross-reference your existing part number if you are not sure what you have.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow do I know when to change it?\u003c\/h3\u003e\u003cp\u003eOn a calendar, at 6 to 12 months, and immediately if odor comes back at the point of use. Do not wait for a pressure drop reading, because it will not come.\u003c\/p\u003e\u003ch3\u003eCan I regenerate an activated carbon element?\u003c\/h3\u003e\u003cp\u003eNot in the field. Industrial carbon regeneration requires high temperature in a controlled furnace. Replace the element.\u003c\/p\u003e\u003ch3\u003eMy new carbon element smelled fine for a week then went bad. Why?\u003c\/h3\u003e\u003cp\u003eAlmost certainly oil carryover from a failed or missing coalescing prefilter. Fix the upstream stage first, otherwise you will keep buying carbon elements.\u003c\/p\u003e\u003ch3\u003eDo I need to depressurize before changing an element?\u003c\/h3\u003e\u003cp\u003eAlways. Isolate the filter, bleed it to zero pressure, and confirm at the drain before opening the bowl.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"CF20GE — 20 SCFM","offer_id":54781549609235,"sku":"CF20GE","price":100.44,"currency_code":"USD","in_stock":true},{"title":"CF35GE — 35 SCFM","offer_id":54781549642003,"sku":"CF35GE","price":107.73,"currency_code":"USD","in_stock":true},{"title":"CF60GE — 60 SCFM","offer_id":54781549674771,"sku":"CF60GE","price":138.51,"currency_code":"USD","in_stock":true},{"title":"CF100GE — 100 SCFM","offer_id":54781549707539,"sku":"CF100GE","price":239.76,"currency_code":"USD","in_stock":true},{"title":"CF170GE — 170 SCFM","offer_id":54781549740307,"sku":"CF170GE","price":297.27,"currency_code":"USD","in_stock":true},{"title":"CF250GE — 250 SCFM","offer_id":54781549773075,"sku":"CF250GE","price":331.29,"currency_code":"USD","in_stock":true},{"title":"CF375GE — 375 SCFM","offer_id":54781549805843,"sku":"CF375GE","price":365.31,"currency_code":"USD","in_stock":true},{"title":"CF485GE — 485 SCFM","offer_id":54781549838611,"sku":"CF485GE","price":481.14,"currency_code":"USD","in_stock":true},{"title":"CF625GE — 625 SCFM","offer_id":54781549871379,"sku":"CF625GE","price":530.55,"currency_code":"USD","in_stock":true},{"title":"CF780GE — 780 SCFM","offer_id":54781549904147,"sku":"CF780GE","price":711.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/CFL-cutaway.png?v=1780354006"},{"product_id":"champion-cfl-series-pressure-vessel-air-filter","title":"Champion CFL Series Pressure Vessel Compressed Air Filter – Grades A–G, 3\" NPTM (625–1,250 SCFM)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion CFL Series pressure vessel filters\u003c\/strong\u003e are the large-capacity end of the CFL family, covering \u003cstrong\u003e625, 1,000 and 1,250 SCFM\u003c\/strong\u003e on \u003cstrong\u003e3\" NPTM\u003c\/strong\u003e connections. Where the modular CFL housings from 20 to 780 SCFM use a bayonet head and bowl, these are welded pressure vessels built to major pressure vessel directives in the Americas, Europe and Asia, with a large-diameter element chamber that keeps pressure drop low at plant-air flow rates.\u003c\/p\u003e\u003cp\u003eEvery one of the seven Champion filter grades is available in all three vessel sizes, so a single housing platform can be configured as a mechanical water separator, a general purpose particulate filter, a desiccant afterfilter, a high efficiency coalescer or an activated carbon oil vapor filter.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your flow rate and filter grade from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhy a Pressure Vessel Housing Instead of a Modular Housing\u003c\/h2\u003e\u003cp\u003eAbove roughly 600 SCFM the physics change. A modular housing sized for 780 SCFM is already running a high face velocity through the element, and pushing more air through it costs real energy in differential pressure. The CFL pressure vessels put a much larger element in a much larger chamber, which drops the face velocity, holds the clean-condition pressure drop down, and stretches the interval between element changes. Because roughly one percent of compressor horsepower is consumed for every PSID of pressure drop in the system, that lower differential pressure pays for itself on a plant-air system running continuously.\u003c\/p\u003e\u003cp\u003eThe vessels also take a 3\" NPTM male pipe connection rather than the female modular ports, which is the natural tie-in size for headers feeding \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-dryers\"\u003elarge refrigerated and desiccant dryers\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003cp\u003eAll models are supplied with a differential pressure gauge and use 3\" NPTM connections. The 1,000 and 1,250 SCFM vessels ship with drain plugs as standard; externally mounted automatic drains are available.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel (CCN)\u003c\/th\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eConnection\u003c\/th\u003e\n\u003cth\u003eDimensions H x W\u003c\/th\u003e\n\u003cth\u003eShip Weight\u003c\/th\u003e\n\u003cth\u003eReplacement Element\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000A27YTW\u003c\/td\u003e\n\u003ctd\u003eA Mechanical Separator\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250A27YTW\u003c\/td\u003e\n\u003ctd\u003eA Mechanical Separator\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPAE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625B27GYTW\u003c\/td\u003e\n\u003ctd\u003eB Separator\/Filter\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000B27GYTW\u003c\/td\u003e\n\u003ctd\u003eB Separator\/Filter\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250B27GYTW\u003c\/td\u003e\n\u003ctd\u003eB Separator\/Filter\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625C27AGYTW\u003c\/td\u003e\n\u003ctd\u003eC Air Line Filter\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000C27GYTW\u003c\/td\u003e\n\u003ctd\u003eC Air Line Filter\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250C27GYTW\u003c\/td\u003e\n\u003ctd\u003eC Air Line Filter\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625D27GYTW\u003c\/td\u003e\n\u003ctd\u003eD Dry Particulate\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000D27GYTW\u003c\/td\u003e\n\u003ctd\u003eD Dry Particulate\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000DE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250D27GYTW\u003c\/td\u003e\n\u003ctd\u003eD Dry Particulate\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625E27AYTW\u003c\/td\u003e\n\u003ctd\u003eE High Efficiency\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000E27GYTW\u003c\/td\u003e\n\u003ctd\u003eE High Efficiency\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000EE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250E27GYTW\u003c\/td\u003e\n\u003ctd\u003eE High Efficiency\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625F27AYTW\u003c\/td\u003e\n\u003ctd\u003eF Max Efficiency\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000F27GYTW\u003c\/td\u003e\n\u003ctd\u003eF Max Efficiency\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250F27GYTW\u003c\/td\u003e\n\u003ctd\u003eF Max Efficiency\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625G27YTW\u003c\/td\u003e\n\u003ctd\u003eG Oil Vapor Carbon\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e40.88 x 10.25 in\u003c\/td\u003e\n\u003ctd\u003e37 lb\u003c\/td\u003e\n\u003ctd\u003eCPGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000G27YTW\u003c\/td\u003e\n\u003ctd\u003eG Oil Vapor Carbon\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eC1000GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250G27YTW\u003c\/td\u003e\n\u003ctd\u003eG Oil Vapor Carbon\u003c\/td\u003e\n\u003ctd\u003e1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM\u003c\/td\u003e\n\u003ctd\u003e48.00 x 16.00 in\u003c\/td\u003e\n\u003ctd\u003e93 lb\u003c\/td\u003e\n\u003ctd\u003eCPGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eThe 625 SCFM Grade A mechanical separator vessel is not listed above. The August 2026 Champion price list prints it at the same figure as the smaller modular CFL625A25 housing, which does not agree with the pricing of the other six grades on the same vessel, so it has been held back pending factory confirmation. Call us and we will quote it from the factory.\u003c\/p\u003e\u003ch2\u003eFilter Grade Selection Guide\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003ePerformance\u003c\/th\u003e\n\u003cth\u003eTypical Position\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eMechanical water separator\u003c\/td\u003e\n\u003ctd\u003eCentrifugal bulk liquid removal, no element to replace on the separator principle\u003c\/td\u003e\n\u003ctd\u003eDirectly at the compressor or aftercooler discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose separator\/filter\u003c\/td\u003e\n\u003ctd\u003e3 micron, 5 ppm remaining oil\u003c\/td\u003e\n\u003ctd\u003eFirst stage bulk protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eAir line particulate filter\u003c\/td\u003e\n\u003ctd\u003e1 micron, 1 ppm remaining oil\u003c\/td\u003e\n\u003ctd\u003ePrefilter ahead of a dryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003eDry particulate afterfilter\u003c\/td\u003e\n\u003ctd\u003e1 micron, outside-to-inside flow\u003c\/td\u003e\n\u003ctd\u003eAfterfilter on a heatless desiccant dryer to catch desiccant fines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eHigh efficiency oil removal coalescer\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.008 ppm remaining oil\u003c\/td\u003e\n\u003ctd\u003eAfter the dryer for instrument quality air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eMaximum efficiency oil removal coalescer\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.0008 ppm remaining oil\u003c\/td\u003e\n\u003ctd\u003eCritical process, food and pharmaceutical duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eActivated carbon oil vapor and odor removal\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.003 ppm remaining oil vapor\u003c\/td\u003e\n\u003ctd\u003eFinal polish downstream of a Grade E or F coalescer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e625, 1,000 and 1,250 SCFM\u003c\/strong\u003e: three vessel sizes covering large plant air headers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll Seven Champion Filter Grades\u003c\/strong\u003e: one housing platform, separator through activated carbon.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\" NPTM Connections\u003c\/strong\u003e: male pipe thread sized for main header tie-ins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e300 PSIG Maximum Working Pressure\u003c\/strong\u003e: full rating on all three 3-inch NPTM vessels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150°F Maximum Inlet Temperature\u003c\/strong\u003e: handles hot air off an aftercooler.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Gauge Standard\u003c\/strong\u003e: dual gauge face reads in either flow direction and tells you exactly when to change the element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Element Chamber\u003c\/strong\u003e: low face velocity, low clean pressure drop, long element life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Element Cores\u003c\/strong\u003e: corrosion resistant, silicone free, rated to 150°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Vessel Directive Compliant\u003c\/strong\u003e: housings conform to most major pressure vessel directives worldwide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChampion Pneumatic Quality\u003c\/strong\u003e: backed by over a century of compressed air engineering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eWelded pressure vessel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Flow Range\u003c\/td\u003e\n\u003ctd\u003e625 – 1,250 SCFM @ 100 PSIG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet \/ Outlet Connection\u003c\/td\u003e\n\u003ctd\u003e3\" NPTM (male)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Pressure\u003c\/td\u003e\n\u003ctd\u003e300 PSIG (21 kgf\/cm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inlet Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Grades Available\u003c\/td\u003e\n\u003ctd\u003eA, B, C, D, E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Pressure Indication\u003c\/td\u003e\n\u003ctd\u003eGauge, dual face, remote mounting available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain, 625 SCFM\u003c\/td\u003e\n\u003ctd\u003eInternal automatic drain available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain, 1,000 and 1,250 SCFM\u003c\/td\u003e\n\u003ctd\u003eDrain plugs standard, external automatic drains available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, 625 SCFM\u003c\/td\u003e\n\u003ctd\u003e40.88\" H x 10.25\" W (1,038 x 260 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, 1,000 and 1,250 SCFM\u003c\/td\u003e\n\u003ctd\u003e48.00\" H x 16.00\" W (1,219 x 406 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShip Weight\u003c\/td\u003e\n\u003ctd\u003e37 lb (625), 93 lb (1,000 and 1,250)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement Core\u003c\/td\u003e\n\u003ctd\u003eCorrosion resistant stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF.O.B. Shipping Point\u003c\/td\u003e\n\u003ctd\u003eOcala, FL 34474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eThese vessels belong on plant air systems in the 150 to 300 HP range and on any header carrying 600 SCFM or more: automotive assembly and paint shops, food and beverage plants, pharmaceutical and cleanroom utilities, plastics and injection molding, foundries, textile mills, glass plants, pulp and paper, and central compressor rooms feeding an entire facility. They are also the correct filtration to pair with the large end of the Champion dryer range, including \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xcnca-series-non-cycling-refrigerated-air-dryer\"\u003eXCNCA non-cycling refrigerated dryers\u003c\/a\u003e, \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xccya-series-cycling-refrigerated-air-dryer\"\u003eXCCYA cycling refrigerated dryers\u003c\/a\u003e, \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cdt-series-heatless-desiccant-air-dryer\"\u003eCDT heatless desiccant dryers\u003c\/a\u003e and \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-xchl-series-heatless-desiccant-air-dryer\"\u003eXCHL heatless desiccant dryers\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eBuild Your Filtration Train\u003c\/h2\u003e\u003cp\u003eA properly staged treatment train on a large system looks like this: a \u003cstrong\u003eGrade A mechanical separator\u003c\/strong\u003e or \u003cstrong\u003eGrade C particulate filter\u003c\/strong\u003e at the aftercooler discharge to knock out bulk water and pipe scale, then the \u003cstrong\u003edryer\u003c\/strong\u003e, then a \u003cstrong\u003eGrade E or Grade F coalescing filter\u003c\/strong\u003e to bring oil carryover down to instrument levels, and finally a \u003cstrong\u003eGrade G activated carbon filter\u003c\/strong\u003e where odor or oil vapor matters. On a heatless desiccant dryer, add a \u003cstrong\u003eGrade D afterfilter\u003c\/strong\u003e to capture desiccant fines. Never install a coalescing filter upstream of bulk water removal, because flooding a coalescer shortens its life dramatically.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually, or sooner if the differential pressure gauge shows a rise of 5 PSID above the clean reading. A clogged element wastes compressed air energy and eventually risks element collapse. The 625 and 1,250 SCFM vessels share a common element, the \u003cstrong\u003eCP\u003c\/strong\u003e series, while the 1,000 SCFM vessel uses the \u003cstrong\u003eC1000\u003c\/strong\u003e series. Both are stocked as \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cfl-series-pressure-vessel-replacement-filter-element\"\u003egenuine Champion replacement elements\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every CFL Series filter ships with the full factory warranty, lifetime application support, and access to our compressed air engineers for sizing and system design. If you are not sure whether your header calls for the 1,000 or the 1,250 SCFM vessel, send us your actual flow and pressure and we will size it for you.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow do these differ from the modular CFL housings?\u003c\/h3\u003e\u003cp\u003eThe modular housings, 20 through 780 SCFM, use a quarter-turn bayonet head and bowl with female NPTF ports. These are welded pressure vessels with 3\" NPTM male connections, a much larger element chamber, and a full 300 PSIG rating regardless of drain configuration.\u003c\/p\u003e\u003ch3\u003eCan I get an ASME U stamped vessel?\u003c\/h3\u003e\u003cp\u003eYes. The CFL configurator offers a U stamped vessel option in place of the standard non-coded construction. The models listed here are the standard non-coded build. Call us for an ASME coded quotation.\u003c\/p\u003e\u003ch3\u003eWhich element fits my vessel?\u003c\/h3\u003e\u003cp\u003eThe 625 and 1,250 SCFM vessels take the CP element for your grade, for example CPCE for Grade C. The 1,000 SCFM vessel takes the C1000 element, for example C1000CE. Both are listed on our pressure vessel element page.\u003c\/p\u003e\u003ch3\u003eDo I size by pipe size or by flow?\u003c\/h3\u003e\u003cp\u003eAlways by flow and operating pressure, never by pipe size. Champion publishes sizing correction factors for pressures other than 100 PSIG. If you are running at 125 PSIG your vessel will pass more air than the nameplate rating; at 80 PSIG it will pass less.\u003c\/p\u003e\u003ch3\u003eHow often does the drain need attention?\u003c\/h3\u003e\u003cp\u003eThe 625 SCFM vessel can be supplied with an internal automatic drain. The 1,000 and 1,250 SCFM vessels ship with drain plugs, so most installations add an external automatic or demand drain. We stock Champion CDV1 demand drains and timed electric drains.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"1000 SCFM (3\" NPTM) \/ Grade A: Mechanical Separator","offer_id":54788518478099,"sku":"CFL1000A27YTW","price":2673.0,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade A: Mechanical Separator","offer_id":54788518510867,"sku":"CFL1250A27YTW","price":2770.2,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade B: Separator\/Filter 3 Micron","offer_id":54788518543635,"sku":"CFL625B27GYTW","price":3264.3,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade B: Separator\/Filter 3 Micron","offer_id":54788518576403,"sku":"CFL1000B27GYTW","price":3142.8,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade B: Separator\/Filter 3 Micron","offer_id":54788518609171,"sku":"CFL1250B27GYTW","price":3272.4,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade C: Air Line Filter 1 Micron","offer_id":54788518641939,"sku":"CFL625C27AGYTW","price":2948.4,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade C: Air Line Filter 1 Micron","offer_id":54788518674707,"sku":"CFL1000C27GYTW","price":2664.9,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade C: Air Line Filter 1 Micron","offer_id":54788518707475,"sku":"CFL1250C27GYTW","price":2754.0,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade D: Dry Particulate Afterfilter","offer_id":54788518740243,"sku":"CFL625D27GYTW","price":2972.7,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade D: Dry Particulate Afterfilter","offer_id":54788518773011,"sku":"CFL1000D27GYTW","price":2754.0,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade D: Dry Particulate Afterfilter","offer_id":54788518805779,"sku":"CFL1250D27GYTW","price":2835.0,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade E: High Efficiency Oil Removal","offer_id":54788518838547,"sku":"CFL625E27AYTW","price":3159.0,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade E: High Efficiency Oil Removal","offer_id":54788518871315,"sku":"CFL1000E27GYTW","price":3013.2,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade E: High Efficiency Oil Removal","offer_id":54788518904083,"sku":"CFL1250E27GYTW","price":3094.2,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade F: Maximum Efficiency Oil Removal","offer_id":54788518936851,"sku":"CFL625F27AYTW","price":3191.4,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade F: Maximum Efficiency Oil Removal","offer_id":54788518969619,"sku":"CFL1000F27GYTW","price":3110.4,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade F: Maximum Efficiency Oil Removal","offer_id":54788519002387,"sku":"CFL1250F27GYTW","price":3159.0,"currency_code":"USD","in_stock":true},{"title":"625 SCFM (3\" NPTM) \/ Grade G: Oil Vapor Removal Carbon","offer_id":54788519035155,"sku":"CFL625G27YTW","price":2600.1,"currency_code":"USD","in_stock":true},{"title":"1000 SCFM (3\" NPTM) \/ Grade G: Oil Vapor Removal Carbon","offer_id":54788519067923,"sku":"CFL1000G27YTW","price":3061.8,"currency_code":"USD","in_stock":true},{"title":"1250 SCFM (3\" NPTM) \/ Grade G: Oil Vapor Removal Carbon","offer_id":54788519100691,"sku":"CFL1250G27YTW","price":3110.4,"currency_code":"USD","in_stock":true}]},{"product_id":"champion-cfl-series-pressure-vessel-replacement-filter-element","title":"Champion CFL Series Replacement Filter Element – Pressure Vessel Housings, Grades A–G (625–1,250 SCFM)","description":"\u003cp\u003eGenuine Champion replacement filter elements for the \u003cstrong\u003eCFL Series pressure vessel housings\u003c\/strong\u003e rated 625, 1,000 and 1,250 SCFM. Every one of the seven Champion filter grades is covered, from the Grade A mechanical separator through the Grade G activated carbon oil vapor element.\u003c\/p\u003e\u003cp\u003eThese are the large-vessel elements, not the modular 20 to 780 SCFM elements. If your housing has a quarter-turn bayonet head and female NPTF ports, you need a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filter-elements\"\u003emodular CFL element\u003c\/a\u003e instead. If it is a welded vessel with 3-inch NPTM male connections, you are in the right place.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your filter grade and housing size from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eWhich Element Fits Your Housing\u003c\/h2\u003e\u003cp\u003eThe 625 and 1,250 SCFM vessels share a common element, designated \u003cstrong\u003eCP\u003c\/strong\u003e plus the grade letter plus E. The 1,000 SCFM vessel uses a different element, designated \u003cstrong\u003eC1000\u003c\/strong\u003e plus the grade letter plus E. Match the grade letter in your housing model number to the grade letter in the element part number.\u003c\/p\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement P\/N\u003c\/th\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eFits Housing\u003c\/th\u003e\n\u003cth\u003eFiltration Performance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPAE\u003c\/td\u003e\n\u003ctd\u003eGrade A\u003c\/td\u003e\n\u003ctd\u003e625 and 1250 SCFM\u003c\/td\u003e\n\u003ctd\u003eMechanical water separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1000AE\u003c\/td\u003e\n\u003ctd\u003eGrade A\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003eMechanical water separation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPBE\u003c\/td\u003e\n\u003ctd\u003eGrade B\u003c\/td\u003e\n\u003ctd\u003e625 and 1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e3 micron, 5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1000BE\u003c\/td\u003e\n\u003ctd\u003eGrade B\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e3 micron, 5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPCE\u003c\/td\u003e\n\u003ctd\u003eGrade C\u003c\/td\u003e\n\u003ctd\u003e625 and 1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1 micron, 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1000CE\u003c\/td\u003e\n\u003ctd\u003eGrade C\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e1 micron, 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPDE\u003c\/td\u003e\n\u003ctd\u003eGrade D\u003c\/td\u003e\n\u003ctd\u003e625 and 1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e1 micron dry particulate, outside-to-inside flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1000DE\u003c\/td\u003e\n\u003ctd\u003eGrade D\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e1 micron dry particulate, outside-to-inside flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPEE\u003c\/td\u003e\n\u003ctd\u003eGrade E\u003c\/td\u003e\n\u003ctd\u003e625 and 1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.008 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1000EE\u003c\/td\u003e\n\u003ctd\u003eGrade E\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.008 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPFE\u003c\/td\u003e\n\u003ctd\u003eGrade F\u003c\/td\u003e\n\u003ctd\u003e625 and 1250 SCFM\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.0008 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1000FE\u003c\/td\u003e\n\u003ctd\u003eGrade F\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003e0.01 micron, 0.0008 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPGE\u003c\/td\u003e\n\u003ctd\u003eGrade G\u003c\/td\u003e\n\u003ctd\u003e625 and 1250 SCFM\u003c\/td\u003e\n\u003ctd\u003eActivated carbon, 0.003 ppm oil vapor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1000GE\u003c\/td\u003e\n\u003ctd\u003eGrade G\u003c\/td\u003e\n\u003ctd\u003e1000 SCFM\u003c\/td\u003e\n\u003ctd\u003eActivated carbon, 0.003 ppm oil vapor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eHousing to Element Cross Reference\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing Model\u003c\/th\u003e\n\u003cth\u003eRated Flow\u003c\/th\u003e\n\u003cth\u003eElement for Grades A \/ B \/ C \/ D \/ E \/ F \/ G\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL625_27\u003c\/td\u003e\n\u003ctd\u003e625 SCFM\u003c\/td\u003e\n\u003ctd\u003eCPAE \/ CPBE \/ CPCE \/ CPDE \/ CPEE \/ CPFE \/ CPGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1000_27\u003c\/td\u003e\n\u003ctd\u003e1,000 SCFM\u003c\/td\u003e\n\u003ctd\u003eC1000AE \/ C1000BE \/ C1000CE \/ C1000DE \/ C1000EE \/ C1000FE \/ C1000GE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFL1250_27\u003c\/td\u003e\n\u003ctd\u003e1,250 SCFM\u003c\/td\u003e\n\u003ctd\u003eCPAE \/ CPBE \/ CPCE \/ CPDE \/ CPEE \/ CPFE \/ CPGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eKey Features at a Glance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenuine Champion Parts\u003c\/strong\u003e: engineered for the CFL vessel, not a generic crossover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll Seven Grades\u003c\/strong\u003e: separator, general purpose, particulate, desiccant afterfilter, high efficiency and maximum efficiency coalescing, and activated carbon.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Effective Surface Area\u003c\/strong\u003e: high capture rate with low pressure drop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion Resistant Stainless Steel Cores\u003c\/strong\u003e: hold shape under full differential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSilicone Free\u003c\/strong\u003e: safe for paint and coating applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated to 150°F (66°C)\u003c\/strong\u003e: matches the housing temperature limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor Coded\u003c\/strong\u003e: grade identification at a glance during service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePush-On Design\u003c\/strong\u003e: quick element change with no special tools.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eChampion CFL Series pressure vessel housings, 625 \/ 1,000 \/ 1,250 SCFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrades Available\u003c\/td\u003e\n\u003ctd\u003eA, B, C, D, E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F (66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Material\u003c\/td\u003e\n\u003ctd\u003eCorrosion resistant stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Direction\u003c\/td\u003e\n\u003ctd\u003eInside-to-outside (Grade D is outside-to-inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicone Content\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Change Interval\u003c\/td\u003e\n\u003ctd\u003eAnnually, or at 5 PSID above clean differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF.O.B. Shipping Point\u003c\/td\u003e\n\u003ctd\u003eOcala, FL 34474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhen to Change the Element\u003c\/h2\u003e\u003cp\u003eChange the element once a year, or sooner if the differential pressure gauge on the housing reads 5 PSID above the clean value. Running past that point is expensive: every PSID of pressure drop costs roughly one percent of your compressor horsepower, so a neglected element on a 200 HP plant air system quietly burns real money every shift. On coalescing grades E and F the element also loses efficiency as it loads, so oil carryover climbs downstream before the pressure drop tells you anything. Activated carbon Grade G elements have no useful differential pressure signature at all and should be changed on a strict calendar interval, typically every six to twelve months depending on inlet oil load.\u003c\/p\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eScheduled maintenance on large plant air systems in automotive, food and beverage, pharmaceutical, plastics, foundry, textile, glass and pulp and paper facilities, and on any central compressor room running a CFL pressure vessel in the filtration train ahead of or behind a large refrigerated or desiccant dryer.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. These are genuine factory elements, not aftermarket lookalikes, and they carry the Champion warranty. If you are not sure which grade is in your housing, send us the model number off the nameplate and we will identify the correct element.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eMy housing is a CFL1000CG. Which element do I order?\u003c\/h3\u003e\u003cp\u003eThe grade letter is C and the vessel is the 1,000 SCFM size, so you need C1000CE. Select Grade C and the 1000 SCFM housing option above.\u003c\/p\u003e\u003ch3\u003eWhy do the 625 and 1,250 SCFM vessels use the same element?\u003c\/h3\u003e\u003cp\u003eThe two vessels use a common element cartridge. The 1,250 SCFM vessel is the larger body of the two but Champion specifies the same CP element for both. The 1,000 SCFM vessel is the odd one out and takes the C1000 element.\u003c\/p\u003e\u003ch3\u003eCan I put a higher grade element in my housing?\u003c\/h3\u003e\u003cp\u003eNo. The housing and element are matched as a set, and fitting a finer element than the housing was configured for will drive pressure drop up without giving you the rated performance. Change the grade at the housing level, not at the element.\u003c\/p\u003e\u003ch3\u003eDo I need to replace the o-rings too?\u003c\/h3\u003e\u003cp\u003eInspect the head seal at every element change. Champion supplies the required seals with the element on most grades. If yours is damaged or hardened, call us and we will send the seal kit.\u003c\/p\u003e\u003ch3\u003eHow long does shipping take?\u003c\/h3\u003e\u003cp\u003eElements ship from Ocala, Florida. Call us for current lead time on your grade and size.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"Grade A: Mechanical Separator \/ Fits 625 \u0026 1250 SCFM Housings","offer_id":54788538859795,"sku":"CPAE","price":201.69,"currency_code":"USD","in_stock":true},{"title":"Grade A: Mechanical Separator \/ Fits 1000 SCFM Housings","offer_id":54788538892563,"sku":"C1000AE","price":274.59,"currency_code":"USD","in_stock":true},{"title":"Grade B: Separator\/Filter 3 Micron \/ Fits 625 \u0026 1250 SCFM Housings","offer_id":54788538925331,"sku":"CPBE","price":498.96,"currency_code":"USD","in_stock":true},{"title":"Grade B: Separator\/Filter 3 Micron \/ Fits 1000 SCFM Housings","offer_id":54788538958099,"sku":"C1000BE","price":514.35,"currency_code":"USD","in_stock":true},{"title":"Grade C: Air Line Filter 1 Micron \/ Fits 625 \u0026 1250 SCFM Housings","offer_id":54788538990867,"sku":"CPCE","price":288.36,"currency_code":"USD","in_stock":true},{"title":"Grade C: Air Line Filter 1 Micron \/ Fits 1000 SCFM Housings","offer_id":54788539023635,"sku":"C1000CE","price":227.61,"currency_code":"USD","in_stock":true},{"title":"Grade D: Dry Particulate Afterfilter \/ Fits 625 \u0026 1250 SCFM Housings","offer_id":54788539056403,"sku":"CPDE","price":274.59,"currency_code":"USD","in_stock":true},{"title":"Grade D: Dry Particulate Afterfilter \/ Fits 1000 SCFM Housings","offer_id":54788539089171,"sku":"C1000DE","price":270.54,"currency_code":"USD","in_stock":true},{"title":"Grade E: High Efficiency Oil Removal \/ Fits 625 \u0026 1250 SCFM Housings","offer_id":54788539121939,"sku":"CPEE","price":460.89,"currency_code":"USD","in_stock":true},{"title":"Grade E: High Efficiency Oil Removal \/ Fits 1000 SCFM Housings","offer_id":54788539154707,"sku":"C1000EE","price":339.39,"currency_code":"USD","in_stock":true},{"title":"Grade F: Maximum Efficiency Oil Removal \/ Fits 625 \u0026 1250 SCFM Housings","offer_id":54788539187475,"sku":"CPFE","price":498.15,"currency_code":"USD","in_stock":true},{"title":"Grade F: Maximum Efficiency Oil Removal \/ Fits 1000 SCFM Housings","offer_id":54788539220243,"sku":"C1000FE","price":440.64,"currency_code":"USD","in_stock":true},{"title":"Grade G: Oil Vapor Removal Carbon \/ Fits 625 \u0026 1250 SCFM Housings","offer_id":54788539253011,"sku":"CPGE","price":520.83,"currency_code":"USD","in_stock":true},{"title":"Grade G: Oil Vapor Removal Carbon \/ Fits 1000 SCFM Housings","offer_id":54788539285779,"sku":"C1000GE","price":504.63,"currency_code":"USD","in_stock":true}]},{"product_id":"champion-frl-series-modular-compressed-air-filter","title":"Champion FRL Series Modular Compressed Air Filter – Particulate, Coalescing \u0026 Carbon (1\/4\" to 1\" NPT)","description":"\u003cp\u003eThe \u003cstrong\u003eChampion FRL Series\u003c\/strong\u003e is Champion Pneumatic's modular air preparation line: compact \u003cstrong\u003epoint-of-use filters\u003c\/strong\u003e that mount right at the machine, the tool drop or the panel inlet. This listing covers all four filtration grades across seven body-and-port combinations from \u003cstrong\u003e1\/4\" through 1\" NPT\u003c\/strong\u003e. Every unit uses a quick-disconnect metal bowl with a sight gauge and a safety warning latch, and every body shares the same modular face, so filters, regulators and lubricators bolt together into a complete FRL station without adapters.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSelect your body size and filtration grade from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eFour Filtration Grades on One Body\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 Micron Particulate (CF Series):\u003c\/strong\u003e The standard general-purpose stage. A turbine-shaped upper baffle spins incoming air to throw out bulk liquid and heavy particles mechanically, a quiet-zone baffle keeps the collected condensate from being re-entrained, and depth-filtration media catches solids down to 5 micron at very low pressure drop. Rated to 200 psig.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.5 Micron Coalescing (CM Series, S element):\u003c\/strong\u003e Coalesces oil aerosols and water mist into droplets that drain away, and removes solids to 0.5 micron. The right choice ahead of air motors, cylinders and general spray work. Rated to 150 psig.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.01 Micron Coalescing (CM Series, T element):\u003c\/strong\u003e High-efficiency coalescing for instrument-quality air. Removes submicron oil aerosol and particulate down to 0.01 micron. Use it ahead of precision instruments, electronics assembly and critical paint work. Rated to 150 psig.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarbon Vapor \/ Odor Removal (CM Series, X element):\u003c\/strong\u003e An activated-carbon bed that adsorbs the oil vapour and hydrocarbon odour that coalescing filters cannot catch. Always install it downstream of a 0.01 micron coalescing filter, never on raw compressor air. Rated to 150 psig.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003ePort\u003c\/th\u003e\n\u003cth\u003eMax Flow\u003c\/th\u003e\n\u003cth\u003eNominal Flow\u003c\/th\u003e\n\u003cth\u003eW x H\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF03-02-M00\u003c\/td\u003e\n\u003ctd\u003e5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e16 SCFM\u003c\/td\u003e\n\u003ctd\u003e1.5 x 3.6 in\u003c\/td\u003e\n\u003ctd\u003e0.4 lb\u003c\/td\u003e\n\u003ctd\u003eCFRP-95-235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF16-02-G00\u003c\/td\u003e\n\u003ctd\u003e5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e63 SCFM\u003c\/td\u003e\n\u003ctd\u003e30 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 7.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCFRP-95-160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF16-03-G00\u003c\/td\u003e\n\u003ctd\u003e5 Micron\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e74 SCFM\u003c\/td\u003e\n\u003ctd\u003e35 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 7.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCFRP-95-160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF16-04-G00\u003c\/td\u003e\n\u003ctd\u003e5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e80 SCFM\u003c\/td\u003e\n\u003ctd\u003e40 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 7.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCFRP-95-160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF26-04-G00\u003c\/td\u003e\n\u003ctd\u003e5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e150 SCFM\u003c\/td\u003e\n\u003ctd\u003e70 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.3 x 7.3 in\u003c\/td\u003e\n\u003ctd\u003e3 lb\u003c\/td\u003e\n\u003ctd\u003eCFRP-95-115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF30-06-G00\u003c\/td\u003e\n\u003ctd\u003e5 Micron\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e323 SCFM\u003c\/td\u003e\n\u003ctd\u003e140 SCFM\u003c\/td\u003e\n\u003ctd\u003e4.6 x 9.8 in\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003ctd\u003eCFRP-95-209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCF30-08-G00\u003c\/td\u003e\n\u003ctd\u003e5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e316 SCFM\u003c\/td\u003e\n\u003ctd\u003e160 SCFM\u003c\/td\u003e\n\u003ctd\u003e4.6 x 9.8 in\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003ctd\u003eCFRP-95-209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM03-02-MS0\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e9 SCFM\u003c\/td\u003e\n\u003ctd\u003e1.5 x 3.6 in\u003c\/td\u003e\n\u003ctd\u003e0.4 lb\u003c\/td\u003e\n\u003ctd\u003eCMSP-95-991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM16-02-GS0\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e37 SCFM\u003c\/td\u003e\n\u003ctd\u003e18 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 8.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCMSP-95-988\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM16-03-GS0\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 SCFM\u003c\/td\u003e\n\u003ctd\u003e21 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 8.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCMSP-95-988\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM16-04-GS0\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e48 SCFM\u003c\/td\u003e\n\u003ctd\u003e22 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 8.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCMSP-95-988\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM26-04-GS0\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e80 SCFM\u003c\/td\u003e\n\u003ctd\u003e37 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.3 x 8.2 in\u003c\/td\u003e\n\u003ctd\u003e3 lb\u003c\/td\u003e\n\u003ctd\u003eCMSP-95-989\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM30-06-GS0\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e173 SCFM\u003c\/td\u003e\n\u003ctd\u003e85 SCFM\u003c\/td\u003e\n\u003ctd\u003e4.6 x 10.5 in\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003ctd\u003eCMSP-95-992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM30-08-GS0\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e203 SCFM\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e4.6 x 10.5 in\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003ctd\u003eCMSP-95-992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM16-02-G00\u003c\/td\u003e\n\u003ctd\u003e0.01 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e37 SCFM\u003c\/td\u003e\n\u003ctd\u003e18 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 8.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCMTP-95-548\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM16-03-G00\u003c\/td\u003e\n\u003ctd\u003e0.01 Micron\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 SCFM\u003c\/td\u003e\n\u003ctd\u003e21 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 8.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCMTP-95-548\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM16-04-G00\u003c\/td\u003e\n\u003ctd\u003e0.01 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e48 SCFM\u003c\/td\u003e\n\u003ctd\u003e22 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.0 x 8.1 in\u003c\/td\u003e\n\u003ctd\u003e2 lb\u003c\/td\u003e\n\u003ctd\u003eCMTP-95-548\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM26-04-G00\u003c\/td\u003e\n\u003ctd\u003e0.01 Micron\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e80 SCFM\u003c\/td\u003e\n\u003ctd\u003e37 SCFM\u003c\/td\u003e\n\u003ctd\u003e3.3 x 8.2 in\u003c\/td\u003e\n\u003ctd\u003e3 lb\u003c\/td\u003e\n\u003ctd\u003eCMTP-95-548\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM30-06-G00\u003c\/td\u003e\n\u003ctd\u003e0.01 Micron\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e173 SCFM\u003c\/td\u003e\n\u003ctd\u003e85 SCFM\u003c\/td\u003e\n\u003ctd\u003e4.6 x 10.5 in\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003ctd\u003eCMTP-95-551\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM30-08-G00\u003c\/td\u003e\n\u003ctd\u003e0.01 Micron\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e203 SCFM\u003c\/td\u003e\n\u003ctd\u003e100 SCFM\u003c\/td\u003e\n\u003ctd\u003e4.6 x 10.5 in\u003c\/td\u003e\n\u003ctd\u003e6 lb\u003c\/td\u003e\n\u003ctd\u003eCMTP-95-551\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM03-02-MX0\u003c\/td\u003e\n\u003ctd\u003eCarbon\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e20 SCFM\u003c\/td\u003e\n\u003ctd\u003e9 SCFM\u003c\/td\u003e\n\u003ctd\u003e1.5 x 3.6 in\u003c\/td\u003e\n\u003ctd\u003e0.4 lb\u003c\/td\u003e\n\u003ctd\u003eCMXP-95-054\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick-disconnect metal bowl:\u003c\/strong\u003e Bayonet-style bowl with a sight gauge and a safety warning latch that vents residual pressure before the bowl can be removed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular face:\u003c\/strong\u003e Filters, regulators and lubricators in the same body series connect directly to one another using modular sleeves, so a two or three stage FRL station needs no pipe nipples between units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual drain standard:\u003c\/strong\u003e Automatic mechanical drain available as a field-fitted option on the 16, 26 and 30 Series, and as a piston drain on the 03 Series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour grades, one footprint:\u003c\/strong\u003e Swap filtration class without redesigning the piping run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix body sizes:\u003c\/strong\u003e 03, 16, 26, 30 Series covering 1\/4\" through 1\" NPT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-replaceable element:\u003c\/strong\u003e A yearly element change keeps the housing in service indefinitely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow pressure drop:\u003c\/strong\u003e Depth-filtration media sized so a correctly selected filter costs you very little compressed-air energy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChampion Pneumatic quality:\u003c\/strong\u003e Backed by over a century of compressed-air engineering.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltration Grades\u003c\/td\u003e\n\u003ctd\u003e5 micron particulate, 0.5 micron coalescing, 0.01 micron coalescing, activated carbon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Sizes\u003c\/td\u003e\n\u003ctd\u003e1\/4\", 3\/8\", 1\/2\", 3\/4\", 1\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure, 5 Micron Particulate\u003c\/td\u003e\n\u003ctd\u003e200 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure, Coalescing and Carbon\u003c\/td\u003e\n\u003ctd\u003e150 psig\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd\u003e150°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBowl\u003c\/td\u003e\n\u003ctd\u003eMetal with sight gauge, quick-disconnect with safety warning latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eManual standard, automatic mechanical drain optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticulate Max Flow Basis\u003c\/td\u003e\n\u003ctd\u003e150 psig inlet, 5 psid pressure drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticulate Nominal Flow Basis\u003c\/td\u003e\n\u003ctd\u003e100 psig inlet, 1.5 psid pressure drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoalescing Max Flow Basis\u003c\/td\u003e\n\u003ctd\u003e150 psig inlet, 3 psid pressure drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoalescing Nominal Flow Basis\u003c\/td\u003e\n\u003ctd\u003e100 psig inlet, 1.5 psid pressure drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eMax Flow or Nominal Flow: Which Do I Size To?\u003c\/h2\u003e\u003cp\u003eSize to the \u003cstrong\u003enominal flow\u003c\/strong\u003e figure. Max flow is what the filter will pass before pressure drop becomes unacceptable, measured at a 5 psid (particulate) or 3 psid (coalescing) drop. Nominal flow is measured at 1.5 psid and is the flow at which the filter runs efficiently and the element lasts. Sizing to max flow means you are paying for that pressure drop in compressor energy every hour the machine runs, roughly 1% of compressor horsepower per psid. When a drop sits between two sizes, go up.\u003c\/p\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003ePoint-of-use filtration at machine inlets, tool drops, air-motor feeds and pneumatic control panels. Typical installs include CNC and machining-centre air supply, packaging and bottling lines, automated assembly cells, spray and paint-prep stations, laboratory benches, dental and medical air drops, air-motor and actuator protection, and blow-off and part-ejection stations. On larger plant-air headers, use the inline \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filters\"\u003eChampion CFL and XC Series filters\u003c\/a\u003e at the compressor room and reserve the FRL Series for the last few feet before the machine.\u003c\/p\u003e\u003ch2\u003eBuilding a Complete FRL Station\u003c\/h2\u003e\u003cp\u003eA full Champion air-preparation station is built left to right in the direction of flow: \u003cstrong\u003efilter\u003c\/strong\u003e, then \u003cstrong\u003eregulator\u003c\/strong\u003e, then \u003cstrong\u003elubricator\u003c\/strong\u003e. Pair this filter with a \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cr-series-compressed-air-pressure-regulator\"\u003eChampion CR Series regulator\u003c\/a\u003e and a \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-cl-series-compressed-air-line-lubricator\"\u003eChampion CL Series lubricator\u003c\/a\u003e in the matching body series. Where a filter and regulator alone will do, the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-ccb6-series-integral-filter-regulator\"\u003eChampion CCB6 integral filter regulator\u003c\/a\u003e puts both functions in a single body. Modular sleeves, manifold blocks, 3-way shut-off valves, drains and gauges are listed under \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-frl-series-modular-accessories\"\u003eChampion FRL Series modular accessories\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eElement Replacement and Service\u003c\/h2\u003e\u003cp\u003eReplace the element annually, or sooner if pressure drop across the filter climbs noticeably, whichever comes first. Coalescing and carbon elements are consumables and should be changed on schedule rather than on appearance, because a saturated coalescing element passes the very contaminant it was installed to catch and a spent carbon bed can release adsorbed hydrocarbon downstream. Matching \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-frl-series-replacement-filter-element\"\u003eChampion FRL Series replacement elements\u003c\/a\u003e are listed separately; the model selection chart above gives the correct element part number for each filter.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. Every FRL Series filter ships with the full factory warranty, lifetime application support, and access to our compressed-air engineers for sizing and system design.\u003c\/p\u003e\u003ch2\u003eAlso Available by Quote\u003c\/h2\u003e\u003cp\u003eChampion prices two models in this family on a consult-factory basis, so they are not listed for direct purchase: \u003cstrong\u003eCM03-02-M00\u003c\/strong\u003e (03 Series, 1\/4\", 0.01 micron) and the carbon vapour-removal models \u003cstrong\u003eCM16-02-GX0\u003c\/strong\u003e, \u003cstrong\u003eCM16-03-GX0\u003c\/strong\u003e, \u003cstrong\u003eCM16-04-GX0\u003c\/strong\u003e, \u003cstrong\u003eCM26-04-GX0\u003c\/strong\u003e, \u003cstrong\u003eCM30-06-GX0\u003c\/strong\u003e and \u003cstrong\u003eCM30-08-GX0\u003c\/strong\u003e. Call us for current pricing and lead time on any of these.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between the 5 micron, 0.5 micron and 0.01 micron grades?\u003c\/h3\u003e\u003cp\u003eThey are different jobs, not just different tightness. The 5 micron particulate filter removes solid debris and bulk liquid water mechanically. The 0.5 and 0.01 micron units are coalescing filters: they capture oil aerosol and water mist by merging fine droplets into large ones that drain out. Coalescing filters clog quickly if you feed them raw, dirty air, so a 5 micron particulate filter always goes upstream of one.\u003c\/p\u003e\u003ch3\u003eDo I need the carbon filter?\u003c\/h3\u003e\u003cp\u003eOnly if oil vapour or odour matters to your process, for example breathing-quality air, food contact, or paint where a fisheye is a scrap part. Carbon adsorbs vapour-phase hydrocarbon that no coalescing filter can catch. It must be installed downstream of a 0.01 micron coalescing filter, because liquid oil will blind a carbon bed in days.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the 03, 16, 26 and 30 Series bodies?\u003c\/h3\u003e\u003cp\u003eBody size, and therefore flow capacity and element size. The 03 Series is a compact 1\/4\" unit for small drops. The 16 Series is the general-purpose workhorse in 1\/4\", 3\/8\" and 1\/2\". The 26 Series is a higher-flow 1\/2\". The 30 Series covers 3\/4\" and 1\". Modular accessories are shared across the 16 and 26 Series.\u003c\/p\u003e\u003ch3\u003eDoes the filter come with an automatic drain?\u003c\/h3\u003e\u003cp\u003eManual drain is standard. An internal automatic mechanical drain is available as an option: the float drain for the 16, 26 and 30 Series and the piston drain for the 03 Series. Both are listed under our Champion FRL Series modular accessories.\u003c\/p\u003e\u003ch3\u003eCan I mount these to a wall?\u003c\/h3\u003e\u003cp\u003eYes. Modular sleeves with a wall-mount T-bracket are available and are listed under Champion FRL Series modular accessories.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"03 Series - 1\/4\" NPT \/ 5 Micron Particulate","offer_id":67531325800723,"sku":"CF03-02-M00","price":120.69,"currency_code":"USD","in_stock":true},{"title":"16 Series - 1\/4\" NPT \/ 5 Micron Particulate","offer_id":67531325833491,"sku":"CF16-02-G00","price":140.94,"currency_code":"USD","in_stock":true},{"title":"16 Series - 3\/8\" NPT \/ 5 Micron Particulate","offer_id":67531325866259,"sku":"CF16-03-G00","price":98.01,"currency_code":"USD","in_stock":true},{"title":"16 Series - 1\/2\" NPT \/ 5 Micron Particulate","offer_id":67531325899027,"sku":"CF16-04-G00","price":144.99,"currency_code":"USD","in_stock":true},{"title":"26 Series - 1\/2\" NPT \/ 5 Micron Particulate","offer_id":67531325931795,"sku":"CF26-04-G00","price":164.43,"currency_code":"USD","in_stock":true},{"title":"30 Series - 3\/4\" NPT \/ 5 Micron Particulate","offer_id":67531325964563,"sku":"CF30-06-G00","price":249.48,"currency_code":"USD","in_stock":true},{"title":"30 Series - 1\" NPT \/ 5 Micron Particulate","offer_id":67531325997331,"sku":"CF30-08-G00","price":272.97,"currency_code":"USD","in_stock":true},{"title":"03 Series - 1\/4\" NPT \/ 0.5 Micron Coalescing","offer_id":67531326030099,"sku":"CM03-02-MS0","price":154.71,"currency_code":"USD","in_stock":true},{"title":"16 Series - 1\/4\" NPT \/ 0.5 Micron Coalescing","offer_id":67531326062867,"sku":"CM16-02-GS0","price":184.68,"currency_code":"USD","in_stock":true},{"title":"16 Series - 3\/8\" NPT \/ 0.5 Micron Coalescing","offer_id":67531326095635,"sku":"CM16-03-GS0","price":173.34,"currency_code":"USD","in_stock":true},{"title":"16 Series - 1\/2\" NPT \/ 0.5 Micron Coalescing","offer_id":67531326128403,"sku":"CM16-04-GS0","price":170.91,"currency_code":"USD","in_stock":true},{"title":"26 Series - 1\/2\" NPT \/ 0.5 Micron Coalescing","offer_id":67531326161171,"sku":"CM26-04-GS0","price":225.18,"currency_code":"USD","in_stock":true},{"title":"30 Series - 3\/4\" NPT \/ 0.5 Micron Coalescing","offer_id":67531326193939,"sku":"CM30-06-GS0","price":431.73,"currency_code":"USD","in_stock":true},{"title":"30 Series - 1\" NPT \/ 0.5 Micron Coalescing","offer_id":67531326226707,"sku":"CM30-08-GS0","price":431.73,"currency_code":"USD","in_stock":true},{"title":"16 Series - 1\/4\" NPT \/ 0.01 Micron Coalescing","offer_id":67531326259475,"sku":"CM16-02-G00","price":181.44,"currency_code":"USD","in_stock":true},{"title":"16 Series - 3\/8\" NPT \/ 0.01 Micron Coalescing","offer_id":67531326292243,"sku":"CM16-03-G00","price":179.01,"currency_code":"USD","in_stock":true},{"title":"16 Series - 1\/2\" NPT \/ 0.01 Micron Coalescing","offer_id":67531326325011,"sku":"CM16-04-G00","price":230.85,"currency_code":"USD","in_stock":true},{"title":"26 Series - 1\/2\" NPT \/ 0.01 Micron Coalescing","offer_id":67531326357779,"sku":"CM26-04-G00","price":298.89,"currency_code":"USD","in_stock":true},{"title":"30 Series - 3\/4\" NPT \/ 0.01 Micron Coalescing","offer_id":67531326390547,"sku":"CM30-06-G00","price":464.94,"currency_code":"USD","in_stock":true},{"title":"30 Series - 1\" NPT \/ 0.01 Micron Coalescing","offer_id":67531326423315,"sku":"CM30-08-G00","price":504.63,"currency_code":"USD","in_stock":true},{"title":"03 Series - 1\/4\" NPT \/ Carbon Vapor \/ Odor Removal","offer_id":67531326456083,"sku":"CM03-02-MX0","price":370.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/champion-frl-particulate-coalescing-filter.jpg?v=1790508059"},{"product_id":"champion-frl-series-replacement-filter-element","title":"Champion FRL Series Replacement Filter Element – Particulate, Coalescing \u0026 Carbon","description":"\u003cp\u003eGenuine \u003cstrong\u003eChampion replacement filter elements\u003c\/strong\u003e for the FRL Series modular point-of-use filters. This listing covers all four filtration grades across the 03, 16, 26 and 30 Series bodies. Every element is a direct factory replacement: no adapters, no aftermarket fitment guessing, and no risk of a loose element bypassing unfiltered air around the seal.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFind your element part number in the cross-reference chart below, then select it from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eFilter to Element Cross-Reference\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eFits Filter Models\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFRP-95-235\u003c\/td\u003e\n\u003ctd\u003e5 Micron Particulate\u003c\/td\u003e\n\u003ctd\u003eCF03-02-M00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFRP-95-160\u003c\/td\u003e\n\u003ctd\u003e5 Micron Particulate\u003c\/td\u003e\n\u003ctd\u003eCF16-02-G00, CF16-03-G00, CF16-04-G00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFRP-95-115\u003c\/td\u003e\n\u003ctd\u003e5 Micron Particulate\u003c\/td\u003e\n\u003ctd\u003eCF26-04-G00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCFRP-95-209\u003c\/td\u003e\n\u003ctd\u003e5 Micron Particulate\u003c\/td\u003e\n\u003ctd\u003eCF30-06-G00, CF30-08-G00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMSP-95-988\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron Coalescing\u003c\/td\u003e\n\u003ctd\u003eCM16-02-GS0, CM16-03-GS0, CM16-04-GS0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMSP-95-989\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron Coalescing\u003c\/td\u003e\n\u003ctd\u003eCM26-04-GS0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMSP-95-992\u003c\/td\u003e\n\u003ctd\u003e0.5 Micron Coalescing\u003c\/td\u003e\n\u003ctd\u003eCM30-06-GS0, CM30-08-GS0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMTP-95-548\u003c\/td\u003e\n\u003ctd\u003e0.01 Micron Coalescing\u003c\/td\u003e\n\u003ctd\u003eCM16-02-G00, CM16-03-G00, CM16-04-G00, CM26-04-G00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMTP-95-551\u003c\/td\u003e\n\u003ctd\u003e0.01 Micron Coalescing\u003c\/td\u003e\n\u003ctd\u003eCM30-06-G00, CM30-08-G00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMXP-95-987\u003c\/td\u003e\n\u003ctd\u003eCarbon Vapor \/ Odor Removal\u003c\/td\u003e\n\u003ctd\u003eCM16-02-GX0, CM16-03-GX0, CM16-04-GX0, CM26-04-GX0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eHow to Read the Part Number\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCFRP:\u003c\/strong\u003e 5 micron particulate element for a CF Series filter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMSP:\u003c\/strong\u003e 0.5 micron coalescing element for a CM Series filter (the S grade).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMTP:\u003c\/strong\u003e 0.01 micron coalescing element for a CM Series filter (the T grade).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMXP:\u003c\/strong\u003e Activated carbon vapor and odor removal element for a CM Series filter (the X grade).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eWhen to Change Each Grade\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eService Interval\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 Micron Particulate\u003c\/td\u003e\n\u003ctd\u003eAnnually, or when pressure drop rises\u003c\/td\u003e\n\u003ctd\u003eA loaded depth element costs energy in pressure drop long before it fails.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5 and 0.01 Micron Coalescing\u003c\/td\u003e\n\u003ctd\u003eAnnually, on schedule\u003c\/td\u003e\n\u003ctd\u003eA saturated coalescing element passes the oil aerosol it was fitted to catch, and it will look perfectly normal while doing so.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Vapor \/ Odor\u003c\/td\u003e\n\u003ctd\u003eAnnually or sooner, on schedule\u003c\/td\u003e\n\u003ctd\u003eA spent carbon bed can release previously adsorbed hydrocarbon back into the air stream. Never run one past its interval.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eWhy Element Replacement Matters\u003c\/h2\u003e\u003cp\u003eA compressed-air filter is a consumable system, not a permanent fitting. The housing lasts decades; the element does not. Running past the change interval costs money in three separate ways. First, pressure drop: every psid of drop across a loaded element burns roughly 1% of your compressor's horsepower, every hour it runs. Second, contamination breakthrough, where a saturated coalescing element re-entrains the oil it collected and delivers it downstream at full concentration. Third, scrap and rework, when that oil reaches a paint booth, a pneumatic instrument or a food-contact line. An annual element change is among the cheapest reliability spend in a compressed-air system.\u003c\/p\u003e\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\u003cp\u003eScheduled maintenance on Champion FRL Series filters at machine inlets, tool drops, air-motor feeds and pneumatic control panels. Keep a spare set of each grade on the shelf so a planned shutdown is never held up waiting on a filter element.\u003c\/p\u003e\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\u003cp\u003eAir Compressor Store is an authorized Champion Pneumatic distributor. These are genuine Champion elements, not aftermarket equivalents, and they carry the full factory warranty. Our compressed-air engineers can confirm fitment from your filter model number if you are not sure which element you need.\u003c\/p\u003e\u003ch2\u003eAlso Available by Quote\u003c\/h2\u003e\u003cp\u003eChampion prices four elements in this family on a consult-factory basis, so they are not listed for direct purchase: \u003cstrong\u003eCMSP-95-991\u003c\/strong\u003e (0.5 micron, 03 Series), \u003cstrong\u003eCMTP-95-547\u003c\/strong\u003e (0.01 micron, 03 Series), \u003cstrong\u003eCMXP-95-054\u003c\/strong\u003e (carbon, 03 Series) and \u003cstrong\u003eCMXP-95-532\u003c\/strong\u003e (carbon, 30 Series). Call us for current pricing and lead time.\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eHow do I find the right element for my filter?\u003c\/h3\u003e\u003cp\u003eUse the cross-reference chart above: find your filter's model number in the right-hand column and the element part number is on the same row. If the model plate on your filter is unreadable, send us a photo of the unit and the port size and we will identify it.\u003c\/p\u003e\u003ch3\u003eCan I fit a tighter element in the same housing?\u003c\/h3\u003e\u003cp\u003eWithin the CM Series bodies, the S, T and X elements are physically interchangeable, so a CM16 body will accept a 0.5 micron, 0.01 micron or carbon element. What you cannot do is put a CM element in a CF housing or the reverse. Bear in mind that a tighter element in the same body means lower flow capacity and higher pressure drop, so re-check your sizing before you change grade.\u003c\/p\u003e\u003ch3\u003eWhy does my coalescing element look clean but my air is still oily?\u003c\/h3\u003e\u003cp\u003eThat is the classic symptom of a saturated coalescing element. Coalescing media fails by filling with oil, not by visibly clogging, and a saturated element re-entrains oil downstream while looking perfectly serviceable. Change coalescing elements on a calendar schedule, not on inspection.\u003c\/p\u003e\u003ch3\u003eDo I need to depressurize before changing an element?\u003c\/h3\u003e\u003cp\u003eYes. Isolate and vent the filter before opening the bowl. The Champion quick-disconnect bowl has a safety warning latch that vents residual pressure, but that is a backstop, not a substitute for proper lockout.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"CFRP-95-235 - 5 Micron, 03 Series","offer_id":67531326488851,"sku":"CFRP-95-235","price":45.36,"currency_code":"USD","in_stock":true},{"title":"CFRP-95-160 - 5 Micron, 16 Series","offer_id":67531326521619,"sku":"CFRP-95-160","price":31.59,"currency_code":"USD","in_stock":true},{"title":"CFRP-95-115 - 5 Micron, 26 Series","offer_id":67531326554387,"sku":"CFRP-95-115","price":31.59,"currency_code":"USD","in_stock":true},{"title":"CFRP-95-209 - 5 Micron, 30 Series","offer_id":67531326587155,"sku":"CFRP-95-209","price":55.08,"currency_code":"USD","in_stock":true},{"title":"CMSP-95-988 - 0.5 Micron, 16 Series","offer_id":67531326619923,"sku":"CMSP-95-988","price":42.12,"currency_code":"USD","in_stock":true},{"title":"CMSP-95-989 - 0.5 Micron, 26 Series","offer_id":67531326652691,"sku":"CMSP-95-989","price":70.47,"currency_code":"USD","in_stock":true},{"title":"CMSP-95-992 - 0.5 Micron, 30 Series","offer_id":67531326685459,"sku":"CMSP-95-992","price":83.43,"currency_code":"USD","in_stock":true},{"title":"CMTP-95-548 - 0.01 Micron, 16 \u0026 26 Series","offer_id":67531326718227,"sku":"CMTP-95-548","price":83.43,"currency_code":"USD","in_stock":true},{"title":"CMTP-95-551 - 0.01 Micron, 30 Series","offer_id":67531326750995,"sku":"CMTP-95-551","price":195.21,"currency_code":"USD","in_stock":true},{"title":"CMXP-95-987 - Carbon, 16 \u0026 26 Series","offer_id":67531326783763,"sku":"CMXP-95-987","price":140.13,"currency_code":"USD","in_stock":true}]},{"product_id":"champion-dri-series-point-of-use-water-remover","title":"Champion DRI Series Point-of-Use Water Remover – 99% Inline Water Removal (53–424 CFM)","description":"\u003cp\u003eA dryer at the compressor does not guarantee dry air at the tool. Long runs, cold bays, dead legs and overnight shutdowns all put liquid water back into a line that left the dryer dry, and that water reaches the paint gun, the air motor or the blast pot before anything else does. The \u003cstrong\u003eChampion DRI Series water remover\u003c\/strong\u003e is the last line of defence: a point-of-use housing with an element built for one job, pulling \u003cstrong\u003e99% of the water droplets\u003c\/strong\u003e out of the air immediately upstream of the drop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose your port size from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eThread\u003c\/th\u003e\n\u003cth\u003eFlow\u003c\/th\u003e\n\u003cth\u003eReplacement Element\u003c\/th\u003e\n\u003cth\u003eMounting Bracket\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WR-50-08F\u003c\/td\u003e\n\u003ctd\u003e1\/2 in NPT\u003c\/td\u003e\n\u003ctd\u003e53 CFM\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRE-50\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRB-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WR-75-12F\u003c\/td\u003e\n\u003ctd\u003e3\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e78 CFM\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRE-75\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRB-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WR-100-16F\u003c\/td\u003e\n\u003ctd\u003e1 in NPT\u003c\/td\u003e\n\u003ctd\u003e131 CFM\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRE-100\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRB-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WR-150-24F\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003ctd\u003e212 CFM\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRE-150\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRB-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WR-200-32F\u003c\/td\u003e\n\u003ctd\u003e2 in NPT\u003c\/td\u003e\n\u003ctd\u003e424 CFM\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRE-200\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRB-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSize by the \u003cstrong\u003eflow actually passing the drop\u003c\/strong\u003e, not by the pipe thread you happen to have. Undersizing raises velocity through the element, and a water separator that is run too fast re-entrains what it just knocked out.\u003c\/p\u003e\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eAir enters the housing and is forced to change direction and slow down. Liquid droplets, being roughly eight hundred times denser than the air carrying them, cannot follow the turn. They strike the element, coalesce into larger drops, run down the wall of the bowl and collect in the sump, where the drain takes them out of the system. There is no media to blind off and no pressure drop penalty that climbs with hours the way a coalescing filter's does.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e99% removal of inline water droplets\u003c\/strong\u003e, which is Champion's own published figure for the DRI element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempered sight glass\u003c\/strong\u003e so an operator can see water being caught without opening anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-life element\u003c\/strong\u003e, replaceable, not a disposable cartridge on a short service clock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtruded aluminum body\u003c\/strong\u003e, so it survives a knock in a working bay.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThis is a water remover, not a dryer and not an oil filter.\u003c\/strong\u003e It takes out liquid water that is already in the line. It does not lower dew point, so it will not stop water condensing further downstream if the air is still saturated, and it is not a substitute for a \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-dryers\"\u003erefrigerated or desiccant dryer\u003c\/a\u003e. It is also not a coalescing oil filter; for oil aerosol removal use a Grade E or Grade F \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filters\"\u003ecoalescing filter\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003ePoint-of-use or inline liquid water removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Removal Efficiency\u003c\/td\u003e\n\u003ctd\u003e99% of inline water droplets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Sizes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4, 1, 1-1\/2 and 2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e53 to 424 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eExtruded aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndication\u003c\/td\u003e\n\u003ctd\u003eTempered sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement\u003c\/td\u003e\n\u003ctd\u003eReplaceable long-life water removal element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eOptional bracket with position grooves, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification note.\u003c\/strong\u003e Champion's August 2026 price list and the DRI Products performance sheet publish thread size, flow and list price only. Neither document gives a maximum working pressure, a temperature range, a dimensional drawing or a shipping weight for these units, so none is stated here and no catalog weight is carried on these variants. We will not borrow figures from a similar housing and present them as Champion's. If you need a pressure rating or a drawing signed off before you order, ask us and we will get it from the factory, which matters on this page because DRI products are non-returnable.\u003c\/p\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp\u003ePaint and finishing drops, sandblast and abrasive media feeds, plasma cutting tables, air motors and air tools in unheated bays, instrument and control drops on long branch runs, the end of any main that runs through an outside wall or an unconditioned space, and any point of use that is physically far from the dryer.\u003c\/p\u003e\n\u003ch2\u003eService and Replacement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-replacement-water-remover-element\"\u003eDRI replacement water remover elements, XCDI-WRE-50 through XCDI-WRE-200\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-water-remover-mounting-bracket\"\u003eDRI mounting brackets, XCDI-WRB-3 through XCDI-WRB-7\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-drop-assembly\"\u003eComplete DRI drop assemblies\u003c\/a\u003e, which combine the water remover with a lockable isolation valve and a four-port manifold\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-lockable-exhausting-safety-valve\"\u003eLockable exhausting safety valve\u003c\/a\u003e to isolate and bleed the drop for service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLegacy Part Numbers\u003c\/h2\u003e\n\u003cp\u003eChampion's 2015 DRI literature used an entirely different numbering scheme, and customers still quote from it. The products are the same; only the numbers changed.\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLegacy Number\u003c\/th\u003e\n\u003cth\u003eCurrent Number\u003c\/th\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDRI-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRVM-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eComplete point of use solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIVM-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-VM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eIsolation and distribution unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIVWR-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRV-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eIsolation and removal unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCWRM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eRemoval and distribution unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSIL-03 \/ CSIL-04\u003c\/td\u003e\n\u003ctd\u003eXCQL-MF-08M \/ XCQL-MF-12M\u003c\/td\u003e\n\u003ctd\u003eMufflers for the exhausting safety valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAlso Available by Quote\u003c\/h2\u003e\n\u003cp\u003eTwo DRI items appear in Champion's own literature but carry no list price in the August 2026 price book, so they are not sold from this page. We can quote either from the factory:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eXCDI-VM-100\u003c\/strong\u003e (legacy CIVM-100), the 1 in isolation and distribution unit rated 383 CFM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC1-AST\u003c\/strong\u003e, the DRI Condensate Catcher Kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll DRI products and accessories are NO CANCEL \/ NO RETURN\u003c\/strong\u003e, stated in bold on Champion's own price list page. Please confirm size and thread before ordering; we are glad to check it with you.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrackets are not included\u003c\/strong\u003e with the bare water remover. Order the matching XCDI-WRB bracket alongside it, or buy a complete drop assembly, which includes mounting hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weights:\u003c\/strong\u003e Champion publishes no weight for the DRI range, so no catalog weight is carried on these variants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\n\u003cp\u003eWe are an authorized Champion Pneumatic distributor and we sell air treatment as a system rather than as line items. Tell us the compressor, the dryer you already have, the length of the run and what the drop feeds, and we will tell you whether you need a water remover, a coalescing filter, a bigger dryer or simply a drain in the right place. On a no-return line that conversation is worth having first.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eI already have a dryer. Why would I need this?\u003c\/h3\u003e\n\u003cp\u003eBecause a dryer controls dew point at the dryer. Air leaving a refrigerated dryer at a 38 F pressure dew point will re-condense anywhere the line falls below that, which in a northern plant means any run through an unheated bay or against an outside wall. The water remover catches the liquid that forms after the dryer, right where the tool is.\u003c\/p\u003e\n\u003ch3\u003eDoes it dry the air?\u003c\/h3\u003e\n\u003cp\u003eNo. It removes liquid water that is already present. It does not change dew point. If you need genuinely dry air, the answer is a correctly sized \u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-dryers\"\u003edryer\u003c\/a\u003e, and the water remover then protects the point of use from whatever condenses downstream of it.\u003c\/p\u003e\n\u003ch3\u003eWill it take out compressor oil?\u003c\/h3\u003e\n\u003cp\u003eNot as a coalescing filter would. It removes bulk liquid, which on a lubricated compressor includes some oil carried with the water, but oil aerosol removal is a job for a Grade E or Grade F coalescing element. On paint and instrument air, run both.\u003c\/p\u003e\n\u003ch3\u003eHow often does the element need changing?\u003c\/h3\u003e\n\u003cp\u003eChampion publishes no fixed interval and calls it a long-life element. In practice you change it when differential pressure climbs or when the sight glass stops showing water being caught in a system you know is wet. Most shops look at it annually.\u003c\/p\u003e\n\u003ch3\u003eWhich size do I order?\u003c\/h3\u003e\n\u003cp\u003eMatch the flow through that drop, then check the thread. A 1 in unit passes 131 CFM; if the drop only ever sees 40 CFM, the 1\/2 in unit is the right product even if the pipe is larger, and a bushing costs less than the oversized housing. If you are not sure what the drop actually flows, send us the tool list and we will work it out.\u003c\/p\u003e\n\u003ch3\u003eCan I return it if I order the wrong one?\u003c\/h3\u003e\n\u003cp\u003eNo. Champion marks the entire DRI range NO CANCEL \/ NO RETURN. Call or email us before ordering if there is any doubt and we will confirm the size with you.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"1\/2 in NPT – 53 CFM","offer_id":67614869422355,"sku":"XCDI-WR-50-08F","price":229.23,"currency_code":"USD","in_stock":true},{"title":"3\/4 in NPT – 78 CFM","offer_id":67614869455123,"sku":"XCDI-WR-75-12F","price":318.33,"currency_code":"USD","in_stock":true},{"title":"1 in NPT – 131 CFM","offer_id":67614869487891,"sku":"XCDI-WR-100-16F","price":410.67,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 in NPT – 212 CFM","offer_id":67614869520659,"sku":"XCDI-WR-150-24F","price":557.28,"currency_code":"USD","in_stock":true},{"title":"2 in NPT – 424 CFM","offer_id":67614869553427,"sku":"XCDI-WR-200-32F","price":1436.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/water-removal.jpg?v=1791199693"},{"product_id":"champion-dri-series-point-of-use-drop-assembly","title":"Champion DRI Series Point-of-Use Drop Assembly – Water Remover, Lockable Valve and 4-Port Manifold","description":"\u003cp\u003eA proper point of use is three things at once: air that is dry where the tool is, a way to lock the drop out before anyone puts a wrench on it, and enough outlets that the next person does not tee into your line with a hose barb. The \u003cstrong\u003eChampion DRI drop assembly\u003c\/strong\u003e is all three, pre-built on one bracket. \u003cstrong\u003eDistribute. Remove. Isolate.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the configuration and port size from the dropdowns above.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eThe Four Configurations\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eWater Remover\u003c\/th\u003e\n\u003cth\u003eLockable Valve\u003c\/th\u003e\n\u003cth\u003e4-Port Manifold\u003c\/th\u003e\n\u003cth\u003eSizes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete Point of Use\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4, 1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation \u0026amp; Distribution\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation \u0026amp; Removal\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4, 1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemoval \u0026amp; Distribution\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eModel Selection Chart\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eThread\u003c\/th\u003e\n\u003cth\u003eFlow\u003c\/th\u003e\n\u003cth\u003eManifold In \u0026amp; Base\u003c\/th\u003e\n\u003cth\u003eManifold Ports\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRVM-50\u003c\/td\u003e\n\u003ctd\u003eComplete point of use\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e53 CFM\u003c\/td\u003e\n\u003ctd\u003e1\/2 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRVM-75\u003c\/td\u003e\n\u003ctd\u003eComplete point of use\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003e78 CFM\u003c\/td\u003e\n\u003ctd\u003e3\/4 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRVM-100\u003c\/td\u003e\n\u003ctd\u003eComplete point of use\u003c\/td\u003e\n\u003ctd\u003e1 in\u003c\/td\u003e\n\u003ctd\u003e131 CFM\u003c\/td\u003e\n\u003ctd\u003e3\/4 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-VM-50\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; distribution\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e168 CFM\u003c\/td\u003e\n\u003ctd\u003e1\/2 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-VM-75\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; distribution\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003e236 CFM\u003c\/td\u003e\n\u003ctd\u003e3\/4 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRV-50\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; removal\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e53 CFM\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRV-75\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; removal\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003e78 CFM\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRV-100\u003c\/td\u003e\n\u003ctd\u003eIsolation \u0026amp; removal\u003c\/td\u003e\n\u003ctd\u003e1 in\u003c\/td\u003e\n\u003ctd\u003e131 CFM\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRM-50\u003c\/td\u003e\n\u003ctd\u003eRemoval \u0026amp; distribution\u003c\/td\u003e\n\u003ctd\u003e1\/2 in\u003c\/td\u003e\n\u003ctd\u003e53 CFM\u003c\/td\u003e\n\u003ctd\u003e1\/2 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRM-75\u003c\/td\u003e\n\u003ctd\u003eRemoval \u0026amp; distribution\u003c\/td\u003e\n\u003ctd\u003e3\/4 in\u003c\/td\u003e\n\u003ctd\u003e78 CFM\u003c\/td\u003e\n\u003ctd\u003e3\/4 in in; 1\/2 in out\u003c\/td\u003e\n\u003ctd\u003e4 x 1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the isolation and distribution units flow so much more.\u003c\/strong\u003e XCDI-VM-50 is rated 168 CFM against 53 CFM for the same thread size on the other three. That is not a misprint. The VM units have no water remover element in the path, so nothing is restricting them; the 53 and 78 CFM figures are the element's rating, not the pipe's.\u003c\/p\u003e\n\u003ch2\u003eWhat Each Part Does\u003c\/h2\u003e\n\u003ch3\u003eDistribute: Ultra-Flex Manifold\u003c\/h3\u003e\n\u003cp\u003eFour separate outlet points off one block, with threaded inlet and base ports so the manifold can be fed from either end and daisy-chained. Extruded aluminum body, mounting bracket with position grooves. Supplied with three 1\/2 in NPT plugs so you open only the ports you need and the rest stay sealed.\u003c\/p\u003e\n\u003ch3\u003eRemove: Water Remover\u003c\/h3\u003e\n\u003cp\u003eThe DRI element captures water droplets mid-flow and achieves a \u003cstrong\u003e99% water removal rate\u003c\/strong\u003e. A tempered sight glass shows water being caught without opening the housing. This is the same unit sold on its own as the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-water-remover\"\u003eDRI water remover\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eIsolate: Lockable Exhausting Valve\u003c\/h3\u003e\n\u003cp\u003eAn \u003cstrong\u003eOSHA-compliant lockable isolation valve\u003c\/strong\u003e that shuts the drop and exhausts the trapped air downstream of it. Residual pressure in a hose is what fires a fitting across a shop when someone cracks a line they thought was dead, and a plain ball valve does not solve it because the air stays trapped on the tool side. This valve vents it. The same valve is sold on its own as the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-lockable-exhausting-safety-valve\"\u003elockable exhausting safety valve\u003c\/a\u003e, and mufflers are available for it.\u003c\/p\u003e\n\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Sizes\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4 and 1 in NPT depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e53 to 236 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManifold Outlets\u003c\/td\u003e\n\u003ctd\u003eFour, 1\/2 in NPT, with threaded inlet and base ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eExtruded aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Removal Efficiency\u003c\/td\u003e\n\u003ctd\u003e99% of inline water droplets, on water remover configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOSHA-compliant lockable exhausting valve, on isolation configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied With\u003c\/td\u003e\n\u003ctd\u003eThree 1\/2 in NPT manifold plugs on manifold configurations; mounting brackets per configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification note.\u003c\/strong\u003e Champion's August 2026 price list and the DRI Products performance sheet publish thread, flow, manifold porting and list price only. Neither gives a maximum working pressure, a temperature range, dimensions or a shipping weight, so none is stated here and no catalog weight is carried on these variants. We will not borrow figures from a comparable assembly and present them as Champion's. Ask us and we will get a rating or a drawing from the factory before you order, which matters here because DRI products cannot be returned.\u003c\/p\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp\u003eWorkstation and bench drops, paint and finishing booths, maintenance bays, weld cells, assembly lines where several tools share one drop, mobile service rigs, and any drop that will be locked out for routine tool changes. The isolation and distribution units suit clean, dry air mains where water is already handled upstream and what you actually need is four outlets and a lockout point.\u003c\/p\u003e\n\u003ch2\u003eBuilding the Rest of the Drop\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-series-aluminum-compressed-air-pipe\"\u003eQuick-Lock aluminum compressed air pipe, 14mm to 63mm\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-saddle-clamp-outlet\"\u003eSaddle clamp outlets\u003c\/a\u003e to take the drop off a live main without cutting it\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-npt-adapter-plug-and-gauge\"\u003eNPT adapters, bushings, plugs and gauges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-quick-coupler\"\u003eQuick couplers and plugs\u003c\/a\u003e for the manifold outlets\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/collections\/condensate-drains\"\u003eCondensate drains\u003c\/a\u003e for the water the remover collects\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-dryers\"\u003eAir dryers\u003c\/a\u003e, which is where the water problem is actually solved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLegacy Part Numbers\u003c\/h2\u003e\n\u003cp\u003eChampion's 2015 DRI literature numbered these units differently and customers still quote from it. Same products, new numbers.\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLegacy Number\u003c\/th\u003e\n\u003cth\u003eCurrent Number\u003c\/th\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDRI-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRVM-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eComplete point of use solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIVM-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-VM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eIsolation and distribution unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCIVWR-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRV-50 \/ -75 \/ -100\u003c\/td\u003e\n\u003ctd\u003eIsolation and removal unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCWRM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eXCDI-WRM-50 \/ -75\u003c\/td\u003e\n\u003ctd\u003eRemoval and distribution unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSIL-03 \/ CSIL-04\u003c\/td\u003e\n\u003ctd\u003eXCQL-MF-08M \/ XCQL-MF-12M\u003c\/td\u003e\n\u003ctd\u003eMufflers for the exhausting valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eAlso Available by Quote\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eXCDI-VM-100\u003c\/strong\u003e (legacy CIVM-100), the 1 in isolation and distribution unit rated 383 CFM. It appears in Champion's DRI performance sheet but carries no list price in the August 2026 price book, so it is not sold from this page. We can quote it from the factory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC1-AST\u003c\/strong\u003e, the DRI Condensate Catcher Kit, same situation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll DRI products and accessories are NO CANCEL \/ NO RETURN\u003c\/strong\u003e, stated in bold on Champion's own price list page. Confirm configuration and thread before ordering; we are glad to check it with you.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManifold plugs:\u003c\/strong\u003e manifold configurations ship with three 1\/2 in NPT plugs so unused outlets stay sealed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e complete point-of-use units include mounting brackets; isolation and distribution units include a bracket on the manifold; isolation and removal and removal and distribution units include a single bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weights:\u003c\/strong\u003e Champion publishes no weight for the DRI range, so no catalog weight is carried on these variants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\n\u003cp\u003eWe are an authorized Champion Pneumatic distributor and we sell compressed air as a system. Tell us what the drop feeds, how far it is from the dryer and whether it gets locked out, and we will tell you which of these four configurations you actually need rather than selling you the biggest one. On a no-return line that is worth five minutes.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the difference between the complete unit and the isolation and removal unit?\u003c\/h3\u003e\n\u003cp\u003eThe manifold. Both have the water remover and the lockable valve; the complete unit adds the four-port Ultra-Flex manifold and the three plugs. If the drop feeds one tool through one coupler, the isolation and removal unit is enough and saves about $60 at list.\u003c\/p\u003e\n\u003ch3\u003eWhy would I buy the isolation and distribution unit with no water remover?\u003c\/h3\u003e\n\u003cp\u003eBecause the water is already handled upstream and what you need at the wall is four outlets and a lockout. It also flows far more air for the same thread, 168 CFM on the 1\/2 in against 53 CFM, because nothing is restricting it.\u003c\/p\u003e\n\u003ch3\u003eIs the lockable valve really an OSHA lockout device?\u003c\/h3\u003e\n\u003cp\u003eChampion publishes it as an OSHA-compliant lockable isolation valve, and it accepts a padlock in the closed position. Whether a given device satisfies your site's energy control procedure is a call for your safety program, not for us; what we can tell you is that it isolates and exhausts rather than just isolating.\u003c\/p\u003e\n\u003ch3\u003eDo I need the muffler?\u003c\/h3\u003e\n\u003cp\u003eOnly for noise. The valve exhausts the trapped downstream air to atmosphere when it closes, and in a quiet bay that is a sharp crack. The mufflers are XCQL-MF-08M for 1\/2 in and XCQL-MF-12M for 3\/4 in and 1 in, listed with our \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-quick-lock-npt-adapter-plug-and-gauge\"\u003eQuick-Lock NPT adapters and accessories\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eCan I add a water remover to a VM unit later?\u003c\/h3\u003e\n\u003cp\u003eYou can plumb one in ahead of it, yes. Our \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-water-remover\"\u003estandalone DRI water remover\u003c\/a\u003e in the matching thread size does exactly that. It will not bolt into the VM assembly as a module, so you are building the drop rather than converting the unit.\u003c\/p\u003e\n\u003ch3\u003eCan I return it if I pick the wrong configuration?\u003c\/h3\u003e\n\u003cp\u003eNo. Champion marks the entire DRI range NO CANCEL \/ NO RETURN. Call or email us first and we will confirm it with you.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"Complete Point of Use – Remover + Valve + Manifold \/ 1\/2 in NPT","offer_id":67614872305939,"sku":"XCDI-WRVM-50","price":439.02,"currency_code":"USD","in_stock":true},{"title":"Complete Point of Use – Remover + Valve + Manifold \/ 3\/4 in NPT","offer_id":67614872338707,"sku":"XCDI-WRVM-75","price":528.93,"currency_code":"USD","in_stock":true},{"title":"Complete Point of Use – Remover + Valve + Manifold \/ 1 in NPT","offer_id":67614872371475,"sku":"XCDI-WRVM-100","price":740.34,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Distribution – Valve + Manifold \/ 1\/2 in NPT","offer_id":67614872404243,"sku":"XCDI-VM-50","price":213.84,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Distribution – Valve + Manifold \/ 3\/4 in NPT","offer_id":67614872437011,"sku":"XCDI-VM-75","price":219.51,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Removal – Valve + Remover \/ 1\/2 in NPT","offer_id":67614872469779,"sku":"XCDI-WRV-50","price":390.42,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Removal – Valve + Remover \/ 3\/4 in NPT","offer_id":67614872502547,"sku":"XCDI-WRV-75","price":483.57,"currency_code":"USD","in_stock":true},{"title":"Isolation \u0026 Removal – Valve + Remover \/ 1 in NPT","offer_id":67614872535315,"sku":"XCDI-WRV-100","price":638.28,"currency_code":"USD","in_stock":true},{"title":"Removal \u0026 Distribution – Remover + Manifold \/ 1\/2 in NPT","offer_id":67614872568083,"sku":"XCDI-WRM-50","price":358.02,"currency_code":"USD","in_stock":true},{"title":"Removal \u0026 Distribution – Remover + Manifold \/ 3\/4 in NPT","offer_id":67614872600851,"sku":"XCDI-WRM-75","price":452.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/files\/DRI.jpg?v=1791199767"},{"product_id":"champion-dri-series-replacement-water-remover-element","title":"Champion DRI Series Replacement Water Remover Element","description":"\u003cp\u003eThe DRI water remover works because of one part: the element that captures water droplets as the air turns through the housing. When it is tired, the housing is just a lump of aluminum in the line. These are the \u003cstrong\u003egenuine Champion DRI replacement elements\u003c\/strong\u003e, one per housing size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the element for your housing from the dropdown above.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eElement Selection Chart\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElement Part Number\u003c\/th\u003e\n\u003cth\u003eFits Water Remover\u003c\/th\u003e\n\u003cth\u003eThread\u003c\/th\u003e\n\u003cth\u003eFlow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRE-50\u003c\/td\u003e\n\u003ctd\u003eXCDI-WR-50-08F\u003c\/td\u003e\n\u003ctd\u003e1\/2 in NPT\u003c\/td\u003e\n\u003ctd\u003e53 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRE-75\u003c\/td\u003e\n\u003ctd\u003eXCDI-WR-75-12F\u003c\/td\u003e\n\u003ctd\u003e3\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e78 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRE-100\u003c\/td\u003e\n\u003ctd\u003eXCDI-WR-100-16F\u003c\/td\u003e\n\u003ctd\u003e1 in NPT\u003c\/td\u003e\n\u003ctd\u003e131 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRE-150\u003c\/td\u003e\n\u003ctd\u003eXCDI-WR-150-24F\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003ctd\u003e212 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXCDI-WRE-200\u003c\/td\u003e\n\u003ctd\u003eXCDI-WR-200-32F\u003c\/td\u003e\n\u003ctd\u003e2 in NPT\u003c\/td\u003e\n\u003ctd\u003e424 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThese elements also serve the water remover built into the \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-drop-assembly\"\u003eDRI drop assemblies\u003c\/a\u003e. Match the element to the thread size of the assembly: a 1\/2 in XCDI-WRVM or XCDI-WRV takes the XCDI-WRE-50, a 3\/4 in takes the XCDI-WRE-75, and a 1 in takes the XCDI-WRE-100.\u003c\/p\u003e\n\u003ch2\u003eShared Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eLiquid water droplet removal element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished Efficiency\u003c\/td\u003e\n\u003ctd\u003e99% of inline water droplets, as installed in the DRI housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life\u003c\/td\u003e\n\u003ctd\u003eChampion publishes it as a long-life element with no fixed interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eChampion DRI water removers and DRI drop assemblies only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification note.\u003c\/strong\u003e Champion's August 2026 price list publishes the part number, the housing it fits and the list price, and nothing else. There is no published media type, micron rating, dimension or shipping weight for the DRI element in any Champion document we have found, so none is stated here and no catalog weight is carried on these variants. If you need a specification sheet before ordering, ask us and we will request it from the factory, which matters on this page because DRI parts cannot be returned.\u003c\/p\u003e\n\u003ch2\u003eWhen to Change It\u003c\/h2\u003e\n\u003cp\u003eThere is no published hour or month interval. In practice there are three signals:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure drop.\u003c\/strong\u003e If the drop across the housing has climbed noticeably, the element is loading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe sight glass goes quiet.\u003c\/strong\u003e In a system you know is carrying water, a sight glass that stops showing water being caught usually means the element has stopped catching it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater downstream.\u003c\/strong\u003e Liquid reaching the tool on a drop that used to stay dry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMost shops put a DRI element on an annual cycle and bring the date forward if the air is wet or the duty is hard. Isolate the drop before opening the housing. The \u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-lockable-exhausting-safety-valve\"\u003elockable exhausting safety valve\u003c\/a\u003e exists to make that step safe, because it bleeds the pressure trapped downstream rather than just shutting the supply.\u003c\/p\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp\u003eRoutine service on paint and finishing drops, blast cabinets, plasma tables, air tool stations and instrument drops running a Champion DRI water remover. Keep one spare per size on the shelf; these are no-return items, so order the size you can confirm.\u003c\/p\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-water-remover\"\u003eDRI point-of-use water removers, XCDI-WR-50-08F through XCDI-WR-200-32F\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-point-of-use-drop-assembly\"\u003eDRI drop assemblies with manifold and lockable valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/products\/champion-dri-series-water-remover-mounting-bracket\"\u003eDRI mounting brackets\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/aircompressorstore.com\/collections\/air-filters\"\u003eChampion CFL and XC Series filter housings and elements\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll DRI products and accessories are NO CANCEL \/ NO RETURN\u003c\/strong\u003e, per Champion's August 2026 price list.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping weights:\u003c\/strong\u003e Champion publishes no weight for DRI elements, so no catalog weight is carried on these variants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Buy from Air Compressor Store\u003c\/h2\u003e\n\u003cp\u003eWe are an authorized Champion Pneumatic distributor, so these are factory elements and not a lookalike with a similar outside diameter. If you have a housing in the shop and are not sure which element it takes, send us a photo of the label and we will identify it before you order.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know which element my housing takes?\u003c\/h3\u003e\n\u003cp\u003eBy the housing part number, which is on the label. XCDI-WR-50-08F takes XCDI-WRE-50, and so on by size. If the label is gone, measure the thread: 1\/2, 3\/4, 1, 1-1\/2 or 2 in NPT maps to the 50, 75, 100, 150 and 200 elements respectively.\u003c\/p\u003e\n\u003ch3\u003eIs there a generic equivalent?\u003c\/h3\u003e\n\u003cp\u003eWe do not sell one and we would not recommend sourcing one on a 99% water removal claim you cannot verify. The element is what the rating is based on.\u003c\/p\u003e\n\u003ch3\u003eHow often should I change it?\u003c\/h3\u003e\n\u003cp\u003eChampion gives no fixed interval and calls it long-life. Change it on rising pressure drop, on water appearing downstream, or annually as a default on a working production drop.\u003c\/p\u003e\n\u003ch3\u003eCan I clean and reuse it?\u003c\/h3\u003e\n\u003cp\u003eNo. Champion publishes no cleaning procedure for the DRI element and it is not sold as a cleanable part. Replace it.\u003c\/p\u003e\n\u003ch3\u003eCan I return an element if I order the wrong size?\u003c\/h3\u003e\n\u003cp\u003eNo. Champion marks the entire DRI range NO CANCEL \/ NO RETURN. Check with us first and we will confirm the size.\u003c\/p\u003e","brand":"Champion","offers":[{"title":"XCDI-WR-50-08F – 1\/2 in, 53 CFM","offer_id":67614873747731,"sku":"XCDI-WRE-50","price":95.58,"currency_code":"USD","in_stock":true},{"title":"XCDI-WR-75-12F – 3\/4 in, 78 CFM","offer_id":67614873780499,"sku":"XCDI-WRE-75","price":147.42,"currency_code":"USD","in_stock":true},{"title":"XCDI-WR-100-16F – 1 in, 131 CFM","offer_id":67614873813267,"sku":"XCDI-WRE-100","price":222.75,"currency_code":"USD","in_stock":true},{"title":"XCDI-WR-150-24F – 1-1\/2 in, 212 CFM","offer_id":67614873846035,"sku":"XCDI-WRE-150","price":332.91,"currency_code":"USD","in_stock":true},{"title":"XCDI-WR-200-32F – 2 in, 424 CFM","offer_id":67614873878803,"sku":"XCDI-WRE-200","price":745.2,"currency_code":"USD","in_stock":true}]}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/3141\/8387\/collections\/Filters_Collection_81847534-6554-404e-8f96-e5153827a99e.jpg?v=1772197425","url":"https:\/\/aircompressorstore.com\/collections\/filtration.oembed?page=2","provider":"Warthog Air Compressor Store","version":"1.0","type":"link"}